DataVideo TPC-700 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor DataVideo TPC-700 (149 pagina's) in de categorie Controller. Deze handleiding was nuttig voor 40 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/149
2
Table of Contents
TABLE OF CONTENTS ..................................................................................... 2
WARNINGS AND PRECAUTIONS 6....................................................................
WARRANTY ................................................................................................... 7
S WTANDARD ARRANTY ....................................................................................... 7
T Y WHREE EAR ARRANTY...................................................................................... 8
DISPOSAL 9......................................................................................................
CHAPTER 1 INTRODUCTI ON......................................................................... 10
1.1 F EATURES .................................................................................................. 10
CHAPTER 2 SYSTEM DIAGRAM .................................................................... 11
CHAPTER 3 CONNECTIONS .......................................................................... 12
3 F V .1 RONT IEW .............................................................................................. 12
3.2 R V EAR IEW ................................................................................................ 13
3.3 L V EFT IEW ................................................................................................. 14
3.4 R V IGHT IEW ............................................................................................... 15
CHAPTER 4 HOW TO TURN ON AND TURN OFF THE POWER OF THE TPC-
700/TPC-700P .............................................................................................. 16
CHAPTER 5 TPC-700 & TPC- . 700P’S SETTINGS OPTION ................................ 17
CHAPTER 6 BASIC SETUP ............................................................................. 24
6.1 C S A ONNECT BY TATIC IP DDRESS.................................................................... 24
6.2 C DHCP ONNECT BY ..................................................................................... 24
CHAPTER 7 NETWORK SETTINGS ................................................................. 25
7.1 C S A ONNECT BY TATIC IP DDRESS.................................................................... 25
7.2 C DHCP ONNECT BY ..................................................................................... 30
CHAPTER 8 THE 8 PRE-SAVED VIRTUAL SCENES FOR THE SE-3200 & TPC-
700/TPC-700P COMBINATION ..................................................................... 33
8.1 T I I HE NPUT NTERFACE ETTINGS FOR THE S SE-3200 & TPC-700/TPC-700P
C OMBINATION.................................................................................................. 34
3
8.2 T 8 P - HE RE SAVED VIRTUAL SCENES FOR THE AND SE-3200 TPC-700/TPC-700P
C OMBINATION.................................................................................................. 37
CHAPTER 9. HOW TO SET THE CHROMAKEY, SAVE A STILL TO MEMORY, P- -IN
P AND STILL FUNCTIONS .............................................................................. 40
CHAPTER 10 INTRODUCTION OF THE SE-3200 APP INTERFACE FOR THE TPC-
700/TPC-700P .............................................................................................. 41
10.1 V S IRTUAL CENES .......................................................................................42
10.1.1 H R P - V S OW TO ECALL THE RE SAVED IRTUAL CENES BY THE TPC-700/TPC-700P
.....................................................................................................................46
10.2 AUX ....................................................................................................... 47
10.2.1 H U F OW TO SE THE “AUX UNCTION ......................................................... 47
10.3 C P ROSS OINT............................................................................................ 49
10.3.1 H U C P F OW TO SE THE ROSS OINT UNCTION ................................................. 49
10.4 F S LEX OURCE............................................................................................ 52
10.4.1 H U F S F OW TO SE THE LEX OURCE UNCTION .................................................53
10.5 PIP......................................................................................................... 55
10.6 S ETUP ..................................................................................................... 57
CHAPTER 11. INTRODUCTION OF THE BUILT-IN VGB-2000 APP INTERFACE
FOR THE TPC-700/TPC-700P ........................................................................ 60
11.1 M I TPC- A -S & D AIN NTERFACE OF THE 700 PP INGLE UAL.................................. 61
11.2 O S PERATION TEPS FOR THE PP FOR VGB-2000 A TPC-700/TPC- 700P ............. 63
CHAPTER 12 INTERFACE INTRODUCTION OF THE TPC-700/TPC-700P BUILT-IN
DVK-400 APP ............................................................................................... 70
12.1 H OME ..................................................................................................... 70
12.2 I NPUT/OUTPUT ........................................................................................72
12.3 C HROMAKEY.............................................................................................73
12.4 L UMAKEY ................................................................................................. 74
12.5 W INDOW ................................................................................................76
12.6 USER MEMORY ..................................................................................... 77
12.7 C ONNECT................................................................................................. 78
12.8 S ETUP ..................................................................................................... 79
CHAPTER 13 INTERFACE INTRODUCTION OF THE TPC-700/TPC-700P BUILT-IN
ZR-1 APP ...................................................................................................... 85
4
13.1 C ONNECTIONS .......................................................................................... 85
13.2 -1 M I ZR AIN NTERFACE ............................................................................... 86
13.2.1 3 cams Interface-Home ................................................................. 88
13.2.2 2 cams Interface-Home ................................................................. 93
13.2.3 Connecon-for 3 cams & 2 cams Interfaces ................................. 95
13.2.4 Encoding-for 3 cams & 2 cams Interfaces ..................................... 97
13.2.5 Camera-for 3 cams & 2 cams Interfaces ..................................... 107
13.2.6 Switcher-for 3 cams & 2 cams Interfaces ...................................109
13.2.7 Audio-for 3 cams & 2 cams Interfaces ........................................ 116
CHAPTER 14 INTERFACE INTRODUCTION OF THE TPC-700/TPC-700P BUILT-IN
TVS-2000A APP .......................................................................................... 118
14.1 H OME ................................................................................................... 118
14.2 A DVANCE...............................................................................................126
14.3 S . TUDIO ................................................................................................ 128
CHAPTER 15 SOFTWARE UPDATE (APP MANAGE SW) . .............................. 130
CHAPTER 16. DIMENSIO NS ........................................................................ 132
CHAPTER 17. SPECIFICATIO NS ................................................................... 133
APPENDIX .................................................................................................. 134
SOFTWARE UPDATE PROCEDURE FOR TPC-700 & TPC-700P ...................... 134
1. INTRODUCTION ................................................................................ 134
2. PREPARATION .................................................................................. 134
2.1 YSTEM EQUIREMENTSS R ....................................................................134
2.2 S U P OFTWARE PDATE REPARATION................................................................ 135
2.3 S C D YSTEM ONNECTION IAGRAM .................................................................. 136
2.4 C S V HECKING THE OFTWARE ERSION .............................................................. 138
2.5 P S REPARING THE OFTWARE ......................................................................... 142
3. UPDATE ................................................................................................. 142
3.1 U S PDATING THE OFTWARE .......................................................................... 142
SERVICE AND SUPPORT ............................................................................. 156
5
Disclaimer of Product & Services
The information oered in this instrucon manual is intended as a guide only. At all mes,
Datavideo Technologies will try to give correct, complete and suitable informaon. However,
Datavideo Technologies cannot exclude that some informaon in this manual, from me to me,
may not be correct or may be incomplete. This manual may contain typing errors, omissions or
incorrect informaon. Datavideo Technologies always recommend that you double check the
informaon in this document for accuracy before making any purchase decision or using the
product. Datavideo Technologies is not responsible for any omissions or errors, or for any
subsequent loss or damage caused by using the informaon contained within this manual. Further
advice on the content of this manual or on the product can be obtained by contacng your local
Datavideo Oce or dealer.
6
FCC Compliance Statement
This device complies with part 15 of the FCC rules. Operaon is subject to the
following two condions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference
that may cause undesired operaon.
Warnings and Precauons
1. Read all of these warnings and save them for later reference.
2. Follow all warnings and instrucons marked on this unit.
3. Unplug this unit from the wall outlet before cleaning. Do not use liquid or
aerosol cleaners. Use a damp cloth for cleaning.
4. Do not use this unit in or near water.
5. Do not place this unit on an unstable cart, stand, or table. The unit may
fall, causing serious damage.
6. Slots and openings on the cabinet top, back, and boom are provided for
venlaon. To ensure safe and reliable operaon of this unit, and to
protect it from overheang, do not block or cover these openings. Do not
place this unit on a bed, sofa, rug, or similar surface, as the venlaon
openings on the boom of the cabinet will be blocked. This unit should
never be placed near or over a heat register or radiator. This unit should
not be placed in a built-in installaon unless proper venlaon is
provided.
7. This product should only be operated from the type of power source
indicated on the marking label of the AC adapter. If you are not sure of
the type of power available, consult your Datavideo dealer or your local
power company.
8. Do not allow anything to rest on the power cord. Do not locate this unit
where the power cord will be walked on, rolled over, or otherwise
stressed.
9. If an extension cord must be used with this unit, make sure that the total
of the ampere rangs on the products plugged into the extension cord do
not exceed the extension cord rang.
10. Make sure that the total amperes of all the units that are plugged into a
single wall outlet do not exceed 15 amperes.
7
11. Never push objects of any kind into this unit through the cabinet
venlaon slots, as they may touch dangerous voltage points or short out
parts that could result in risk of re or electric shock. Never spill liquid of
any kind onto or into this unit.
12. Except as specically explained elsewhere in this manual, do not aempt
to service this product yourself. Opening or removing covers may expose
you to dangerous voltage points or other risks, and will void your
warranty. Refer all service issues to qualied service personnel.
13. Unplug this product from the wall outlet and refer to qualied service
personnel under the following condions:
a. When the power cord is damaged or frayed;
b. When liquid has spilled into the unit;
c. When the product has been exposed to rain or water;
d. When the product does not operate normally under normal
operang condions. Adjust only those controls that are covered by
the operang instrucons in this manual; improper adjustment of
other controls may result in damage to the unit and may oen
require extensive work by a qualied technician to restore the unit to
normal operaon;
e. When the product has been dropped or the cabinet has been
damaged;
f. When the product exhibits a disnct change in performance,
indicang a need for service.
Warranty
Standard Warranty
Datavideo equipment are guaranteed against any manufacturing defects
for one year from the date of purchase.
The original purchase invoice or other documentary evidence should be
supplied at the me of any request for repair under warranty.
The product warranty period beings on the purchase date. If the purchase
date is unknown, the product warranty period begins on the thireth day
aer shipment from a Datavideo oce.
All non-Datavideo manufactured products (product without Datavideo
logo) have only one year warranty from the date of purchase.
8
Damage caused by accident, misuse, unauthorized repairs, sand, grit or
water is not covered under warranty.
Viruses and malware infecons on the computer systems are not covered
under warranty.
Any errors that are caused by unauthorized third-party soware
installaons, which are not required by our computer systems, are not
covered under warranty.
All mail or transportaon costs including insurance are at the expense of
the owner.
All other claims of any nature are not covered.
All accessories including headphones, cables, and baeries are not
covered under warranty.
Warranty only valid in the country or region of purchase.
Your statutory rights are not aected.
Three Year Warranty
All Datavideo products purchased aer July 1st, 2017 are
qualied for a free two years extension to the standard
warranty, providing the product is registered with Datavideo
within 30 days of purchase.
Certain parts with limited lifeme expectancy such as LCD panels, DVD
drives, Hard Drive, Solid State Drive, SD Card, USB Thumb Drive, Lighng,
Camera module, PCIe Card are covered for 1 year.
The three-year warranty must be registered on Datavideo's ocial
website or with your local Datavideo oce or one of its authorized
distributors within 30 days of purchase.
9
Disposal
For EU Customers only - WEEE Marking
This symbol on the product or on its packaging indicates
that this product must not be disposed of with your other
household waste. Instead, it is your responsibility to dispose
of your waste equipment by handing it over to a designated
collecon point for the recycling of waste electrical and
electronic equipment. The separate collecon and recycling of your waste
equipment at the me of disposal will help to conserve natural resources and
ensure that it is recycled in a manner that protects human health and the
environment. For more informaon about where you can drop o your waste
equipment for recycling, please contact your local city oce, your household
waste disposal service or the shop where you purchased the product.
10
Chapter 1 Introducon
Datavide TPC-700/TPC-700P is the best assistant for all 3200 o
switchers, and VGB-2000 presentaon system. The SE-3200 and VGB-
2000 Apps that are installed on the TPC-700/TPC- contain presets 700P
of common operaon funcons. Just tap on the screen to easily select
dierent presets. Each buon can be customized to your liking. Mul-
camera Virtual Studio switching, AUX output, Crosspoint, Flex Source,
and PIP assignment can be done by the TPC-700/TPC-700P. Easy to
transport to your live producon show on the go. Quick connecon.
Simple installaon.
1.1 Features
The Touch Panel supports 800 x 480 resoluon.
Supports Wall mount installaon and complies to standard VESA
dimensions 10cm x 10cm
7” Capacive Touch Panel
Supports PoE Power Supply(For TPC- Only) 700P
11
Chapter 2 System Diagram
12
Chapter 3 Connections
This chapter will show you the connecons of the TPC-700/TPC-700P
Touch Panel Controller. For the details of the TPC- 0/TPC-700P70 ,
please refer to following chapters.
3 Front View .1
Interface
Descripon
Touch Panel
This is the touch panel of the TPC-700/TPC-700P touch
panel controller.
13
3.2 Rear View
Interface
Descripon
Rear Panel
This is the rear panel of the TPC-700/TPC-
700P Touch Panel Controller. It provides
standard VESA 10cm x 10cm mounng holes.
14
3.3 Le View
Interface
Descripon
RJ-45 Ethernet Interface for RS-232 Control only ( )
This RJ-45 interface is for RS-232 Control only. If users
use the TPC-700/TPC-700P to control the SE-3200, it is
no need for this interface to connect due to that the
TPC-700/TPC-700P adopts the DVIP protocol to
control the SE- 0. 320
USB Interface
Users can use this USB interface for updang the
soware and for installing the remote control
soware of other models.
15
3.4 Right View
Interface
Description
12VDC IN interface
Please connect a 12V DC power cable to this interface
for powering the TPC-700/TPC-700P .
RJ-45 Ethernet Interface For DVIP Control & PoE
Only
Please connect one end of an RJ-45 Ethernet cable to
this interface and then please connect the other end
of this cable to the device that must be controlled by
the DVIP protocol. This interface can be used for
supporting the PoE (802.3af) Power Supply.
Note: The PoE function can be used only for the TPC-
700P.
ON/OFF Power Switch
Users can turn on or turn off the power of the TPC-
700/TPC- by this switch. 700P
16
Chapter 4 How to turn on and turn off the
power of the TPC-700/TPC-700P
How to Turn On the Power
Please use the ON/OFF power switch which is located on the right side
of the TPC-700/TPC-700P to turn on the power of the TPC-700/TPC-
700P.
How to Turn Off the Power
Use the ON/OFF switch: Please use the ON/OFF power switch
which is located on the right side of the TPC-700/TPC-700P to
turn off the power of the TPC-700/TPC-700P
Use the APP: There is a Power-Off button which is located at the
bottom side of the TPC-700 APP. Press this button can turn off
the power of the TPC-700/TPC-700P.
17
Chapter 5 TPC-700 & TPC- 700P’s Settings Option
After you turn on the TPC-700 or the TPC-700P, it will enter the main
screen and there is a “Settings” icon which is located at the top-right
side of the main screen.
After pressin -g the icon, you can enter the “TPC 700 Setup” interface, the
purpose for this “TPC 700 Setup” page is for you to set various network -
parameters of the TPC-700/TPC-700P. Moreover, it also allows you to install
and uninstall various apps for different product models which are installed in
the TPC-700 or the TPC-700P. In the “TPC 700 Setup” interface- , there are
several parameters including “Language”, TPC 700 Network”, App Manage”, -
Autorun last App” and “FW Version”. The main interface of the TPC-700
Setup” is shown in the following diagram, please refer to following paragraphs
for details.
18
Language: Please press this button to select your desired language from
three languages including traditional Chinese, English and simplified
Chinese. After that, please press the “Save” button for saving the
settings.
TPC-700 Network: Please press this key to set various network related
parameters including DHCP ON/OFF switch, IP address, Network Mask,
Gateway and Primary DNS. The main interface of the “TPC ork” -700 Netw
option is shown in the following diagram.
19
DHCP ON/OFF Toggle Switch: If you connect the TPC-700/TPC-700P and
your DVK-400 to the same router and then this ON/OFF toggle switch is
set to “ON”, the TPC-700/TPC-700P will obtain the IP address
automatically from the router. If this ON/OFF toggle switch Is set to
“OFF” and then you need to set the static IP address and related network
parameters manually by yourself.
IP Address: If the DHCP ON/OFF toggle switch is set to “OFF” and then
you need to set the static IP address manually from this section. After
the static IP address is entered, please tap the “OK” button for applying
it.
Note: Please pay attention that the static IP address of the TPC-700/TPC-
700P must be within the same LAN according to the default static IP
address of the connected Datavideo product.
21
Primary DNS: Please press this button for setting the primary DNS
address, the default primary DNS address is 8.8.8.8.
MAC Address: This section will show the MAC Address of the TPC-
700/TPC-700P.
APP Manage: Press this button allows you to install related Apps
for the Datavideo products in the TPC-700/TPC-700P. The main
interface of the “App Manage” option is shown in the following
diagram.
How to uninstall the App
1. Please press the “Uninstall” button beside the product App that is
needed to be uninstalled. After that, the App will be uninstalled
automatically.
2. A reminding dialogue box will be shown. Please press the “OK”
button and then the app will be uninstalled.
How to install App
1. Please download App file for your product model from Datavideo
official website https://www.datavideo.com. The file name is “SE-3200
firmware for TPC-700P_V2.2.10.zip” (Take SE-3200 as an example).
2. Please unzip the downloaded zip file. After that, please unzip the
“product model name_vx.x.x.zip” and then you will see a “datavideo”
file folder with “tpc700.apkg” file in it. Please copy the whole
“datavideo” file folder into the root directory of your USB flash drive.
3. Please insert the USB flash drive into the USB interface which is
located at the left side of the TPC-700/TPC-700P controller.
4. Please press the “Install” button which is located at the top-right
side of the “App Manage” interface and then the App will be installed
automatically.
Autorun last App ON/OFF toggle switch: If this toggle switch is
“ON”, for the next time when the TPC-700 or the TPC-700P is
turned on, it will run the app which is operated for the last time
automatically.
23
FW Version: This section will show current version number of the
“App Manage” software which is installed in the TPC-700 or the
TPC-700P.
LCD Backlight: This slider allows you to adjust the LCD Backlight
brightness with the range of 20%-100%.
24
Chapter 6 Basic Setup
Before using the TPC-700/TPC-700P to control other devices, please
make sure that the basic setup of the TPC-700/TPC-700P is done. This
chapter will make the SE-3200 HD 12-Channel Digital Video Switcher as
an example for explaining how to set the basic setup between the TPC-
700/TPC-700P and the SE-3200. Please set the basic setup of the TPC-
700/TPC-700P according to following steps.
6 Connect by Static IP Address .1
1. Please use an RJ-45 Ethernet cable to connect from the Ethernet
interface on the rear panel of the SE-3200 to the DVIP RJ-45 Ethernet
interface on the right side of the TPC-700/TPC-700P .
6 Connect by DHCP .2
1. Please use an -45 Ethernet cable to connect from the Ethernet RJ
interface on the rear panel of the SE-3200 main unit to the RJ-45
Ethernet interface on your router.
2. Please use an RJ-45 Ethernet cable to connect from the DVIP RJ-45
Ethernet interface on the right side of the TPC-700/TPC- to the RJ-700P
45 Ethernet interface of the same router.
25
Chapter 7 Network Settings
For the network settings of the TPC-700/TPC- , please see following 700P
chapters.
7 Connect by Static IP Address .1
If the -700/TPC-700P and the SE-3200 are brand new devices. TPC
The brand new default value of the SE-3200 switcher is the static IP mode and
the static IP address is For the brand new TPC-700/TPC-192.168.100.101.
700P Touch Panel Controller, its default network mode is the static IP address
mode and the IP address is If users want to connect the 192.168.100.102.
TPC-700/TPC-700P to the SE-3200 by the static IP mode, please connect the
TPC-700/TPC-700P and the SE-3200 with an RJ-45 Ethernet cable.
If the IP address of the -700/TPC-700P or the SE-3200 is not the TPC
default value
If the IP address of the SE-3200 is not the default value, please refer to
“Network and Software Setup for Switcher” in the SE-3200 user manual to
know the IP address, subnet mask and default gateway of the SE-3200. And
then please set the IP address of the TPC-700/TPC-700P to be within the same
IP range for further operation.
31
3. -Please turn “ON” the “DHCP ON/OFF” toggle switch. After that, the TPC 700
or the TPC-700P will obtain the network related parameters including IP
address, Network Mask, Gateway AND Primary DNS from the connected
router automatically. After all parameters are obtained, please press the
“Apply” button for applying the settings.
4. After going back to the main interface of the TPC-700/TPC-700P, please tap
the SE-3200 App.
35
SDI IN 2
( )CH2
Please set the Camera 2 in the middle to shoot the close-
up for the talent and guests who are sitting in front of the
green mat.
SDI IN 3
( )CH3
The Camera 3 must be set on the right side to shoot the
close-up for the talent who is sitting in front of the green
mat.
37
CH9
Please connect a PC to the HDMI IN9 interface of the SE-
3200(CH9)(for playing slides or videos)
8 The 8 Pre-saved virtual scenes for the SE-3200 and TPC-.2
700/TPC-700P Combination
Combination of
Screen Elements
Final Composite Screen
Wide Angle with
Background
CH1 Chromakey+CH5
Virtual Scene
Full-Body Chromakey with Virtual Scene
Close-up with
Background CH2
Chromakey+CH6
Virtual Scene
Half-Body Chromakey with Virtual Scene
39
Talent B+ PC Source
CH4
Chromakey+CH9
Background
Talent B Half-Body +Content
Talent A Close-up
with Background+ PC
Source) CH3
Chromakey +CH7
Background+CH9
PIP
Talent A Half-Body Chromakey with Virtual
Scene+ Content
Talent B Close-up
with Background +PC
Source CH4
Chromakey+CH8
Background+CH9
PIP
Talent B Half-Body Chromakey with Virtual
Scene+ Content
40
Chapter 9. How to Set the Chromakey, Save a Still to
Memory, P- -P and Still Functions In
It is necessary to use the Chromakey and Still related functions of the
SE-3200 for controlling the SE-3200 and for recalling the pre-saved
virtual scenes directly by the TPC-700/TPC-700P. For the setting details
and the operating steps, please refer to the 4.2 Keyer 4.3 Chroma 4.4 , ,
P- -In P and the related paragraphs of the from the SE-Still 4.9 Files
3200 user manual.
41
Chapter Introduction of t -3200 App Interface 10 he SE
for the TPC-700/TPC-700P
The built-in SE-3200 control App for the Datavideo TPC-700/TPC-700P
includes “Virtual Studio”, “AUX”, “Cross Point”, “Flex Source”, “PIP”
and “Setup” options for users to control the SE-3200 remotely by the
TPC-700/TPC-700P and an RJ-45 Ethernet cable. The main interface of
the built-in SE-3200 control App for the TPC-700/TPC-700P is shown as
following diagram.


Product specificaties

Merk: DataVideo
Categorie: Controller
Model: TPC-700

Heb je hulp nodig?

Als je hulp nodig hebt met DataVideo TPC-700 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Controller DataVideo

Handleiding Controller

Nieuwste handleidingen voor Controller