UK Smoke Detector (SDA-9)
1. LED
When the battery voltage is low, the LED will flash every 30 sec.
While the smoke Detector is transmitting the signal, the LED will on.
While the batteries are inserted and the Smoke Detector is in warming and calibration process, the LED
will flash for 8~22 min.
2. Test Button
The Test Button is pressed in the following situations:
Learning – In the Smoke Detector.
To test the radio communication range.
To test if the Smoke Detector is functioning normally.
To silence the alarm
3. Battery compartment
4. Mounting Hole
5. Mounting Bracket
6. Hook
1
2
5
6
4
3
2007/6/22 - A
Battery
3 “ Alkaline batteries are used to supply power. The battery can last over 4 years. AA
When the Smoke Detector has low battery, a low battery signal will be transmitted along with regular
signal transmissions. If the battery voltage is low, the LED will flash accompanied with a Low-volume
beep once every 30 sec and inform the Control Panel regularly. Low Battery warning (<3.2 +/- 0.1V
typically starts 1 month before complete exhaustion.
Installation Procedures
1. Insert the 3 “ AA” batteries into the battery compartment taking care that the connection respects correct
polarity showing on the battery holder.
2. While the 4 batteries are inserted, the Smoke Detector will sound 2 short beeps, LED start flashing and
begin the 6-minute warming period.
3. During the 6-minute warming period, you can learn the Smoke Detector into the Panel.
To do the learning process
1. Put the Control Panel into Mode (or “ ” mode) to learn the ID code of the Smoke Add Device learning
Detector. (Please refer to operation manual of the panel.)
2. Press the Test Button on the Smoke Detector, the LED will be on for 2 sec and the buzzer will sound a
2-tone beep to indicate it’s functioning normally with successfully radio transmitting.
3. If the Control Panel successfully receives the signal, the panel will respond accordingly to indicate the
completion of the learning-in process. Please refer to the manual of the panel.
<Note>
When the 6-minute warming period is over, one short beep will sound to indicate that the Smoke
Detector is starting calibration process. The process will be repeated every 100 sec and notified by a
short beep respectively. The completion of calibration process will be notified by a 2-tone beep and the
LED will be turned off.
4. Normally it takes about 2 ~ 16 minutes to do the calibration. However, after 16 minutes, if the Smoke
Detector gives out continuous beeps instead, it indicates that the Smoke Detector is failed in the
calibration and its battery should be removed to silence the beeps. Then, start from step 1 to try again
after a pause of at least 30 seconds.
<Note>
During the calibration period, pressing the Test Button is prohibited. If you are not able to do the
learning process (Step 3) during the 6-minute warming period, you are requested to do the learning
process after the calibration period (Step 4).
5. After the completion of the warming and calibration process, put the Control Panel into “ Walk Test
mode. Then, decide upon a suitable location for the Smoke Detector’s installation and from there, press
the Test button to confirm this location is within signal range of the Control Panel.