Dimplex DXUC2B Handleiding

Dimplex Heater DXUC2B

Lees hieronder de 📖 handleiding in het Nederlandse voor Dimplex DXUC2B (4 pagina's) in de categorie Heater. Deze handleiding was nuttig voor 22 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/4
08/51936/0 Issue 8
The product complies with the European Safety Standards EN60335:2-30 and the European Standard Electromagnetic Compatibility (EMC) EN55014:1,
EN55014:2, EN61000:3-2 and EN61000:3-3 which cover the essential requirements of EMC Directive 2014/30/EU and the LVD Directive 2014/35/EU.
As with all portable heang appliances: This product is suitable only for well insulated spaces or occasional use.
Installation and Operating Instructions
DXUC2B
Important Safety Advice
DO NOT use the heater in the immediate
surroundings of a bath, a shower or a swimming
pool.
DO NOT place the heater directly below a xed
socket outlet.
The socket-outlet must be accessible at all times
to enable the mains plug to be disconnected as
quickly as possible.
WARNING: In order to avoid a hazard due to
inadvertent resetting of the thermal cut-out,
this appliance must not be supplied through an
external switching device, such as a timer, or
connected to a circuit that is regularly switched
on and off by the utility.
WARNING: In order to avoid overheating, do not
cover the heater.
The heater carries the warning symbol
indicating that it must not be covered.
IMPORTANT: If the mains lead of this appliance is
damaged, it must be replaced by the manufacturer
or its service agent or a similarly qualied person
in order to avoid a hazard.
CAUTION: Some parts of this product can
become very hot and cause burns. Particular
attention has to be given where children and
vulnerable people are present.
WARNING: To avoid danger of suffocation please
remove all packaging materials particularly plastic
and EPS and keep these away from vulnerable
people,children and babies.
WARNING: To avoid the risk of accidental
strangulation from the supply cord all children and
vulnerable people must be supervised when in the
vicinity of the product whether it is working or not.
IMPORTANT: Avoid use of and extension cord
because the extension cord may overheat and
cause risk of re.
IMPORTANT: THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE
This appliance can be used by children aged from
8 years and above and persons with reduced
physical, sensory or mental capabilities or lack of
experience or knowledge if they have been given
supervision or instruction concerning the use of
the appliance in a safe way and understand the
hazards involved. Children shall not play with the
appliance. Cleaning and user maintenance shall
not be made by children without supervision.
Children of less than 3 years should be kept away
unless continuously supervised. Children aged
from 3 years and less than 8 years shall only
switch on/off the appliance provided that it has
been placed or installed in its intended normal
operating position and they have been given
supervision or instruction concerning the use of
the appliance in a safe way and understand the
hazards involved. Children aged from 3 years and
less than 8 years shall not plug in, regulate and
clean the appliance or perform user maintenance.
The heater should always be used on a at, stable
surface.
DO NOT use the heater on deep pile carpets or
the long hair type of rugs, or less than 750mm
(30”) away from any overhanging surface. Keep
combustible materials such as drapes and other
furnishings clear from the front, sides and rear of
the heater.
DO NOT use heater to dry your laundry.
The instruction leaet belongs to the appliance
and must be kept in a safe place. If changing
owners, the leaet must be surrendered to the
new owner.
DO NOT COVER or obstruct in any way the air
inlet slots in the top and bottom of the heater, or
the air outlet slots at the front of the heater.
DO NOT operate the heater with the mains lead
overhanging the front outlet grille.
Model s( )  Specication
DXUC2B 2.0kw Switch & Thermostat
DXUC2B Ceramic Fan Heater
Dimensions
(millimetres)
H W D
258 185 185
Fig. 1
6ZLWFK.QRE 7KHUPRVWDW.QRE
DO NOT CO VER
Electrical connection
This heater must be used on an ~ supply only and the
voltage marked on the heater must correspond to the
supply voltage. This heater is tted with a rewirable plug
incorporating a 13 amp fuse. In the event of replacing the
fuse in the plug supplied, a 13 amp fuse approved by ASTA
to BS 1362 must be used. If any other type of plug is used,
a 15 amp fuse must be tted in the plug, the adaptor, or at
the distribution board.
IMPORTANT : If the plug is not suitable for your socket,
the 13 amp plug should be removed. Before wiring the
appropriate plug, please note that the wires in this mains
lead are coloured in accordance with the following code :
BLUE : NEUTRAL
BROWN : LIVE
As the colours of the wires in the mains lead may not
correspond with the coloured markings in your plug, proceed
as follows :
Connect the wire to the terminal marked ‘ or coloured BROWN L
RED BLUE. Connect the wire to the terminal marked N or
coloured .BLACK Note : ‘L or ‘N’ wire must not be connected to
the EARTH terminal marked ‘E’ or or coloured or GREEN
GREEN AND YELLOW. If in doubt, consult your electrician.
Operation
Switch see Fig. 1
With the selector switch, the fan can be switched on or the
heat setting selected. The power indicating light illuminates
when the Switch is turned on.
Thermostat – see Fig. 1
In order to maintain a certain room temperature, set the
controller to max.’. Operate the appliance at full power
until the required room temperature is reached. Set back
the thermostatic controller until the appliance switches off
with an audible ‘click’. This temperature will be kept almost
constant by the thermostatic control switching on and off
automatically. Please note that the appliance can only be
switched on when the thermostat setting is higher than the
room temperature.
With the thermostat knob set to and the switch knob
set to the required heating output the appliance switches
on automatically when the temperature falls below +5°C -
+8°C.
Safety
Overheat Protection
For your safety, this appliance is tted with a thermal cut-out.
In the event that the product overheats, the cut-out switches
the heater off automatically.
To bring the heater back into operation, remove the cause of
the overheating, then unplug or turn off the electrical supply
to the heater for a few minutes. When the heater has cooled
sufciently, re-connect and switch on the heater.
Fuselink
A thermal fuse link is provided as an added safety feature.
If the fuse link operates and opens circuit it is the result of
abnormal overheating within the appliance and servicing
of the appliance by a competent service engineer will be
required in order to ensure the future safe operation of the
heater. Customer services should be contacted, who will
arrange the replacement of any faulty parts and the tting
of a new fuse link.
Cleaning
Switch off the appliance rst and disconnect the plug from
the socket. Clean the housing with a moist cloth, vacuum
cleaner or brush. Do not use any abrasive or caustic
cleaning agents. Do not use any flammable cleaning
agents e.g. petrol or spirit for cleaning the appliance.
Never immerse the appliance in water. Air inlet and outlet
area should be cleaned with a vacuum cleaner regularly. If
the appliance is not used for extended periods, it must be
protected against excessive dust and dirt.
Recycling
For electrical products sold within the
European Community. At the end of the
electrical products useful life it should not
be disposed of with household waste.
Please recycle where facilities exist. Check
with your Local Authority or retailer for
recycling advice in your country.
ModelIdentier(s): DXUC2B
Heat output
Nominal heat output Pnom 2.0 kW
Minimum heat output (indicative) Pmin 1.1 kW
Maximum continuous heat output Pmax,c 2.0 kW
Auxiliary electricity Consumption
At nominal heat output 0.0elmax kW
At minimum heat output elmin 0.0 kW
In standby mode elSB 0.0 kW
Type of heat output/ room temperature control
Mechanical thermostat room temperature control Yes
Contact details
GDC Group Limited
Millbrook House, Grange Drive, Hedge
End, Southampton.
SO30 2DF
Telephone: 0844 879 3588
Email: customer.services@gdcgroup.co.uk
Visit: www.gdcgroup.co.uk


Product specificaties

Merk: Dimplex
Categorie: Heater
Model: DXUC2B
Soort bediening: Draaiknop
Kleur van het product: Zwart
Aantal vermogenniveau's: 2
Gewicht: 1990 g
Breedte: 205 mm
Diepte: 205 mm
Hoogte: 274 mm
Snoerlengte: 1.5 m
Breedte verpakking: 215 mm
Diepte verpakking: 215 mm
Hoogte verpakking: 290 mm
Soort: Ventilator elektrisch verwarmingstoestel
Aantal snelheden: 2
Automatisch uitschakelen: Ja
Indicatielampje: Ja
Geschikt voor: Binnen
Instelbare thermostaat: Ja
Certificering: CE
AC-ingangsspanning: 230 - 240 V
Bevriezings beveiliging: Ja
Verwarmingsvermogen: 2000 W
Plaatsingsopties: Vloer
Verwarmingselement type: Keramisch