Eldat RTS39 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Eldat RTS39 (1 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 8 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/1
Junction Box Transmitter RTS39
EN
Model
RTS39E5002B01
Technical Details
Frequency: 868.3 MHz
Radiated power: 0.12 mW
Modulation: FSK
Coding: Easywave
Power supply: 230 V AC 50 Hz
Current consumption: 50 mA
Power consumption: max. 0.43 W
0.1 W stand by
Range: up to 150 m under
open îš¿eld conditions
Operating temperature: -20 °C to +60 °C
Dimensions: 48/48/25 mm
Weight: 32.0 g
Scope of Delivery
Junction box transmitter, jumper, operating
instructions
Intended Use
The Junction Box Transmitter may only be used
to operate Easywave radio receivers.
The manufacturer shall not be liable for any dam-
age caused by improper or non-intended use.
Safety Advice
Before using the device, carefully read
through the operating instructions
Caution! Electrical installation may only be
carried out by a qualiîš¿ed electrician!
In the electric power supply circuit to the ush-
mounted transmitter is required a suitable, eas-
ily accessible disconnecting device (e.g. auto-
matic circuit breaker).
Control unobserved never moving equipment or
electric heaters.
Note also the operating instructions of the radio
receiver.
Have faulty radio controls checked by the
manufacturer!
Do not make any unauthorized alterations or
modiîš¿cations to the transmitter!
Function
With the ush-mounted transmitter RTS39, the
functionality of existing switches or buttons can
be extended by a radio interface.
If a voltage is present at a switch or button, the
transmitter transmits the corresponding Easy-
wave code (A/B) to an Easywave receiver, which
then switches another device.
Caution: The connection of push-buttons is rec-
ommended only for modes with 2-button-opera-
tion!
Start-Up
1. Disconnect the electrical circuit and mount
the transmitter into a standard junction box.
Attention! Make sure there is no inter-fer-
ence with the wireless connection. Do not
mount the device in a distribution box, in met-
al casings, in direct proximity to large metal
objects, on the oor or close to it.
2. If you want to connect a switch, put the at-
tached jumper between the L and F terminals.
Factory, the transmitter is supplied to the
push-button operation (jumper not plugged).
3. Connect the power supply wires and switches
or buttons in a voltage-free state as shown in
the îš¿gures 1-3).
4. Put the lid on the junction box. Then turn o󰀨
the power supply again. Memorize the trans-
mission code in the receivers. Please read
the operating instructions supplied with the
receivers.
If the switch / button now pressed, the transmit-
ter transmits the appropriate control command to
the receiver.
SWITCH (jumper must be set between L+F)
S2 S1
N
N
230 V
L
L
S1F S2
L L
îš¿g. 1
The transmission starts on every change of state
of the switch and lasts approx. 0,5 seconds.
switch 1: input S1
close switch: --> code A1
open switch: --> code B1
switch 2: input S2
close switch: --> code A2
open switch: --> code B2
PUSH-BUTTON (no jumper between L+F)
S1
N
230 V
L
L
S2
L
N L S1F S2
îš¿g. 2
Transmission lasts as long as the button is
pressed but max. 36 seconds.
push-button 1 A1: input S1 --> code
push-button 2 B1: input S2 --> code
SHUTTER-CONTROL (no jumper between L+F)
S2
S1
N
230 V
L
ZU
AUF
L
N L S1F S2
îš¿g. 3
Transmission lasts as long as the button is
pressed but max. 36 seconds.
push-button A1 1: input S1 --> Code
push-button 2: input S2 --> Code B1
Programming transmitter
The RTS39 is programmed into the Easywave re-
ceiver by sending the desired transmission code
(A1 / A2 / B1 / B2).
To do this, press a connected push-button or
switch during the according step of the learning
procedure.
For more information about the learning process,
read the operating instructions of the respective
receiver.
Remote Learning
The RTS39 has a remote learning function. With
this function a built-in receiver can be brought into
learning mode or delete mode wirelessly.
If a receiver supports this feature, please refer to
its user manual.
Note that connected switching elements must be
open and a push-button must be connected nec-
essarily.
When the connected button is pressed, remote
learning telegrams are transmitted in the remote
learning function.
The jumper is used only for selection of the code
for the remote learning function, according to the
following scheme:
without jumper with jumper
S1 --> code A1
S2 --> code B1
S1 --> code A1
S2 --> code A2
For details on the remote learning function, refer
to the operating instructions of compatible recei-
vers.
Disposal
Waste electrical products and batteries not
be disposed of with household waste!
Dispose of the waste product via a col-
lection point for electronic scrap or via
your specialist dealer.
Put the packaging material into the
recycling bins for cardboard, paper and
plastics.
Warranty
Within the statutory warranty period we undertake
to rectify free of charge by repair or replacement
any product defects arising from material or pro-
duction faults.
Any unauthorized tampering with, or modiîš¿ca-
tions to, the product shall render this warranty
null and void.
Conformity
Hereby, ELDAT EaS GmbH declares that the ra-
dio equipment type RTS39 is in compliance with
Directive 2014/53/EU. The full text of the EU dec-
laration of conformity is available at the following
internet address: www.eldat.de
Service
If, despite correct handling, faults or malfunctions
occur or if the product was damaged, please con-
tact your retailer or the manufacturer:
ELDAT EaS GmbH
Schmiedestraße 2
15745 Wildau
Germany
Phone: + 49 (0) 33 75 / 90 37-0
Telefax: + 49 (0) 33 75 / 90 37-90
Internet: www.eldat.de
E-mail: info@eldat.de
learning
button
PTx
UM121658F_0522 DE/EN


Product specificaties

Merk: Eldat
Categorie: Niet gecategoriseerd
Model: RTS39

Heb je hulp nodig?

Als je hulp nodig hebt met Eldat RTS39 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Eldat

Eldat

Eldat RTS39 Handleiding

28 Februari 2024
Eldat

Eldat RTS13 Handleiding

28 Februari 2024

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd