Extron Cable Cubby 202 EU Handleiding

Extron Niet gecategoriseerd Cable Cubby 202 EU

Lees hieronder de 📖 handleiding in het Nederlandse voor Extron Cable Cubby 202 EU (4 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 22 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/4
1
IMPORTANT:
Go to www.extron.com for the
complete user guide
, installation
instructions, and specifications.
Cable Cubby 202 ‱ Installation Guide
This guide provides instructions for an experienced installer to install and connect the
Extron Cable Cubby 202 Cable Access Enclosures.
The Cable Cubby units are furniture-mounted enclosures for cable access,
connections, and AC power. Cables that are not in use can be stored out of
the way while remaining connected to the presentation system.
Planning
Check with local and state regulations before
starting the installation:
Ensure that the planned installation complies with building and
electrical codes.
Ensure that the planned installation complies with the Americans with Disabilities
Act or other accessibility requirements.
Check all parts and equipment before installation:
Ensure that all parts are present in each kit.
Ensure that necessary tools and equipment are available for the installation.
Preparing the Table
Cut a hole in the surface where the enclosure will be installed. .Read the following information before making a cut
Determine the best location for the enclosure
Ensure that the location where the Cable Cubby is to be installed is convenient for as many users as possible.
Ensure that the edge on which the lid opens is oriented correctly.
Ensure that there is ample space under the table for cables.
Choose a method for cutting the hole in the table
See the next page for details on cutting the hole in the table.
CABLE CUBBY
Kit Contents
Grommet Plugs
(3) 3/8", (1) 1/4"
AC Cord
Retainer Clip
(Non-US models only)
Cable Grommet Plate
and #4-40 Plate Sc wsre
Cable Cubby 202
Mini AAP and #4-40 Mounting
Screws (US model only)
2
Cable Cubby 202 ‱ Installation Guide (Continued)
Preparing the Cable Cubby
Assemble the cable pass-through plate and (for US models) install a Mini AAP.
Choose one of the following methods for cutting the hole:
Hand Router and Routing Template Jigsaw and Paper Cut-Out Template CNC Wood Router
If using a CNC wood router or
other precise machinery, use the
exact cut-out dimensions (see the
table below).
Visit www.extron.com for Cable Cubby
routing template part numbers and
instructions.
Dimensions and cut-out templates are
available online at www.extron.com.
The opening in the table for the Cable Cubby should be cut only by licensed and bonded craftspeople.
CAUTION: Wear safety glasses when operating power equipment. Failure to comply can result in eye injury.
ATTENTION: Portez des lunettes de sĂ©curitĂ© lorsque vous utilisez l’équipement Ă©lectrique. Ne pas respecter cela peut
conduire à une blessure à l’oeil.
Cut-out Dimensions
User Access
Width
Side Dimension
7.0"
(17.8 cm)
3.25"
(8.3 cm)
3
US models only:
Install a Mini AAP into the
opening by the AC connection.
Connect cables to the AV
Mini AAP if necessary, and
secure the plate using the
provided mounting screws.
2
Insert the assembled plate into the
enclosu and secu the plate, using re re
the included plate screws.
1
Assemble the cable pass-through
plate with your choice of cables.AV
Snap the included hole plugs into
any unused holes.
Cut-O ut Templ ate for the Extr on
Cable Cubby 202
User Access
0.00” (0.00 c m)
0.02 (0.05 c m)
+
Outer Edge of Front Bez el
(Do not cut this line.)
1. Co nfir m the pro duct to be ins tal led .
2. Re mo ve the sur face cut- ou t are a
(gra y) fro m the tem pla te.
3. Me as ure the cutou t and te mpl ate .
4. Ma rk the p os itio n o n the
furn iture wher e the Cabl e Cub by 202
will be ins tal led .
5. Do uble check di me nsi ons and pos itio n,
the n cut the ope nin g.
P/N ??-????-01 R ev. A
Pag e size : 11" x 17"
Print scale 1:1
Do not shrink.
3.25"
(8.25 cm)
7.0"
(17.78 cm)
SURFACE
CUT-OUT
AREA
Cut-Out Radi us :
0.25"
(0.6 cm)
Cut-O u t T
Ca
3
Mounting and Installing the Cable Cubby in the Table
CAUTION: The anged edges of the top of the surface enclosure are sharp. These edges are also soft and may be easily
nicked or bent. Exercise caution when handling the enclosure to prevent personal injury or damage to the enclosure.
ATTENTION: Les extrémités à brides du haut de la surface du boßtier sont aiguisées. Ces extrémités sont aussi lisses
et peuvent facilement ĂȘtre coupĂ©es ou pliĂ©es. Soyez prudents lorsque vous manipulez le boĂźtier an d’éviter de
l’endommager ou de vous blesser.
Lower the Cable Cubby into the hole
to test the t. If necessary, carefully
enlarge the opening.
Remove the plastic strips and lm on the
surface of the Cable Cubby.
Ensure that the side clamps are
seated against the enclosure.
En
se
1
2
3
ATTENTION: When tightening the clamp screws, do not
exceed a torque rating of 5 inch-pounds. Overtightening
can damage the clamp mechanism and enclosure.
ATTENTION: Lors du serrage des pinces Ă  vis, veillez Ă  ne
pas dépasser une valeur de couple de 5 livres par pouce.
Un serrage excessif pourrait endommager le dispositif ainsi
que le boĂźtier.
Ensure that the Cable Cubby is rmly seated in the table.
Using a screwdriver, tu the clamp screw clockwise rn
and slowly tighten it to secu the enclosure to the surface.re
4


Product specificaties

Merk: Extron
Categorie: Niet gecategoriseerd
Model: Cable Cubby 202 EU
Kleur van het product: Zwart
Gewicht: 800 g
Materiaal: Metaal
Code geharmoniseerd systeem (HS): 85389099

Heb je hulp nodig?

Als je hulp nodig hebt met Extron Cable Cubby 202 EU stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Extron

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd