EMOS MD-110 Handleiding

EMOS Multimeter MD-110

Lees hieronder de 📖 handleiding in het Nederlandse voor EMOS MD-110 (88 pagina's) in de categorie Multimeter. Deze handleiding was nuttig voor 36 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/88
2202014000_31-M0320_00_01 90 × 130 mm
www.emos.eu
M0320 | MD-110
GB Digital Multimeter
CZ Digitální multimetr
SK Digitálny multimeter
PL Multimetr cyfrowy
HU Digitális multiméter
SI Digitalni multimeter
RS|HR|BA|ME Digitalni multimetar
DE Digitales Multimeter
UA Цифровий мультиметр
RO Multimetru digital
LT Skaitmeninis multimetras
LV Digitālais multimetrs
EE Digitaalne multimeeter
BG Цифров мултиметър
2
1
GB | Digital Multimeter
Before you start using MD-110 read carefully this manual.
Especially important passages that deal with principles of safety work with this device
are highlighted. You will prevent electric shock or damage of the device. The digital
multimeter was designed in accordance with standard IEC-61010 relating to electronic
measuring instruments falling in to the category (CAT III 300 V), pollution level 2. The
CAT III category is used to measure circuits powered by a xed output power supply,
such as a relay, socket, switchboards, power supplies, short branching circuits and
lighting systems in large buildings.
Electrical symbols
Alternating current (AC)
Direct current (DC)
Alternating/direct current (AC/DC)
WARNING - Read up the instructions before using this device
Risk of electric shock
Ground
Safety-fuse
Declaration of Conformity (CE)
The device is protected by a double insulation and a reinforced insulation
CAUTION
Pay special attention to the following instructions:
Carefully check that the device is not damaged before you start using the
multimeter. If you see any obvious damage of the device, do not perform any
measurement! Check if the surface of the multimeter is not scratched and side
connections are not unglued.
Check the insulation of the measuring probes and jaws. There is a risk of electric
shock when the insulation is damaged. Do not use the damaged probes!
3
Do not measure voltages higher than 300 V or current higher than 200 mA!
Do not measure current, if the void voltage in an open circuit is higher than 300 V.
The „COMterminal must always be connected to the reference measuring ground.
If you detect abnormal measurement results, do not use the multimeter. If you are
not sure about the cause of a failure, contact the service center.
Do not measure higher voltages and currents than those indicated on the front
panel of the multimeter. There is a risk of electric shock and damage of the
multimeter!
Verify that the multimeter is working properly before use. Test a circuit where you
know its electrical parameters.
Turn o the power supply of the circuit before you connect the multimeter to the
circuit of which current you intend to measure to.
Do not use or store the multimeter in environments with high temperature, dust
and moisture. It is also not recommended to use the device in an environment
where a strong magnetic eld is present or where there is a risk of explosion or a re.
When replacing the battery or other parts of the multimeter, use spare parts of
the same type and specication. Replace the parts only when the multimeter is
switched o and disconnected!
Do not change or modify the internal circuits of the multimeter!
Caution when measuring voltages higher than 30 V AC rms, 42 V peak or 60 V
DC. Risk of electric shock!
When handling the measuring pins make sure to hold them behind the nger
barrier.
To avoid electric shock, do not touch any bare wires with your hands or skin.
Disconnect the measuring pins from the circuit before opening the cover of the
multimeter.
Do not take any measurements if the cover of the multimeter is removed or it
is loose.
When the display shows a discharged battery icon „ , replace the battery.
Otherwise, the subsequently performed measurements can be inaccurate. This
can lead to biased results of the measurement resulting in an electric shock!
WARNING
Use a multimeter MD-110 only as specied below, otherwise it may result in damage
of the device or your health. Pay attention to the following instructions:
Disconnect circuits from their power source and discharge high-voltage capacitors,
before you make any measurement of resistance, diode or current.
Check if a round range selector switch knob is in the correct position before
measurement. Do not make any changes in the measuring range (by turning
the round range selector switch knob) during the measurement in any case! This
could cause damage of the device.
When measuring current, turn o the power supply of circuit before you connect
the multimeter.
Description of the device
Digital multimeter MD-110 belongs to a series of compact devices with 3.5 digital
display, designed to measure AC and DC voltage, DC current, resistance and diode


Product specificaties

Merk: EMOS
Categorie: Multimeter
Model: MD-110

Heb je hulp nodig?

Als je hulp nodig hebt met EMOS MD-110 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Multimeter EMOS

Handleiding Multimeter

Nieuwste handleidingen voor Multimeter