Dimplex RX9912 Handleiding


Lees hieronder de πŸ“– handleiding in het Nederlandse voor Dimplex RX9912 (3 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 40 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/3
ξ˜ƒ
ξ˜ƒ
Contactξ˜ƒ ξ˜ƒDetails
ξ˜ƒ
Pleaseξ˜ƒnoteξ˜ƒthat some contactξ˜ƒ ξ˜ƒofξ˜ƒtheξ˜ƒ ξ˜ƒdetails onξ˜ƒ ξ˜ƒ
thisξ˜ƒPDFξ˜ƒdocumentξ˜ƒmayξ˜ƒnotξ˜ƒbeξ˜ƒ ξ˜ƒcurrent.
ξ˜ƒ
Pleaseξ˜ƒuseξ˜ƒ ξ˜ƒ ξ˜ƒthe following detailsξ˜ƒifξ˜ƒyouξ˜ƒneedξ˜ƒtoξ˜ƒ
contactξ˜ƒus:ξ˜ƒ
ξ˜ƒ
Telephone:ξ˜ƒ0844 879ξ˜ƒ ξ˜ƒ3588ξ˜ƒ
Email:ξ˜ƒcustomer.services@gdcgroup.co.ukξ˜ƒ
ξ˜ƒ
ξ˜ƒ
The wideξ˜ƒcustomer alsoξ˜ƒsupportξ˜ƒsection websiteξ˜ƒofξ˜ƒourξ˜ƒ ξ˜ƒ ξ˜ƒfeaturesξ˜ƒ ξ˜ƒaξ˜ƒ
rangeξ˜ƒof ofξ˜ƒinformationξ˜ƒwhichξ˜ƒmayξ˜ƒbeξ˜ƒ ξ˜ƒuse availableξ˜ƒtoξ˜ƒyouξ˜ƒandξ˜ƒisξ˜ƒ ξ˜ƒ
24 aξ˜ƒhoursξ˜ƒ ξ˜ƒday.ξ˜ƒItξ˜ƒincludes:ξ˜ƒ
ξ˜ƒ
β€’ Operatingξ˜ƒ ξ˜ƒ ξ˜ƒ ξ˜ƒand installation instructions
β€’ Easyξ˜ƒ ξ˜ƒ ξ˜ƒ ξ˜ƒ ξ˜ƒ ξ˜ƒ ξ˜ƒ ξ˜ƒβ€˜How to use’ guides for storage heaters
β€’ Serviceξ˜ƒ ξ˜ƒ ξ˜ƒand repairs
β€’ Whereξ˜ƒtoξ˜ƒbuyξ˜ƒourξ˜ƒproductsξ˜ƒ
β€’ Literatureξ˜ƒ ξ˜ƒdownloads
β€’ Heatingξ˜ƒ ξ˜ƒ ξ˜ƒrequirement calculator
ξ˜ƒ
ξ˜ƒξ˜ƒξ˜ƒξ˜ƒξ˜ƒ ξ˜ƒβ€ξ˜ƒVisit www.dimplex.co.uk/supportξ˜ƒ
A division of GDC Group Ltd
Millbrook House Grange Drive Hedge End Southampton SO30 2DF
www.dimplex.co.uk
Re
g
istered No: 1313016 En
g
land
VAT GB 287 1315 50004
EEE Producer Registration Number –
WEE/GE0057TS
Paper from sustainable sources
Installation and
Operating Instructions
Mains Signalling Transmitter - Model No. RX9912
General Description
Installation
Single Zone Programming:
Multi Zone Programming:
Activating the Receivers:
The RX9912 can only be used in RPX, EVX and EVS heaters.
Each programmer may be used to provide single or multi zone programming for up to 20 slave
heaters, each fitted with a mains signalling receiver (Dimplex Part No. RX9913).
Two heating positions are offered: comfort and economy setback, with room temperatures set
using the controls on the heater.A choice of heating programmes are available for each day of
the week. There are 7 pre-set programmes, from P1 to P7 or a customised programme P=. In the
event of a power supply interruption or the cassette being removed from the heater, the memory
will retain current time and customised programme for 1 hour.The seven pre-set programmes will
remain stored indefinitely.
The RX9912 is rated at 230V.
1. Using a narrow bladed screwdriver, carefully release the cover from the slot adjacent to
the controls on the heater
2. Insert the programmer fully so that it clicks into position
3. Turn the control knob on the heater(s) to the PROG position
The heater containing the RX9912 is the transmitter or master heater, which
sends a message to the slave heaters, each containing the RX9913 receivers.
The transmitter heater determines the programme and heating levels for all the
heaters (Comfort, Setback and Frost Protection), but the actual comfort and
setback temperatures should still be set on each individual heater (see heater
instructions). The transmitter heater will switch between comfort and setback
according to the programme. On every slave heater, turn the control knob to
PROG.
In this mode all slave heaters will operate on the same master programme.
1. Insert the RX9912 into the master heater.
2. Press mode for 5 seconds. The house factory set code
appears.
3. Press mode to confirm the house code - the number 1 will
appear.
4. Press mode to confirm Zone 1.
5. During transmission the transmitter will flash EMET and the
number 1 alternatively.Activate all heaters containing receiver
following the instructions below (Β§ Activating the receivers).
It is possible to create up to 3 zones of heating using the RX9912 (One RX9912 per zone is
needed).
1. Insert the RX9912 into the master heater.
2. Follow the instructions for creating a single zone, but at step 4 use the
++++ key to select
option of zone 2 or 3.
3. Press mode to confirm OK when required zone is displayed.
4. The screen will now flash EMET and the appropriate zone number.
5. Activate all slave heaters containing receivers which you wish to be dedicated to either
zone 2 or 3 by following the instructions below.
1. Confirm the slave heater selector switch is positioned on PROG.
2. Press the small button (A) for 10 seconds (using a small screwdriver
blade or pen tip) until the neon indicator flashes.
3. Release and press again, light indicator will be ON.
4. Repeat process for each slave heater.
5. Return to master heater programmer and press OK
Display
1
2
3
4
5
6
7
03 : 58
+ -/Hgel OK MODE
Comfort Hours
Setback Hours
Override - Frost Protection
4. Choice of programme
for each day
1 segment per hour
1. Time
2. Day
3. Indicator
flashes
Transmitter (RX9912)
Receiver (RX9913)
Receiver (RX9913)
Power
Supply
Earth
Live
Neutral
A
EMET
+ -/Hgel OK MODE
T9909/010/A
421AA0793.A NR/BLA 49/99
- 1/2 -
Operating Instructions
Setting the time:
Choosing the programmes:
Frost Protection/Holiday Setting:
Overriding the master
programme:
Problem Solving
General Cleaning
After Sales Service
The RX9912 can be programmed either inserted directly into the heater or out of the heater. If
choosing the latter option, the cassette must be first left in the heater for 15 minutes to charge.
Remember that the charge only lasts for one hour when the cassette is removed from the heater.
00.00 flashes
1. Press the mode button once until hour flashes
2. Alter the hours with
+ or - sign and confirm OK
3. Alter the minutes with
+ or - sign and confirm OK
4. Alter the days with
+ or - sign and confirm OK
The black arrow marks the selected day (e.g. 1 = Monday, 2 = Tuesday etc).
Press mode twice (once for 2 seconds and once again briefly - P1 should flash) then with the
+
or - sign scroll through the preset programme choices P1 to P7 and P=. Select the programme
for day 1 (Monday) by pressing OK. Follow this sequence for each day of the week.
For reference the preset programmes are shown on the card attached to the programmer.
To choose the customised programme select P=, press mode and change the temperature
levels for every hour of the day by pressing + for comfort and - for setback. Then, after
completing the 24 hours, confirm the day with OK.
The programmer will revert to the original display screen (time + day + current programme
status) only after day 7 has received a programme.
The frost protection setting is continuous during the days it is set.
To set frost protection, press and hold the -/Hgel button until β€œHG : 01” appears. If used as a
group programmer all heaters will be set to frost protection. Press + or
- to set the number of
days required for frost protection (99 days maximum) e.g. β€œHG : 04” = 4 days. Press OK to
confirm.
After the set frost protection period has elapsed, the heater automatically returns to the original
programme.
To cancel frost protection before the end of the set period, press -/Hgel to return to the registered
programme.
When slave heaters are connected to a master, it is possible to manually override the master
programme by turning the control button on each slave heater to the required position (comfort,
setback, frost protection or off). To cancel the manual override and return to programmed
operation, turn back to the PROG position.
Display flashes and the timer cannot be adjusted: Exit the existing mode by pressing OK to
return to the beginning.
Display Blank: Cassette has been out of the heater for more than an hour: Reinsert cassette
into the heater for at least 15 minutes to charge (the charge lasts for one hour).
Fault Codes:
DEF 1: ram memory defect replace programmer
DEF 2: EPROM ram memory defect replace programmer
DEF 3: Bus CPL defect: electro-magnetic perturbation contact the installer
created by other electric equipment e.g.
computers etc.
DEF 4: Transmitter defect: 2 transmitters having the same check the zone numbers.
house code and zone numbers (use instructions on receiver cassette)
DEF 5: Frost protection defect: frost protection has been install transmitter in zone 1
set from zone 2 or 3 but there is no zone 1.
Press mode and OK at once for one minute, to delete fault codes on the screen.
BEFORE UNDERTAKING CLEANING WORK ON THE CONTROLLER OR APPLIANCE
IMMEDIATELY DISCONNECT THE ELECTRICITY SUPPLY EITHER BY SWITCH OFF AT THE
ADJACENT DOUBLE POLE SWITCH.
The outside of the appliance should be wiped over with a soft damp cloth and then dried. Do not
use detergents or abrasives.
Your Dimplex Control is guaranteed for one year from date of purchase. We undertake to
exchange or repair free of charge within this period, any part found to be defective.
Should you require after sales service, please get in touch with the supplier through whom you
purchased the appliance, or your nearest Service Agent.Please do not initially return a faulty
appliance or part of an appliance to us as this may result in transit damage and/or delay in
providing service. Let us know your difficulty quoting the model number and series of the
appliance. We will then take the appropriate action.
Glen Dimplex Manor House Avenue
Heating Ltd. Millbrook
Southampton
SO15 0AW
Customer Help Line (0870) 7270 101
Product Sales (0870) 7270 103
Head Office (0870) 0777 117
421AA0793.A NR/BLA 49/99
- 2/2 -


Product specificaties

Merk: Dimplex
Categorie: Niet gecategoriseerd
Model: RX9912

Heb je hulp nodig?

Als je hulp nodig hebt met Dimplex RX9912 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Dimplex

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd