Userā€™s Guide
UPS 8 ā€“ 15 kVA,
400 V 50/60 Hz output
(3-phase input/output)
Ā©2007 Eaton Corporation
All Rights Reserved
The contents of this manual are the copyright of the publisher and
may not be reproduced (even extracts)
unless permission granted.
Every care has been taken to ensure the accuracy of
the information contained in this manual, but no liability
can be accepted for any errors or omission. The right
to make design modiļ¬cations is reserved.
UPS 8 ā€“ 15 kVA, 400 V 50/60 Hz
Userā€™s Guide 1023625 revision C
Contents
1. Safety instructions ............................................................................................................................................................. 4
Audience .............................................................................................................................................................................. 4
CE marking ........................................................................................................................................................................... 4
User precautions ................................................................................................................................................................. 4
Environment ......................................................................................................................................................................... 5
Inquiries ................................................................................................................................................................................ 5
2. Mechanical installation .................................................................................................................................................... 6
Delivery check ..................................................................................................................................................................... 6
Unpacking and visual inspection ..................................................................................................................................... 6
3. Planning before installation ............................................................................................................................................. 8
4. Cabinet installation ............................................................................................................................................................ 9
Maintenance bypass switch ............................................................................................................................................. 9
Transformer option ............................................................................................................................................................. 11
External battery cabinet option ........................................................................................................................................ 12
Battery racks ....................................................................................................................................................................... 12
5. Electrical installation ........................................................................................................................................................ 13
Power cables and protective fuses ................................................................................................................................. 14
Wiring procedure ................................................................................................................................................................ 15
External Battery Cabinet (EBC) installation procedure ................................................................................................ 18
6. Software and connectivity ................................................................................................................................................ 20
Communication cables ....................................................................................................................................................... 20
Connection to the standard RS 232 port (X53)................................................................................................................ 20
LanSafe software ........................................................................................................................................................... 21
External control connections ............................................................................................................................................ 21
Emergency Power Off (EPO) ......................................................................................................................................... 23
Relay outputs ................................................................................................................................................................... 23
Programmable signal inputs ......................................................................................................................................... 23
XSlot communication (option) ........................................................................................................................................... 24
SNMP/Web Module (optional) ..................................................................................................................................... 24
AS400 Relay Module (optional) .................................................................................................................................... 25
Single Serial Port Module (optional) ........................................................................................................................... 25
Modus/Jbus Module (optional) .................................................................................................................................... 25
7. User operations ................................................................................................................................................................... 26
Display functions ................................................................................................................................................................. 26
User Settings ....................................................................................................................................................................... 27
Conļ¬guring user settings .............................................................................................................................................. 29
Changing language ........................................................................................................................................................ 29
Changing charging current ........................................................................................................................................... 29
Using relay outputs ........................................................................................................................................................ 29
Normal start-up ................................................................................................................................................................... 30
Battery start-up ................................................................................................................................................................... 30
Start-up after EPO ............................................................................................................................................................... 30
Shutdown ............................................................................................................................................................................. 31
8. Maintenance ....................................................................................................................................................................... 32
Regular service/intervals ................................................................................................................................................... 32
Batteries ........................................................................................................................................................................... 32
Cooling fan ....................................................................................................................................................................... 33
LED Indicators ..................................................................................................................................................................... 33
Maintenance bypass switch (MBS) operation .............................................................................................................. 33
Turn UPS from normal mode to mechanical bypass ................................................................................................ 34
Turn UPS from mechanical bypass to normal mode ................................................................................................ 35
9. Parallel systems ................................................................................................................................................................. 37
Overview ............................................................................................................................................................................... 37
Tie cabinets .......................................................................................................................................................................... 38
XSlot Hot Sync card: installing and wiring ..................................................................................................................... 42
Parallel operations .............................................................................................................................................................. 43
10. Recycling the used UPS or batteries ............................................................................................................................. 45
11. Dimensional drawings ..................................................................................................................................................... 47
12. Technical data ..................................................................................................................................................................... 48
Standards ............................................................................................................................................................................ 48
Environment ......................................................................................................................................................................... 48
Mechanical conļ¬guration ................................................................................................................................................. 48
Characteristics .................................................................................................................................................................... 48
AC input ................................................................................................................................................................................ 49
DC circuit .............................................................................................................................................................................. 49
AC output .............................................................................................................................................................................. 49
13. Warranty ............................................................................................................................................................................... 50


Product specificaties

Merk: Eaton
Categorie: UPS
Model: Powerware 9355-8-N-15-32x9Ah
Kleur van het product: Zwart
Gewicht: 160000 g
Breedte: 305 mm
Diepte: 702 mm
Hoogte: 817 mm
Geluidsniveau: 50 dB
Vormfactor: Tower
Certificering: IEC 62040-2, IEC 62040-3
Uitgangsvermogen: 7200 W
Frequentie: 45/65 Hz
Veiligheid: IEC 62040-1, IEC 60950-1
Power factor: 0.9
Seriƫle poort(en): 1
Efficientie: 98 procent
Type batterij: 9Ah
Aantal AC uitgangen: - AC-uitgang(en)
Output power capacity: 8 kVA
Ingang operation voltage (min): 220 V
Ingang operation voltage (max): 415 V
Uitgang operation voltage (min): 220 V
Uitgang operation voltage (max): 415 V
Aantal input fases: 3
Typische backup tijd op halve lading: - min
Typische backup tijd op volledige lading: - min
Input vermogensfactor: 0.99
Aantal output fases: 3
Input stroom THD: 4.5 procent