Entes EVM-3C-48 Handleiding

Entes Meetapparatuur EVM-3C-48

Lees hieronder de 📖 handleiding in het Nederlandse voor Entes EVM-3C-48 (2 pagina's) in de categorie Meetapparatuur. Deze handleiding was nuttig voor 27 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/2
VOLTMETER
EVM-3 / EVM-3C
2
Setting of Of Time Valuef
(EVM-3C için)
SET
SET
SET
Setting of On Time Value
(for EVM-3C)
SET
SET
SET
Setting of Hysteresis Value
(for E M-3C)V
SET
SET
SET
020.0
Setting of Instant Tripping Function
(for EVM-3C)
Set
Set
Set
Setting of Latch Function
(for EVM-3C)
Set
Set
Set
Displaying and Deleting Tripping Number (for EVM-3C)
Set
Set
Set
Press UP button to delete tripping
number, else do not press any button.
0002
0000
Press the button for 3 sec.SET
Press or buttons until isUP DOWN hYS
displayed.
Press button.SET
Press or buttons until requestedUP DOWN
value is displayed. (If buttons are pressed
continuously, displayed value is changed
quickly).
Press button to save.SET
Press the button for 3 sec.SET
Press or buttons until isUP DOWN on t
displayed.
Press button.SET
Press or buttons until requestedUP DOWN
value is displayed. (If buttons are pressed
continuously, displayed value is changed
quickly).
Press button to save.SET
Press the button for 3 sec.SET
Press or buttons until isUP DOWN oF t
displayed.
Press button.SET
Press or buttons until requestedUP DOWN
value is displayed. (If buttons are pressed
continuously, displayed value is changed
quickly).
Press button to save.SET
Press the button for 3 sec.SET
Press or buttons until isUP DOWN trP
displayed.
Press button.SET
Press or buttons until requestedUP DOWN
value is displayed. (If buttons are pressed
continuously, displayed value is changed
quickly).
Press button to save.SET
Press the button for 3 sec.SET
Press or buttons until isUP DOWN LAtC
displayed.
Press button.SET
Press or buttons until requestedUP DOWN
value is displayed. (If buttons are pressed
continuously, displayed value is changed
quickly).
Press button to save.SET
Press the button for 3 sec.SET
Press or buttons until isUP DOWN oP
displayed.
Press button.SET
Press button to save.SET
Setting of Low Setpoint Value
(for EVM-3C)
SET
SET
SET
025.0
02 .52
Press the button for 3 sec.SET
Press or buttons until isUP DOWN SP L
displayed.
Press button.SET
Press or buttons until requestedUP DOWN
value is displayed. (If buttons are pressed
continuously, displayed value is changed
quickly).
Press button to save.SET
Setting of Voltage Transformer Primary Voltage Value (for EVM-3C)
SET
SET
SET
0250
02 52
Setting of Voltage Transformer Secondary Voltage Value (for EVM-3C)
SET
SET
SET
0250
02 52
Setting of High Setpoint Value
(for EVM-3C)
250 0.
275 0.
SET
SET
SET
Minimum and Maximum Voltage :
The minimum and maximum voltage values are stored. User may read or delete
these values. Stored minimum and maximum voltage values remain stored,
when the power supply is off.
Setpoint ( s p s p v e ): When the AC current which flows through the device
is over the high setpoint value or it is under the low setpoint value, the output
relay is switched on in order to generate an error signal at the end of programmed
delay time ( The point which is on the below right corner of display blinks). If
the AC current value returns within preset limits, before the end of the delay
time, the relay resets itself and no tripping occurs.
Latch Function ( ) : Latch function is used to select the output relay
operation mode. Either îš“oFîš” or îš“onîš” position may be selected.
At position îš“oFîš”: If the current value returns to preset limits, output relay is
switched off.
At position îš“onîš”: Even if the current value returns to preset limits, output relay
remains switched on and switches off only by pressing the îš“Setîš” button.
Instant Tripping ( ) : If the AC current value is over the1,5 times of setting
value or it is under the 0,5 times of setting value, the output relay is switched
on without any delay time. This function is user-selectable.
Press the button for 3 sec.SET
Press or buttons until isUP DOWN Prý
displayed.
Press button.SET
Press or buttons until requestedUP DOWN
value is displayed. (If buttons are pressed
continuously, displayed value is changed
quickly).
Press button to save.SET
Press the button for 3 sec.SET
Press or buttons until isUP DOWN SEC
displayed.
Press button.SET
Press or buttons until requestedUP DOWN
value is displayed. (If buttons are pressed
continuously, displayed value is changed
quickly).
Press button to save.SET
Press the button for 3 sec.SET
Press or buttons until isUP DOWN SP h
displayed.
Press button.SET
Press or buttons until requestedUP DOWN
value is displayed. (If buttons are pressed
continuously, displayed value is changed
quickly).
Press button to save.SET
EVM-3 (Voltmeter) :
EVM-3 is designed for accurate measuring of the AC RMS voltage and for
saving the minimum and maximum values of the measured voltages. Minimum
and maximum values remain stored in the memory when the power supply is
off. This stored values can be read when the power is on. Although EVM-3 is
mainly used for electrical panels, this device can also be used with any application
in which accurate voltage readings should be done between 10-600V. The
measurement (3-4) and power supply (1-2) connections are located on the rear
panel and the digital display is centered on the front panel.
EVM-3C (Setpointed Voltmeter) :
EVM-3C has the same functions of the EVM-3. In addition to these functions,
an high voltage level and îš“time delayîš” can be set. When the measured voltage
is over the high set point value, the output relay is activated at the end of the
adjusted time delay, generates an alarm signal and display starts blinking.
Note: If the measurement that the device made or the primary value is over
9999 V, k led on the device is on.
Note: If the voltage on the measurement input of the device is over 600 V or
measurement according to the ratio of entered primary/seconder is over 999.000
V, there will be îš“ îš” on the display.
Voltage Transformer Ratio: Voltage transformer can regulate the primary and
secondary voltage values separately. Primary value can be entered between
1-40.000 and the second value can be entered between 1-250.ary
Note: If the primary and secondary values changed, control the setpoint
and hysterisis values. This is important for the device working the way
that it was arranged.
Precautions For Insta llation and Safe Use
Failure to follow those instructions will result in death or serious injury.
Disconnect all power before working on equipment.
When the device is connected to the network, do not remove the front
panel.
Do not try to clean the device with solvent or the like. Only clean the
device with a dried cloth.
Verify correct terminal connections when wiring.
Electrical equipment should be serviced only by your compedent seller.
Only for rack panel mounting.
No responsibility is assured by the manufacturer or any of its
subsidiaries for any consequences arising out of the use of this
material.
VOLTMETER
EVM-3 / EVM-3C
A3986 / Rev.5
2
Warning :
a) A switch or circuit breaker must be connected between the network
and the auxiliary supply input of device.
b) Connected switch or circuit breaker must be in close proximity to the
device.
c) Connected switch or circuit breaker must be marked as the
disconnecting device for the equipment.
d) The type of the used fuse must be FF type and the current of the used
fuse must be 1A.
e) No need of a vantilator in the installation area
f ) Do not use with generator.
* Please check the device label for proper value.
*Different supply voltages are adjustable upon request.
Pcs per Package : 16 Pcs (for PR 18)
Package Weight : 4.5 kg
Pcs per Package : 12 Pcs (for PR )25
Package Weight : 3.6 kg
Pcs per Package : 20 Pcs (for PR 20)
Package Weight : 5 kg
Packaging Information
!
Technical Data
Operating Voltage (Un),*
Operating Range( U) D: Please look at labels on the device.
Operating Frequency(f) : 45-65 Hz
Accuracy : 1% ±1 digit [(%10-%100) full scale]
Measuring Input (Vin) : 0-600 V AC (for EVM-3, EVM-3C)1
Power Consumption(Pcons) : <4 VA
Burden : <1 VA (per phase)
Output Contact : 5 A, 250 V, 1250 VA (Resistive) (for EVM-3C)
Voltage Transformer Ratio
Primary : 1-40000 (for EVM-3C)
Secondary : 1-250 (for EVM-3C)
Ins. Tripping : >1.5 x SPH or <0.5 x SPL (for EVM-3C)
Hysteresis : 0-0.5 x Full scale (for EVM-3C)
Delay Time : 0.0 - 99 .9 sec. (for EVM-3C)9
Enclosure : Non-flammable
Equipment Protection : Double Insulation ( ),
Measuring CategoryIII
Ambient Temperature : -5 OC; +50 OC
Degree of Protection : IP 40 (Front Panel)
Installations : Flush mounting with rear terminals
Wire Cross ection (for terminals): s
2.5 mm2
Dimensions : Type PR 18, PR 25, PR 20
Weight : 0.28 kg (for PR 18)
0.30 kg (for PR 25)
0.25 kg (for PR 20)
Dimensions
The Area Measurements on The Control Panel
TYPE PR 20 (48x96)
Wall
43mm
63mm
54 mm
50mm
90mm
79.3mm
70mm
TYPE PR 25 (96x96)
50mm
Wall
42mm
82.5mm
75mm
TYPE PR 18 (72x72)
50mm
65.5mm
Wall
Control Panel Cut Out
91mm
91mm
TYPE PR 25 (96x96)
66mm
66mm
TYPE PR 18 (72x72) TYPE PR 20 (48x96)
91mm
44mm
TYPE PR 25 (96x96) TYPE PR 20 (48x96)TYPE PR 18 (72x72)
96mm
96mm
96mm
48mm
72mm
72mm
Connection Diagrams
N
1
256
Output
Contact
EVM-3C
(72x72)
L
1A
Measuring
Input
12
1A
L
N
Measuring
Input
EVM-3
(48x96)
34
EVM-3C
(48x96)
N
12
L
1A
3
Measuring
Input
4
56
Output
Contact
65
EVM-3
Slim-96
1A
L
N
4
Measuring
Input
3
65
EVM-3C
Slim-96
1A
L
N
Output
Contact
78
4
Measuring
Input
3
4 3
Deleting the Minimum and Maximum Voltages
Press and buttons at the same time.(for EVM-3C)UP DOWN
Escaping the Set Menu (for EVM-3C)
Set
Factory Setting :
Voltage transformer primary voltage value ( )
Voltage transformer secondary voltage value ( )
High set point value ( )
Low set point value ( )
Hysteresis value ( )
On time ( )
Off time ( )
Instant tripping function ( )
Latch function ( )
Contact situation ( )
: 0100
: 0100
: 250.0
: 150.0
: 010.0
: 010.0
: 010.0
: on
: oF
: no (Normaly open)
Press and hold for two second to delete demands
values. (for EVM-3)
If the button is not pressed again within 20 seconds, EVM-3
turns back automatically in measuring mode. (for EVM-3)
Displaying Maximum Voltage
Press and hold the button to see. (for EVM-3C)UP
Press two time to see the maximum voltage value. (for EVM-3)
Displaying Minimum Voltage
Press and hold the button to see. (for EVM-3C)DOWN
Press one time to see the minumum voltage value. (for EVM-3)
îš• The decimal point blinks while the display shows demand values (for EVM-3).
e s c
If you do not want to change any
adjustment in the menu;
Press or buttons until isUP DOWN ESC
displayed.
Press the button.SET
Setting of Contact Situation
(for EVM-3C)
SET
SET
SET
c
Press the button for 3 sec.SET
Press or buttons until isUP DOWN oUt
displayed.
Press button.SET
Press or buttons until requestedUP DOWN
value is displayed. (If buttons are pressed
continuously, displayed value is changed
quickly).
Press button to save.SET
N
1
2
EVM-3
(72x72)
L
1A
Ölçüm
Giriþi
4 3


Product specificaties

Merk: Entes
Categorie: Meetapparatuur
Model: EVM-3C-48

Heb je hulp nodig?

Als je hulp nodig hebt met Entes EVM-3C-48 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Meetapparatuur Entes

Handleiding Meetapparatuur

Nieuwste handleidingen voor Meetapparatuur