Elektrobock BT52 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Elektrobock BT52 (20 pagina's) in de categorie Thermostaat. Deze handleiding was nuttig voor 22 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/20
1
B
B
B
BT52
T52
T52
T52
BT52
WIRELESS ROOM THERMOSTAT
for boilers with OpenTherm communication
The BT52 wireless thermostat is designed to control gas and electric boilers that use the OpenTherm plus (OT +) commu-
nication protocol. It consists of a receiving part (receiver) and a transmitting part (transmitter), which use two-way wireless
communications on the frequency of 433.92 MHz. This wireless variant allows for easy and quick installation, thus eliminating
the laborious and time-consuming installation of the line between the thermostat and the boiler with a passage through the
oor. The receiver is connected to the boiler via the OT communication line. This line transmits data and also powers the rece-
iver. The receiver immediately transmits the data obtained from the boiler to the transmitter, where the data is processed. The
required heating water is calculated and this request is sent back to the boiler.
receiver
transmitter
• Possibility to place a thermostat (transmitter) as needed.
• Predictive system (smart timer) guarantees determined
temperature at the required time. The adaptive controller evaluates
temperature gradient of the room and can determine the necessary
time to reach the required temperature.
9 weekly programs (optional) for UT (6 temperature changes
for a day).
• 1 week program (optional) for DHW (3 time periods
with dierent temperatures).
• Choice of regulation type:
equithermal regulation
equithermal control with internal temperature correction
PI regulation
• Display of operating hours information for UT / TUV.
• Display of outdoor temperature information.
Display of heating water temperature and modulation power in-
formation.
• Display of additional information sent by the boiler to the receiver
(water ow in liters, return temperature, etc. depending on the type
boilers).
• E-EPROM memory retains all settings indenitely
even in the event of a power failure.
• Possibility of control via GSM module GST1 or GST2 (optional).
• Automatic changeover to WINTER or SUMMER time.
• Automatic indication of boiler maintenance.
• Measured temperature -9 ° C to 39 ° C.
• Antifreeze mode.
• Holiday mode and summer mode.
• Power supply 2x1.5 V alk. battery
Power supply via OT communication
line directly from the boiler (or external
adapter AD05 - not included)
Receiver with SELF-LEARNING system
CODES and with E-EPROM memory (sto-
re code even in case of power failure).
Visual inspection of conditions
using colored indicator LEDs.
The receiver keeps the last settings
and in the event of a wireless failure
signal, ensures the operation of the boiler.
ca 25 m
BOILER
with OpenTherm
communications
over one
oor
2
CONTENT
Description BT52 ............................................................... .1p
Content ............................................................... .2p
Properties BT52 ............................................................... .3p
Function .......................................................... p.3
Commissioning diagram .......................................................... p.3
Receiver BT52 ............................................................... .4p
Assembly .......................................................... p.4
Wireless mode .......................................................... p.5
Receiver coding .......................................................... p.5
Transmitter BT52 ............................................................... .6p
Description of controls .......................................................... p.6
Battery placement .......................................................... p.6
Transmitter disassembly .......................................................... p.6
Display description .......................................................... p.7
Operating modes (AUTO, MANU ..) .......................................................... p.8
Setting of temperature programs for UT and TUV .......................................................... p.9
Table of free and preset programs .......................................................... p.9
Setting constants CONST1 to CONST7 .......................................................... p.10
CONST1 Language selection ..................................................................... .10p
CONST2 Minimum regulated temperature ..................................................................... .10p
CONST3 Maximum regulated temperature ..................................................................... .10p
CONST4 Minimum water temperature in the heating system ..................................................................... .10p
CONST5 Maximum water temperature in the heating system ..................................................................... .10p
CONST6 Choice of regulation type ..................................................................... .10p
CONST7 PI control interval ..................................................................... .10p
Setting the CONST8 constant .......................................................... p.11
CONST8 Proportional band of PI regulation ..................................................................... .11p
Setting constants CONST9 to CONST12 .......................................................... p.12
CONST9 Manual or automatic heating curve correction .................................................................... .12. p
CONST10 Building insulation ...................................................................... .12p
CONST11 Equithermal control interval ...................................................................... .12p
CONST12 Equithermal control reaction rate ...................................................................... .12p
Setting constants CONST13 to CONST20 .......................................................... p.13
CONST13 Premature heating on ...................................................................... .13p
CONST14 Summer mode ...................................................................... .13p
CONST15 Odd - even week choice ...................................................................... .13p
CONST16 Temperature correction ...................................................................... p.13
CONST18 Choice of control via GSM module ...................................................................... .13p
CONST19 Phone number setting ...................................................................... .13p
CONST20 Setting the PIN code of the used SIM card ...................................................................... .13p
Setting constants CONST21 to CONST27 .......................................................... p.14
CONST21 Function test ...................................................................... .14p
CONST22 Key lock ...................................................................... .14p
CONST23 Key code ...................................................................... .14p
CONST24 Boiler maintenance indication ...................................................................... .14p
CONST26 Boiler type selection ...................................................................... .14p
CONST27 Password (against setting change) ...................................................................... .14 p
Other displayed information .......................................................... p.15
Error messages .......................................................... p.16
Antifreeze mode .......................................................... p.16
GSM module connection .......................................................... p.16
Control when using the GSM module .................................................................. p.17
Technical parameters ......................................................... p.18
For easier orientation in the manual, each page is marked with the symbol of the part of the thermostat to
which it applies specied settings:
RECEIVER TRANSMITTER
3
BT52 FEATURES
Before using the thermostat, it is necessary to verify which functions from the OpenTherm protocol your
heating device uses (some heating devices do not use all the functions of the OpenTherm protocol)!
OpenTherm Plus / Lite (OT + / OT-) protocol: based on this protocol, two-way communication (OT +) takes place
between the thermostat receiver and the boiler. The thermostat receiver obtains the necessary information (eg
about the outdoor temperature), which it then processes and transmits to the transmitter. From the information
obtained about the outdoor temperature, the room temperature and the set constants, the thermostat recalculates
the desired water temperature of the heating system and passes it back to the boiler. This wireless communication
system enables optimal operation of the boiler and heating system, including DHW, thus achieving longer boiler
life and higher savings.
In order to avoid interference and inuence from other BT52s in the vicinity, each thermostat is protected
by its own unique code, which is stored at the factory! As the whole system works on the two-way radio fre-
quency 433.92 MHz, follow the instructions for mounting and positioning the thermostat according to the
instructions!
!BT52 FUNCTIONS
Equithermal regulation
Equithermal control with manual curve correction
Equithermal control with automatic correction according to the eect of room temperature
Correction of the inuence of building dynamics (for equithermal regulation)
PI control (regardless of outdoor temperature)
Premature heating on (adaptive controller evaluates the room temperature gradient
and can determine the time necessary to reach the desired temperature at a given time)
Setting the minimum and maximum water temperature in the heating system
DHW preparation program (3 time intervals per day)
Holiday mode (constant temperature during the holiday)
Summer mode
COMMISSION SCHEME BT52
STUDY MANUAL
BT52
p.1-18
RECEIVER ASSEMBLY
BT52
p.4
TRANSMITTER
RECOVERY
p.6
BT52 TRANSMITTER FUNCTION
SETTINGS p.7-17
WIRELESS MODE SETTINGS
p.5
TRANSMITTER CONTROL
BT52
p.8-17
SERVICE
TECHNICIAN
USER
Follow the instructions to install the receiver and
connect via the communication line to the boiler
(or connect an external adapter).
Operate the transmitter by removing the pro-
tective paper from the batteries (display is active).
Set the clock, programs (PROG), constants
(CONST) and operating mode (AUTO / MANU).
The receiver is coded at the factory.
When the red Error LED on the receiver ashes ,
perform a TEST on the transmitter (see page 8).
If the wireless mode is not switched on, it is nece-
ssary to perform the coding, see p.5!


Product specificaties

Merk: Elektrobock
Categorie: Thermostaat
Model: BT52

Heb je hulp nodig?

Als je hulp nodig hebt met Elektrobock BT52 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Thermostaat Elektrobock

Handleiding Thermostaat

Nieuwste handleidingen voor Thermostaat