Elro EC11 Handleiding


Lees hieronder de πŸ“– handleiding in het Nederlandse voor Elro EC11 (2 pagina's) in de categorie Smarth home. Deze handleiding was nuttig voor 98 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/2
1
Wireless Energy Meter
The instruments are designed to provide accurate and reliable measurements.Before setting up the meter,please read these
instructions carefully.
Main set function:
The main set work on battery,can be put on an indoor desktop, it can display datas as the following:
1. Display current clock.
2. Display temperature and humidity.
3. Display line voltage.
4. Display line current.
5. Display line power.
6. Display and memory each channel accumulative Kwh.
7. Display and memory greenhouse gas emossion.
8. Display and memory accumulative total Kwh..
9. Display and memory total on time and total electric charge.
10. Display and memory total on time and total electric charge of price1.
11. Display and memory total on time and total electric charge of price2.
12. Receive max. 3 channel wireless remote transmitter.
Transmitte set function:
The transmitter acquisition voltage, current, power and transmitt them to main set,then display on main set. Plug the remote
transmitter into power socket, then plug an appliance into the transmitter. The transmitter can transmit up to 30 meters without outside
interference(e.g. metal surface,electrical device,ect).
I. Key
MODE key
SET key
PRICE key
CODE key
UP key
CLR key
CLK/ARM key
II. Operating instruction
1. Choice of display mode:
(1)Press key,the data display line voltage,line current,line power,Kwh,greenhouse gas emossion. MODE
(2)Press key,the data display accumulative total Kwh, total on time and total electric charge of price1, total on time and total PRICE
electric charge of price2.
2. Clock set
Press key for over 3 seconds to set week firstly,press key to set week;then Press key to set hour, press key to set SET UP SET UP
hour; then Press key to set minute, press key to set minute,comeback clock display mode if no key-press operation is SET UP
performed after 15 seconds or press key.CLK/ARM
3. Clock alarm set
Press key under clock display mode to enter alarm display mode. Press key to set hour first, press CLK/ARM SET UP key to set hour;
then Press key to set minute, press key to set minute. Return to clock display at press of key, and icon β€œ ” will SET UP CLK/ALM
display and flicker if alarm is set.
Alarm starts at appointed time: when alarm starts at appointed time, buzzer will give off β€œBEEP” sound and stops after 60 seconds;
press any key to stop alarm within 60 seconds. Press key to cancel alarm during alarm setting. CLR
4. Price set
Press key once and release,Then press and hold key for 5 seconds during display state of total Kwh or price.PRICE PRICE
(1). Setting price : 1
(a). Press key once and release, display, the first digital flash, press button to set it. SET SET COST/kWh UP
(b). Press key once again and release, the second digital flash, press button to set it. SET COST/kWh UP
(c). Press key once again and release, the third flash, press button to set it. SET COST/kWh UP
(d). Press key once again and release, the fourth flash, press button to set it. SET COST/kWh UP
(e). Press key once again and release, the radix point flash, press button to set it. SET COST/kWh UP
(f). Press key once again and release, the weekday flash, press button to set it. SET UP
(g). Press key once again and release, the hour of flash, press button to set it. SET ON TIME UP
(h). Press key once again and release, the minute of flash, press button to set it. SET ON TIME UP
(2). Setting price : 2
2
Press key once and release after finish Setting price 1. Setting price 2, repeat above steps. PRICE
5. Max load alarm set
Long press key under current ( ) display mode to enter Max load alarm set. Press the Max load will flash,PressMODE AMP SET UP
key to set Max load alarm.The buzzer will give off β€œBEEP” sound and MAX LOAD will flash the when the load exceed the setting load,
The buzzer will stop and MAX LOAD will stop flash untill the load less than the setting load.
6. The scale of to set KG GAS/KWH
Long press key under display mode to enter scale of set. Press key the MODE KG GAS/KWH KG GAS/KWH SET KG GAS/KWH
will flash,Press key to set Max load alarm. UP
The scale of you can inquire department of energy. KG GAS/KWH,
7. Channel-select
Channel-select: conduct channel-select for 1,2 or 3 remotes before using them.Channel-select steps:
(1)Load main set battery,long press the key,1CODE
st
channel-select,wireless reception displays1 β€œ- -:- -”.Plug the 1
st
remote
transmitter into power socket, long press the key after the LED of transmitter flash six time automatic,the 1 will display the electrical SET
data if channel-select succeed.
(2)Short press the key again, enter the 2CODE
nd
channel-select, long press the key,wireless reception displays2 β€œ- -:- -”.Plug CODE
the 2
nd
remote transmitter into power socket, long press the key after the LED of transmitter flash six time automatic,the 2SET
will
display the electrical data if channel-select succeed.
(3)Short press the key again, enter third channel-select, long press the key,wireless reception displays 3 β€œ- -:- -”.Plug CODE CODE
the third remote transmitter into power socket, long press the key after the LED of transmitter flash six time automatic,the 3 will SET
display the electrical data if channel-select succeed.
Then you can place the main set up to 30m away from the remoet set.
Corresponding data( ) will display as follow when failing to receive the remote data ,Most of the time the unit will repeating 000
receive the remote signal till the correct data displays.However,if corresponding data( ) continue to occur, the following may also be 000
the reason:
(a).The main set has been placed outside of the effective transmission range( more than 30 meters).Please move the main set closer
to the remote set.
(b).The remote may have outside interference that is preventing proper transmission.Sources of the interference include but are not
limited to metal surfaces,electrical devices,ect. The remote may need to be relocated if interference continues.
(c).Low battery.Please change the battery if it used for too long time, repeat the step (1), (2), (3) to reselect channel after
change battery.
III. Care of the product
Wipe off any dirt using a soft cloth, dipped in mild detergents, wipe off any dirt using a soft dry cloth,Avoid placing the uints in
prolonged direct sun,wind chill,rain or high humidity-position.Secure the uints to avoid dorpping-excessive force which will permanently
damage the uints.Do not tamper with the internal components.Always read the instructions in full before operating the uints.Failure to
follow these care guidelines will invalidate the warranty on the uints.
IV. Technical features
1 Indoor Testing temperature scope -10
o
C ~ +40
o
C
2 Testing temperature precision +/-1
o
C
3 Testing humidity scope 30%RH ~ 95%RH
4 Testing humidity precision +/-5% in the range of 40%~80%
+/-8% in the range of 30%~40% or 80%~95%
5 Clock precision +/-1minute/month
6 Wireless transmission and reception frequency RF433.92MHz
7 Effective distance of wireless transmission and reception Maximum 30M in open space
8 Main set power supply 4.5V(3 pieces AA/UM3/LR6 size 1.5V battery)
9 Battery life about 3 months without AC power
10 Remote power supply 230V/50Hz
11 Measure voltage range 190-276V AC
12 Measure voltage accuracy +/-1%
13 Measure current range 0.02-16A
14 Measure current accuracy +/-1% or +/-0.01A
15 Measure power range 0.5-4416W
16 Measure power accuracy +/-1% or +/-0.5W
17 Accumulative electric quantity range 0 -9999.9Kwh
18 Greenhouse gas emossion range 0 -9999.9KG
EMG-2T,EMF-2T, EMD-2T,EMI-2T,EMIS-2T/EM-2R


Product specificaties

Merk: Elro
Categorie: Smarth home
Model: EC11

Heb je hulp nodig?

Als je hulp nodig hebt met Elro EC11 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Smarth home Elro

Handleiding Smarth home

Nieuwste handleidingen voor Smarth home