Dimplex WB7 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Dimplex WB7 (13 pagina's) in de categorie Ketel & boiler. Deze handleiding was nuttig voor 40 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/13
AUTO-FILL
WATER BOILERS
INSTRUCTION MANUAL
MODELS COVERED
WB3
WB7
WB15
WB5E
1
2
IMPORTANT HEALTH AND SAFETY INFORMATION
PLEASE READ BEFORE USING YOUR NEW WATER BOILER
Your new water boiler is designed to provide a constant source of near boiling
water for the preparation of hot drinks. THIS IS VERY HOT
All personnel must be provided with sufficient and appropriate training in the
safe use of this appliance.
An instruction sheet displayed next to the machine is often helpful in notifying
users that the appliance contains and dispense near-boiling water.
In line with Health & Safety requirements we recommend that a risk assessment
be carried out after the boiler has been installed.
It is advisable to display a sign informing customers that drinks made from this
boiler are very hot.
During normal use of the boiler, certain surfaces will become hot. (especially
near to the draw off tap). Care should be taken to avoid potential injury from
burns and scalding whilst operating the appliance.
Disclaimer. This appliance is designed to heat water. No other medium should
be used. Glen Dimplex UK Ltd will not be held responsible for any accidents or
injuries that occur from either misuse of the appliance or temperature of water
or the hot drinks served.
3
INTRODUCTION
Your new water boiler is designed to give years of trouble free service provided
that the instructions contained in this manual are followed carefully.
Your new boiler is energy efficient, simple to operate and easy to service.
It is recommended that the installation is carried out by a properly qualified fitter.
CHECK LIST
Before starting installation, check that you have the following parts:
1. Boiler Unit
2. Case
3. Mounting Template
4. Fitting Kit
5. Tap Kit (WB5E Only)
INSTALLATION
POSITIONING THE UNIT
The heater should be positioned in a convenient place on a wall that is capable
of supporting it safely. Use the mounting template and fitting kit provided.
Position the boiler so that the tap is about 400mm above a draining board.
Leave sufficient space around the unit to enable access for servicing, paying
particular attention to the position of the top centre fixing screw that holds the
cover in place.
Screw in the top two screws leaving about 6mm protruding and hang the
machine using the keyhole slots provided. Once the machine is positioned,
tighten the top screws and insert the bottom screw.
ELECTRICAL CONNECTION ALL MACHINES
Supply – 220/240V 50Hz – 3kW. The circuit should be protected by its own
13amp double pole connection unit with flex outlet to BS5733, alternatively the
circuit should have means of disconnection incorporated in fixed wiring, having
a contact separation of at least 3mm in all poles. Minimum cable size is 1.5mm2.
The use of an ELCB is recommended.
Electrical installation should conform to current I.E.E. wiring regulations.
When using fixed wiring, the bare section of earth wire must be sleeved to
within 8mm of the end.
Only a qualified electrician should carry out this work.