Electia Gardsman CTC-1131 Handleiding

Electia Alarm ringer Gardsman CTC-1131

Lees hieronder de πŸ“– handleiding in het Nederlandse voor Electia Gardsman CTC-1131 (37 pagina's) in de categorie Alarm ringer. Deze handleiding was nuttig voor 36 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/37
24- -2009 APR
For ELECTIA
1
Table of Contents
Table of Contents
Table of Contents
Table of Contents Table of Contents
1. Application Overview ................................................................................................. 1
1.1. Identifying the parts .............................................................................................. 1
1.2. The Power Supply ................................................................................................. 2
1.3. Connecting the telephone line .............................................................................. 2
1.4. How to install the Control Panel ............................................................................ 2
1.5. Two-Level Passwords ............................................................................................ 2
1.6. Getting Started ..................................................................................................... 2
2. Conguring Your System .......................................................................................... 4
2.1. Entering Programming Mode ................................................................................ 4
2.2. Telephone Settings .............................................................................................. 4
2.3. General Settings ................................................................................................... 7
2.4. ADD/ Delete Device ............................................................................................ 14
2.5. Walk Test ........................................................................................................... 22
3. Operation ................................................................................................................. 23
3.1. Entering User Menu ............................................................................................ 23
3.2. Away (Alarm ON) Mode ...................................................................................... 23
3.3. Forced Arming ................................................................................................... 24
3.4. Disarm (Alarm o) Mode ................................................................................... 25
3.5. Home Arm Mode ................................................................................................ 25
3.6. Partial (By-pass) Arm Mode ................................................................................ 26
3.7. Alarm Activation ................................................................................................ 27
3.8. Stop the Alarm and Alarm Display ...................................................................... 28
3.9. Event Log ........................................................................................................... 29
3.10. Control PSS ....................................................................................................... 29
3.11. False Alarm Management .................................................................................. 30
3.12. Faulty Situations ............................................................................................... 30
3.13. Remote Access Via Regular Phone Lines ....................................................... 32
3.14. Dialing & Call Acknowledgment ........................................................................ 33
4. Appendix ................................................................................................................. 35
4.1. Reset Procedure ................................................................................................. 35
1
3
1. Application Overview
1.1. Identifying the parts
Backlit LCD Display
Microphone
Green LED
β€” AC Power Indicator; the Green LED
will light up when AC Power is on.
Yellow LED
β€” Fault Indicator; the Yellow LED will
light up when any fault situation is
detected and turn o when all fault
conditions are restored.
Numeric Keys



 Key
β€” In Programming mode, press this key
to move the cursor and scroll the
display upwards



 Key
β€” In Programming mode, press this key
to move the cursor and scroll the
display downwards.
Key
β€” In Programming mode, use this key
for deleting a digit, canceling the
selection, aborting the current screen
and returning to the previous screen
etc.
OK Key
β€” To conrm the keyed-in data or
conrm the selection.
# Key
β€” To enter the Programming menu
β€” For Telephone Number Setting; The
system will dial as it is entered.



 Key
β€” For Telephone Number Setting; it
represent 3-second delay when
dialing.
Buzzer
DC J ack
β€” For connecting the DC 9V power
adapter.
Phone Jack Marked Line
β€” This jack is for the connection to the
phone line from the wall.
Phone Jack Marked Phone
β€” This jack is for the connection to
the telephone unit.
Two Mounting Holes
Battery Switch
7
8
4