Danfoss SonoSelect 10 Handleiding

Danfoss Meetapparatuur SonoSelect 10

Lees hieronder de 📖 handleiding in het Nederlandse voor Danfoss SonoSelect 10 (38 pagina's) in de categorie Meetapparatuur. Deze handleiding was nuttig voor 36 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/38
2 01.02.00 © Danfoss| Energy Meters| 2018.02|
1 Basic information 4 ....................................................................................................
1.1 The physical layer ............................................................................................. 4
1.2 Wake up process and baud rate changes (IR) ....................................................... 4
1.3 Baud rate changes 4 ............................................................................................
1.3.1 Wait time before reply after correct message reception .................................... 5
1.4 Data Link layer (DLL) ......................................................................................... 5
1.4.1 C field (Control field, Function fiel Field size 1 byte d) – ................................... 5
1.4.2 A Field (Address Field) 1 byte 6 –....................................................................
1.4.3 L Field 2 fields with a size of 1 byte –............................................................ 7
1.4.4 CS field 1 byte –......................................................................................... 7
1.5 Combined Transportation and application layer ..................................................... 8
1.5 CI Field (Control information field) .1 ................................................................ 8
1.5.2 Long header ............................................................................................... 9
1.5.3 Status byte and error handling ................................................................... 10
1.5.4 DIF & VIF configuration of data records ........................................................ 11
1.6 The standard read out ..................................................................................... 13
2 Communication process ......................................................................................... 16
2.1 M-Bus EN 13757 data frames ........................................................................... 16
2.2 Pulse readout . ................................................................................................ 17
2.3 Application reset ............................................................................................. 17
2.4 Send/Confirm procedures available using the Danfoss Meter ................................. 21
2.4.1 SND_NKE ................................................................................................. 21
2.4.2 SND_UD .................................................................................................. 22
2.4.3 REQ_UD2 ................................................................................................. 34
2.4.4 RSP_UD ................................................................................................... 35
Annex A ..................................................................................................................... 36
3 01.02.00 © Danfoss| Energy Meters| 2018.02|
Identify the needed telegrams from the EN13757 standard and determine how to implement
the SonoSelect 10 and SonoSafe 10 communication protocol into an M-Bus telegram. This
document contains the description the M-Bus protocol implemented for SonoSelect 10 and
SonoSafe 10. The M-Bus protocol will follow the EN13757 standard.
According to the software architecture of the SonoSelect 10 and SonoSafe 10 the
communication shall be split into three layers.
Figure 1 - OSI model and architecture of HM
The M-Bus protocol for the IR and Wired communication will be identical and therefore these
two components will share the same data-link and application layer. The M-Bus will only
support physical, data-link and combined transportation and application layer. The other layers
stated in EN13757-3 are optional and will not be part the wired M-Bus implementation of the
SonoSelect 10 and SonoSafe 10. According to the EN13757-1 standard the transportation layer
must be handled in an Application Layer.


Product specificaties

Merk: Danfoss
Categorie: Meetapparatuur
Model: SonoSelect 10

Heb je hulp nodig?

Als je hulp nodig hebt met Danfoss SonoSelect 10 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Meetapparatuur Danfoss

Handleiding Meetapparatuur

Nieuwste handleidingen voor Meetapparatuur