Electia SRA-88 Handleiding
Electia
Alarm ringer
SRA-88
Lees hieronder de 📖 handleiding in het Nederlandse voor Electia SRA-88 (12 pagina's) in de categorie Alarm ringer. Deze handleiding was nuttig voor 44 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/12
S
SR
RA
A-
-8
8
O
OW
WN
NE
ER
R’
’S
S
M
MA
AN
NU
UA
AL
L
A
Ar
rt
t.
.
3
36
6.
.2
28
86
69
9
1
G
GB
B
W
Wi
ir
re
el
le
es
ss
s
I
In
nd
do
oo
or
r
S
Si
ir
re
en
n
(
(S
SR
RA
A-
-8
8)
)
BACK VIEW
INSIDE VIEW
1. Battery Compartment
(with a lid secured with 4 screws)
2. Function Dip Switch
Contains 7 dip switches to enable the learning mode and to set the alarm period of siren.
3. Tampe r
4. Buzzer hole
5. 4 Mounting holes
Accessories included
Accessories included
Accessories included
Accessories includedAccessories included
In addition to the SRA-8 itself, the following accessories are also included in the package:
a. 4 x D-cell Alkaline Batteries to be placed in
b. 4 x 6mm dowels.
c. 4 x screws to be placed in four corners
D
Di
ip
p
S
Sw
wi
it
tc
ch
h
P
Po
os
si
it
ti
io
on
n
T
Ta
ab
bl
le
e
You can find dip switches marked 1-7 from left to right. The function of each dip switch is stated in the table below.
2
Dip 1
ON Learning Mode
OFF Normal Mode
Dip 3 Dip 4 Alarm Period
ON OFF 5 min
OFF ON 90 sec.
OFF OFF 3 min.
ON ON 1 sec.
Dip 6
ON Clear Memory
OFF Normal
*
*d
di
ip
p
s
sw
wi
it
t
c
ch
h
2
2,
,
5
5,
,
a
an
nd
d
7
7
i
is
s
p
pr
re
es
se
et
t.
.
SSRRAA--88 FFuunnccttiioonn OOvveerrvviieeww
S
Si
ir
re
en
n
M
Me
em
mo
or
ry
y
C
Cl
le
ea
ar
r
The siren can be reset and the memory contents cleared by removing the batteries, waiting for 1 minute, sliding dip
switch 6 to ON position and then re-inserting the batteries. The siren will produce a short confirmation tone. Dip switch
should then be slid to OFF position otherwise the siren code learning will be reset every time the siren has a power-up
sequence.
3
S
Si
ir
re
en
n
A
Au
ud
di
ib
bl
le
e
P
Pe
er
rf
fo
or
rm
ma
an
nc
ce
e
The siren produces a minimum of 104 dBA sound pressure at 1 meter on axis.
4 different siren duration is programmable via dip switch 3 and 4 (please refer to the table above):
1) 3 min.
2) 5 min.
3) 90 sec.
4) 1 second (test)
The fourth position (1 second) is used for testing during installation process.
The siren is silenced when either the siren duration expires or the control panel turns off the siren.
For Burglary alarm, SRA-8 gives continuous alarm sound.
For Fire and Water, SRA-8 gives an intermittent alarm sound for 460 ms ~ 1400 ms second and 460 ms of cyclical
sound during the programmed alarm duration.
T
Ta
am
mp
pe
er
r
A
Al
la
ar
rm
m
The siren is protected from its top lid removal. If the siren detects a tamper condition, it will activate the siren for the
programmed period. If the tamper condition persists, the siren will sound a series of five pips either every time the
system is armed or when the tamper is enabled, to indicate a fault. Tamper feature can be enabled/disabled from the
control unit by selecting the “Device +/- Program Siren“ menu then “ ”, and choosing between “Siren Tamp. ON” and
“Siren Tamp. OFF”. To confirm selection press OK.
C
Co
on
nf
fi
ir
rm
m
O
On
n,
,
C
Co
on
nf
fi
ir
rm
m
O
Of
ff
f
The siren can be programmed to produce additional confirmation beeps to tell you when the system is armed,
disarmed, and low in battery. The setting up procedure can be done from the control panel under “Device +/-“ menu
which leads to “Program Siren” menu which leads to selection of “Confirm On” or “Confirm Off”
Disable the Siren Confirmation by selecting “Confirmation Off” and press “OK”.
Enable the Siren Confirmation by selecting “Confirmation On” and press “OK”.
Mode Siren Audio
Arm 1 beep
Home 1 beep
Disarm 2 beeps
Low Battery Arm 5 beeps
Low Battery Home 5 beeps
Low Battery Disarm 5 beeps
At fault status it will perform the following:
Mode Siren Audio
Arm/ Home 5 beeps
Disarm 2 beeps
E
En
nt
tr
ry
y
S
So
ou
un
nd
d
O
On
n,
,
E
En
nt
tr
ry
y
S
So
ou
un
nd
d
O
Of
ff
f
The SRA-8 can be enabled or disable from sounding the Entry Delay warning beeps. The setting up procedure can be
done from the control panel under “Program Siren” menu.
Disable the Siren Entry Sound by selecting “Entry Snd Off” and press “OK”.
Enable the Siren Entry Sound by selecting “Entry Snd On” and press “OK”.
P
Pr
re
ev
vi
io
ou
us
s
A
Al
la
ar
rm
m
w
wa
ar
rn
ni
in
ng
g
If there has been an alarm when you were away, the siren will sound for 3 seconds when being disarmed.
WARNING: If the siren is activated for 3 seconds when you disarm your system, this means there could be an intruder
still in your premises.
Product specificaties
Merk: | Electia |
Categorie: | Alarm ringer |
Model: | SRA-88 |
Heb je hulp nodig?
Als je hulp nodig hebt met Electia SRA-88 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Alarm ringer Electia
23 April 2023
26 Maart 2023
21 Maart 2023
13 Maart 2023
27 Februari 2023
23 Januari 2023
15 Januari 2023
14 Januari 2023
10 Januari 2023
1 Januari 2022
Handleiding Alarm ringer
- Alarm ringer Honeywell
- Alarm ringer Abus
- Alarm ringer Amplicom
- Alarm ringer Ascot
- Alarm ringer Auriol
- Alarm ringer Beurer
- Alarm ringer Blaupunkt
- Alarm ringer Digi-tech
- Alarm ringer Envivo
- Alarm ringer Geemarc
- Alarm ringer GlobalTronics
- Alarm ringer Grothe
- Alarm ringer Hama
- Alarm ringer HQ
- Alarm ringer Hyundai
- Alarm ringer Konig
- Alarm ringer Lenco
- Alarm ringer Monacor
- Alarm ringer MT Logic
- Alarm ringer Nikkei
- Alarm ringer Renkforce
- Alarm ringer Sencor
- Alarm ringer Smartwares
- Alarm ringer Sonic Alert
- Alarm ringer Soundmaster
- Alarm ringer Techno Line
- Alarm ringer TFA
- Alarm ringer Velleman
- Alarm ringer X4 Life
- Alarm ringer Xavax
- Alarm ringer Jung
- Alarm ringer Olympia
- Alarm ringer Oregon Scientific
- Alarm ringer Cresta
- Alarm ringer Valcom
- Alarm ringer Delta Dore
- Alarm ringer La Crosse Technology
- Alarm ringer Dahua Technology
- Alarm ringer Homematic IP
- Alarm ringer Vimar
- Alarm ringer Pentatech
- Alarm ringer Gewiss
Nieuwste handleidingen voor Alarm ringer
18 November 2024
18 November 2024
18 November 2024
18 November 2024
18 November 2024
18 November 2024
18 November 2024
18 November 2024
18 November 2024
18 November 2024