Important - This manual must be left with the user after Installation!
EC-Eau Cylinder Range
Installation and User Instructions
Solar Direct, Solar Indirect and
Solar Heat Pump Cylinders
Up to 300L
Installation and User Instructions R01128-8 09/15
Page 2
Dimplex is a licensed member of the Benchmark Scheme which aims to improve
the standards of installation and commissioning of domestic heating and hot
water systems in the UK and to encourage regular servicing to optimise safety,
efficiency and performance.
Benchmark places responsibilities on both manufacturers and installers. The
purpose is to ensure that customers are provided with the correct equipment for
their needs, that it is installed, commissioned and serviced in accordance with
the manufacturer’s instructions by competent persons and that it meets the
requirements of the appropriate Building Regulations. The Benchmark Checklist
can be used to demonstrate compliance with Building Regulations and should be
provided to the customer for future reference.
Installers are required to carry out installation, commissioning and servicing work
in accordance with the Benchmark Code of Practice which is available from the
Heating and Hot Water Industry Council who manage and promote the Scheme.
Visit www.centralheating.co.uk for more information.
The HWA Charter requires that all members adhere to the following:
supply fit for purpose products clearly and honestly described
supply products that meet, or exceed appropriate standards and
building and water regulations
provide pre and post sales technical support
provide clear and concise warranty details to customers
For further information on the HWA Charter Membership, please refer to the
HWA website www.hotwater.org.uk
Installation and User Instructions R01128-8 09/15
Page 3
Overall View
0 Overall View
Figure 1: Overall view of Cylinder Installation process Solar Direct
02
03
09
01
07
04
08
06
05
Installation and User Instructions R01128-8 09/15
Page 4
Overall View
Figure 2: Overall view of Cylinder Installation process Solar Indirect
02
03
01
06
04
09
05
10
07
08
Installation and User Instructions R01128-8 09/15
Page 5
Overall View
Figure 3: Overall view of Cylinder Installation processSolar Heat Pump
02
03
11
01
06
04
09
05
10
07
08
12
Installation and User Instructions R01128-8 09/15
Page 6
Contents
1 Contents
0 OVERALL VIEW ...........................................................................................3
1 CONTENTS .................................................................................................6
2 INTRODUCTION ........................................................................................ 11
3 SCOPE OF DELIVERY ................................................................................. 12
4 PRE-INSTALLATION ADVICE ....................................................................... 15
4.1 R ISK ASSESSMENT ..................................................................................... 15
4.2 S ITING CONSIDERATIONS............................................................................. 15
4.3 C OLD WATER SUPPLY .................................................................................. 16
4.4 B D UILDING REGULATION G3 ISCHARGE REQUIREMENTS......................................... 17
4.4.1 Discharge pipe D2 ........................................................................ 18
4.4.2 Worked example ..........................................................................19
4.4.3 rmination of discharge pipe Te ........................................................ 20
4.5 L IMITATIONS............................................................................................ 21
5 INSTALLATION .......................................................................................... 21
5.1 C W I I C G OLD ATER NLET WITH NLET ONTROL ROUP ............................................... 21
5.1.1 Correctly site the cylinder .............................................................. 21
5.1.2 Install the inlet group .................................................................... 21
5.1.3 Expansion vessel .......................................................................... 21
5.1.4 Balanced cold water supply ............................................................ 22
5.1.5 Drain valve .................................................................................. 22
5.2 H W O OT ATER UTLET ..................................................................................22
5.2.1 Thermostatic mixing valve ............................................................. 22
5.2.2 Pipe insulation .............................................................................. 22
5.3 D ISCHARGE PIPES FROM SAFETY DEVICES .......................................................... 22
5.3.1 Discharge pipe D1 ........................................................................ 22
5.3.2 Discharge pipe D2 ........................................................................ 23
5.3.3 Tundish ....................................................................................... 23
5.4 I MMERSION HEATER....................................................................................24
5.5 S OLAR COIL CONNECTIONS ........................................................................... 25
5.6 A UXILIARY COIL CONNECTIONS ...................................................................... 25
5.7 T HERMOSTAT CONNECTION ........................................................................... 26
5.7.1 Auxiliary loop wiring schematic (indirect cylinder only) ...................... 27
5.7.2 Solar loop wiring schematic (direct and indirect cylinders) ................. 28
5.7.3 Solar sensor connection ................................................................. 29
5.8 C S R ONNECTION OF ECONDARY ETURN.............................................................. 34
6 COMMISSIONING ...................................................................................... 35
7 MAINTENANCE .......................................................................................... 36
8 SPARE PARTS ........................................................................................... 38
9 TECHNICAL DATA AND PRODUCT FICHE ...................................................... 39
Installation and User Instructions R01128-8 09/15
Page 7
Contents
9.1 C YLINDER HEAT EXCHANGER PRESSURE DROP ..................................................... 48
10 USER INSTRUCTIONS ................................................................................ 50
10.1 G ENERAL ............................................................................................. 50
10.2 O PERATION .......................................................................................... 51
10.2.1 Water temperature direct electric heating ........................................ 51
10.2.2 Water temperature auxiliary heating ............................................... 52
10.3 M AINTENANCE ....................................................................................... 52
10.4 T ROUBLESHOOTING................................................................................. 53
Installation and User Instructions R01128-8 09/15
Page 8
Important Information
Precaution: “This appliance can be used by children aged
from 8 years and above and persons with reduced physical
sensory or mental capabilities or lack of experience and
knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe way
and understanding the hazards involved. Children shall
not play with the appliance. Cleaning and user
maintenance shall not be made by children without
supervision.”
Note: Between the
inlet group and the
cold water inlet on the
cylinder isolating NO
device may be fitted,
as by doing so
important safety
devices could be
isolated!
It is important to
check the pre-charge
pressure of the
expansion vessel
membrane before
filling the cylinder.
This has been factory
set to 3 bar. The pre-
charge should be
greater than or equal
to 3 bar.
It is important that the
tundish is positioned
away from any
electrical components.
Note: Means for
electrical
disconnection must be
incorporated in the
fixed wiring in
accordance with the
wiring rules.
Before removing the
cover from the
immersion heater
isolate appliance using
isolating switch!
Danger of electrical
shock! Only use
suitable electrically
insulated equipment
Installation and User Instructions R01128-8 09/15
Page 9
Important Information
when working inside
immersion housing.
Note: The cylinder
must be filled with
water before switching
on the immersion
heater. Failure to do so
will damage the
element and void any
guarantee on the
product.
The maintenance of
this appliance must
be carried out by a
suitably qualified
person only. It is
recommended to
maintain the unit on
an annual basis.
Isolate all electrical
supplies from the
unit before
commencing work.
Danger of electrical
shock!
CLEANING
INSTRUCTIONS:
Clean outer
cladding of cylinder
with a soft cloth
dampened with
warm water only.
Do not use abrasive
or aggressive
cleaning materials,
such as alcohol or
petroleum based
solvents, as this
may damage the
surface of the
product.
Temperature setting: A
high level cutout is
fitted to the product for
each heat source. This
should never activate
under normal
operation. The
maximum possible
cylinder temperature
attainable by the heat
pump is 65°C as set on
the User Interface. The
back-up immersion
heater can produce up
to 72°C at its maximum
setting, i.e 5. For
Installation and User Instructions R01128-8 09/15
Page 10
Important Information
convenience the
immersion heater is
preset to produce
60°C.
If an electronic copy of
this manual should be
required, please contact
the manufacturer at the
address at the back of this
manual.
Note: This appliance is
intended to be
permanently
connected to the water
mains and not
connected by a hose-
set.
Dimplex cannot take
responsibility for ensuring
safe operation of the
appliance outside of the
scope of intended use.ly
Installation and User Instructions R01128-8 09/15
Page 11
Important Information
2 Introduction
Thank you for choosing a Dimplex
product. The EC-Eau solar cylinders are
specified with large, high surface area
heat exchangers, specifically sized to
match the requirements of Dimplex
solar systems. They boast 60mm of
low GWP insulation foam, together with
100% recyclable stainless steel inner
components and a sleek black, hard
wearing outer shell manufactured from
completely recycled materials. For
more detailed information on product
features, please see the Technical Data
section in this manual.
NOTE: This product has been designed
specifically for the purpose of
delivering heated, domestic and
sanitary hot water as part of a
pressurised water heating system. The
package is provided with fittings that
comply with Section G3 of Building
Regulations.
WARNING: Dimplex cannot take
responsibility for ensuring safe
operation of the appliance outside
of the scope of intended use.
Installation and User Instructions R01128-8 09/15
Page 12
Important Information
3 Scope of delivery
Please ensure you check the scope of
delivery below before signing any
delivery documentation. Claims for
missing or damaged parts after signing
for the delivery will not be accepted
.
Table 1: Scope of Delivery for CylindersSolar Direct
* These items are supplied factory fitted
Installation and User Instructions R01128-8 09/15
Page 13
Scope of Delivery
Table 2: Scope of Delivery for CylindersSolar Indirect
* These items are supplied factory fitted
Installation and User Instructions R01128-8 09/15
Page 14
Scope of Delivery
Table 3: Scope of Delivery for Cylinder Solar Heat Pump
* These items are supplied factory fitted
** Only part of the scope of delivery when not supplied as a Dimplex Heat Pump
package
Installation and User Instructions R01128-8 09/15
Page 16
Pre-Installation
- frost protection
The solar cylinder range designed to is
be floor standing, vertically mounted,
indoors and in a frost free
environment. The cylinder may be
located on any flat and level surface,
provided it is sufficiently robust to
support the weight of the cylinder
when full of water (please see technical
data) and suitably accessible for
replacement/maintenance without
specialist tools or lifting equipment as
this will void the warranty conditions.
The position and orientation of the
cylinder should be such that easy
access is provided for servicing the
controls. A minimum distance of
400mm in front of the immersion is
recommended, to allow the
replacement of the immersion heater
should the need arise. When installing
the cylinder all labels should be clearly
visible and ensure that no pipework
hinders any work to be carried out on
the various cylinder components.
Particular care must be taken when
placing the cylinder in a garage or
outbuilding. All exposed pipe work
must be correctly insulated to avoid
frost damage.
CLEANING INSTRUCTIONS:
Clean outer cladding of
cylinder with a soft cloth
dampened with warm water
only. Do not use abrasive or
aggressive cleaning
materials, such as alcohol or
petroleum based solvents, as
this may damage the surface
of the product.
4.3 Cold water supply
For satisfactory and safe performance
of the unvented cylinder the water
supply must meet the following
criteria:
Minimum dynamic
pressure
150 kPa
(1.5 bar)
Maximum inlet supply
pressure
1200 kPa
(12 bar)
Minimum flow rate
15 l/min
Max. chlorine content
250mg/L
Max. water hardness
200mg/L
The following instructions have to be
followed when installing the cold water
mains supply to the cylinder:
- The cold water supply to the cylinder
must come directly from the cold
water mains after the mains stop
valve to the property.
- The cold water inlet pipe work should
have at least an inside diameter of
19mm and should meet the
requirements of the water
regulations for the supply of
wholesome water.
Installation and User Instructions R01128-8 09/15
Page 17
Pre-Installation
Dimplex recommend an annual
maintenance inspection carried out is
on the domestic hot water cylinder. In
hard water areas this should include
inspection of the heat exchanger and
immersion heater, [above 120ppm or
120mg/l]. A local water treatment
company should be able to offer free
water quality testing. The heating
elements may require periodic de-
scaling. The installer should do this as
part of a maintenance agreement.
If required, precautions can be taken
to minimise effects of water hardness,
i.e. installation of water conditioner or
water softener. These devices should
be installed in hard water areas where
high water storage temperatures are
required, i.e. greater than 60°C
storage temperatures, particularly
when water hardness exceeds
200ppm. Should the water cylinder
require de-scaling, this must be
performed by a qualified technician.
4.4 Building regulation G3
Discharge
requirements
As part of the requirements of Building
Regulation G3 any discharge from an
unvented system should be conveyed
to where it is visible, but will not cause
danger to persons in or about the
building. The tundish and the discharge
pipes should be fitted in accordance
with the requirements of Building
Regulation approved document G3,
(England and Wales), Part P of
Northern Ireland and Standard 4.9 of
Scotland.
Installation and User Instructions R01128-8 09/15
Page 18
Pre-Installation
4.4.1 Discharge pipe D2
The discharge pipe (D2) from the
Tundish should:
- “have a vertical section of pipe at
least 300mm long below the
tundish before any elbows or
bends in the pipework and be
installed with a continuous fall of
at least 1 in 200 thereafter.”
The discharge pipe (D2) should be
made of:
- “metal; or other material that has
been demonstrated to be capable
of safely withstanding
temperatures of the water
discharged and is clearly and
permanently marked to identify
the product and performance
standard”
Dimplex strongly recommends the use
of metal pipework only and Dimplex
does not take responsibility for any
damage caused from discharges.
The discharge pipe D2 should be at
least one pipe size larger than the
nominal outlet size of the safety device
unless its total equivalent hydraulic
resistance exceeds that of a straight
pipe 9m long, i.e. for discharge pipes
between 9m and 18m the equivalent
resistance length should be at least two
sizes larger than the nominal outlet
size of the safety device; between 18
and 27m at least 3 sizes larger, and so
on; bends must be taken into account
in calculating the flow resistance. See
Figure 4 Table 4 and the worked ,
example.
Note: An alternative approach for
sizing discharge pipes would be to
follow Annex D, section D.2 of BS
6700:2006 + A1:2009).
Figure 4: Typical discharge pipe arrangement
Installation and User Instructions R01128-8 09/15
Page 19
Pre-Installation
Table 4 : Sizing of copper discharge pipe “D2” for common temperature relief valve outlet sizes
4.4.2 Worked example
This example is for a temperature
relief valve with a discharge pipe (D2)
(as fitted on 125 to 300L cylinders)
having 4 No. 22mm elbows and length
of 7m from the tundish to the point of
discharge.
From Table 4, the maximum resistance
allowed for a straight length of 22mm
copper discharge pipe
(D2) from a G½ temperature relief
valve is 9.0m. Subtract the resistance
for 4 No. 22mm elbows at 0.8m each
= 3.2m.
Therefore the maximum permitted
length
equates to 5.8m, which is less than the
actual length of 7m, therefore calculate
the next largest size.
Maximum resistance allowed for a
straight length of 28mm copper
discharge pipe (D2) from a
temperature relief valve is: 18m
Subtract the resistance for 4 No. 28mm
elbows at 1.0m each = 4m
Therefore the maximum permitted
length equates to 14m.
As the actual length is 7m, a 28mm
(D2) copper pipe will be satisfactory.