CyberPower PowerTrip CPS480TG2U Handleiding

CyberPower Accu PowerTrip CPS480TG2U

Lees hieronder de 📖 handleiding in het Nederlandse voor CyberPower PowerTrip CPS480TG2U (4 pagina's) in de categorie Accu. Deze handleiding was nuttig voor 28 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/4
1. 120 volt AC outlet
2. USB charging ports (2.4 AMPS)
3. LED indicator light [Power LED(Green), Input / Output Fault (Red)]
4. ON/OFF Switch
5. DC Input positive terminal
6. DC Input negative terminal
7. Cooling Fan
8. Fuse
Follow these steps to connect the PowerTrip 480 to the vehicle cigarette
lighter socket (for loads under 150 watts).
1. Place the inverter on a flat surface on your vehicle floor.
2. Make sure the power switch on the panel is off.
3. Take the power cord equipped with the cigar plug and place the ring
terminals over the two cabling terminals on the back of the inverter.
4. Place the inverter cigar plug in the vehicle cigarette lighter socket.
5. Turn on the power switch. The green light indicates that the inverter is
operating normally and that AC power is available at the outlet.
6. Verify that the connected device(s) draws less than 150 watts and plug
into the AC outlet.
7. Always turn the inverter off when not in use.
Follow these steps to connect the power inverter directly to the vehicle's
battery (for loads over 150 watts).
1. Place the inverter on a flat surface.
2. Make sure the power switch on the panel is off.
3. Take the power cord equipped with battery clamps on one end and
place the ring terminals over the two cabling terminals on the back of
the inverter.
4. Fasten the positive (red) clamp to the positive battery post, and then
fasten the negative (black) clamp to the negative battery post.
5. Turn on the power switch. The green light indicates that the inverter is
operating normally and that AC power is available at the outlet.
6. Take device power cord plug into the inverter AC outlet.
7. Always turn the inverter off when not in use.
Make sure you connect cable red to red and black to black, and make
sure you screw the nuts on tightly.
Use the cigar plug cable only when the vehicle’s engine is running.
Use the cigar plug cable with the engine off will cause excessive
battery drain.
CAUTION :
1. Connect the RED cable to the
POSITIVE terminal of the battery.
2. Connect the BLACK cable to the
NEGATIVE terminal of the battery.
A reverse polarity connection (positive to negative) will blow a fuse in
the inverter and may permanently damage the unit. Damage caused
by a reverse polarity connection is not covered by your warranty.
Batteries contain corrosive materials and present an electrical shock
hazard. To prevent irritation and burns, wear protective eyewear and
clothing when you install the inverter or work with the batteries.Take
special care to ensure that metal tools and personal metal objects like
rings and bracelets do not contact the battery terminals.
CAUTION
WARNING
CAUTION
Battery
Red
Black
(+)
(-)
Front View
Back View
1
2
3
5
6
7
8
4
1 1
Introduction
Product Overview
Product Features
Operation: Connecting the power cord for loads under
150 watts
Operating and Storage Tips
Operation: Connecting the power cord for loads over
150 watts
Package Contents
AC Mobile Power Inverter
CPS480TG2U/B
480 User Guide
TM
This guide contains important information regarding the safety, operation,
maintenance, and storage of this product. Failure to read this guide and
follow the directions could result in injury and/or property damage.
Before installing and using the CyberPower power inverter, please read
the manual. Misusing or incorrectly connecting the Inverter may damage
the equipment or create hazardous conditions for users. Read the
following safety instructions and pay special attention to all CAUTION
and WARNING statements in the manual.
• Do not operate the inverter near flammable materials, fumes, or gases.
Always use the inverter where there is adequate ventilation. Do not
obstruct the ventilation slots.
• Never immerse the unit in water or other liquids.
• Proper cooling is essential when operating the inverter. Refrain from
placing the inverter near the vehicle's heat vent or in direct sunlight.
Always turn the inverter off when not in use by removing it from the DC
accessory port.
• Check the warning labels on battery chargers or adapters before
connecting them to the inverter. Do not connect battery chargers or
adapters that have warnings about using with inverters.
Thank you for choosing the CyberPower power Inverter. To enjoy all the
features and benefits of Inverter, please read and follow all instructions.
The power inverter is a portable source of 120 volt AC power. The AC
power converts DC battery power from your vehicle into standard 120 volt
AC power, allowing you to power most notebook computers, cell phone
chargers, camcorders, and other electronic products drawing AC power.
This product package includes:
AC Power Inverter
• Cigar Plug Cable
• Battery Clamp Cable
• User Guide
CAUTION:
1. Connect the RED cable to the
POSITIVE terminal of the inverter.
2. Connect the BLACK cable to the
NEGATIVE terminal of the inverter.
The inverter should only be operated under the following conditions:
• Dry - Do not allow water or other liquids to come into contact with the inverter.
• Moderate Temperature - Ambient air temperature should be between
32 °F - 104 °F (0 °C - 40 °C). Keep the inverter out of direct sunlight.
• Free Air Flow - Keep the inverter's ventilation slots unobstructed to
ensure air flow to the unit. Do not place any items on or over the inverter
during operation. The unit will shut down if it overheats.
• Proper storage temperature range is 32 °F - 122 °F (0 °C - 50 °C).
• Store and use the inverter in a cool and dry environment.
• Avoid exposing the inverter to heating elements, direct sunlight, or high
humidity.
Problem
No AC output -
Red LED lit.
No AC output -
Green LED not lit.
Motorized power
tool will not operate
Suggested Solutions
Possible Cause
K01-0000376-03
Note Page
Model
Input Voltage
Output Peak Power
Output Continuous Power
Output Voltage
Output USB Voltage
Output Frequency
Output Waveform
Input Fuse (Internal)
Input Fuse (Cigar plug)
Protection Features
CPS480TG2U /B
11 to 15 volts
480 Watts
400 Watts
120 Volts
5 Volts
60 Hz
Simulated Sine Wave
25Amp x2
20Amp
Overload, Overvoltage,
Overheating, Short-circuit
DC Fuse Replacement
Specifications
Troubleshooting
Product Registration
Technical Support
Legal notices (FCC Part 15)
1. Turn off the inverter and disconnect any devices from the inverter.
2. Disconnect the inverter from power source and remove the leads.
3. Pull the fuse straight out of the holder.
4. Replace with a new 25-amp fuse in the inverter body or a 20-amp fuse
located inline on the cigar plug cable.
1. Bad connection
or wiring.
2. Fuse is blown.
1. DC input is below 11
Vdc / Over 15Vdc.
2. Short circuit.
3. Overload.
4. Inverter hot.
1. Check your battery volts
and recharge or replace
the battery.
2. Disconnect the load.
3. Reduce the load.
4. Disconnect the load and
operate the inverter for a
few minutes.
1. Tighten all DC connections.
2. Check fuse and replace or
Call Service.
Excessive startup load.
If the start up load
exceeds the inverters
peak load capability it
will not work.
Disconnect the load until the
inverter operates normally
and connect the load again.
2 Year Limited Warranty
CyberPower warrants this CPS480TG2U (the "Inverter") to be free from material /B
and manufacturing defects for two years. If a defect results in product failure during
its normal use, CyberPower’s sole responsibility is to repair or replace (at its sole
option) the Inverter.
The foregoing Limited Warranty is the consumer’s sole and exclusive remedy and
excludes any incidental or consequential damages. Some States do not allow the
exclusion of limitation of incidental and consequential damages. It is possible that the
above limitations or exclusions may not apply to you (the Consumer). This limited
warranty gives the Consumer specific legal rights and the Consumer may have other
rights, which vary from State to State.
To make a Limited Warranty claim:
1. Pack and ship the Inverter to CyberPower at 4241 12th Avenue East, Suite 400,
Shakopee, MN 55379.
2. Clearly indicate on the outside of the packaging that this is a “WARRANTY RETURN”.
3. Clearly include your name and address (a) on the outside packaging and (b) on a
sheet of paper enclosed in the box with the Inverter that is being returned.
4. You MUST prepay all shipping costs and you are responsible for packaging
and shipment.
CAUTION: Any changes or modifications not expressly approved by the guarantee
of this device could void the user’s authority to operate the equipment.
Thank you for purchasing a CyberPower product. Prompt product registration entitles
coverage under the Limited Warranty and also allows the opportunity to be notified of
product enhancements, upgrades, and other announcements.
Registration is quick and easy. Go to Product Registration page at
www.cyberpowersystems.com.
Feel free to contact our Tech Support department with installation, troubleshooting, or
general product questions.
CyberPower Technical Support
Phone: 1-877-297-6937
Email: tech@cpsww.com
Web: www.cyberpowersystems.com
Address: 4241 12th Ave. E., STE 400, Shakopee, MN 55379
Hours of Operation: Monday – Friday, 7:00am – 6:00pm (CST)
This equipment has been tested and found to comply with the limits for a Class B Digital Device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more of the following
measures: (1) Reorient or relocate the receiving antenna. (2) Increase the separation between the
equipment and receiver. (3) Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected. (4) Consult the dealer or an experienced radio/TV technician for
help. Any special accessories needed for compliance must be specified in the instruction.
CAUTION: A shielded-type power cord is required in order to meet FCC emission limits and
also to prevent interference to the nearby radio and television reception. It is essential that only the
supplied power cord be used. Use only shielded cables to connect I/O devices to this equipment.
Cyber Power Systems (USA), Inc.
4241 12th Avenue East, Suite 400, Shakopee, MN 55379
TEL: (952) 403-9500 Toll-Free: (877) 297-6937
FAX: (952) 403-0009 E-mail: sales@cpsww.com
www.cyberpowersystems.com
© 2018 Cyber Power Systems (USA), Inc.
All rights reserved. Reproduction in whole or in part without permission is prohibited.
Cigar Plug Cable
Fuse Holder
20 amp Fuse
25 amp Fuse
Inverter Body
Figure 1. Fuse Replacement
The CPS480TG2U inverter contains protection fuses. Two on the /B
inverter body and the other on the cigar plug cable (see Figure 1) to
protect the unit against overloading. If the inverter draws more than 150
watts via the cigar plug connection, or more than 480 watts via the battery
clamp connection, the internal fuse may open to protect the inverter,
vehicle battery, and the connected equipment. To replace the fuse,
please follow the instructions below:


Product specificaties

Merk: CyberPower
Categorie: Accu
Model: PowerTrip CPS480TG2U

Heb je hulp nodig?

Als je hulp nodig hebt met CyberPower PowerTrip CPS480TG2U stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Accu CyberPower

Handleiding Accu

Nieuwste handleidingen voor Accu

Bolt

Bolt CBP-U Handleiding

16 December 2024
Bolt

Bolt PP-5800BP Handleiding

13 December 2024
Bolt

Bolt PP-500DR Handleiding

13 December 2024
PAG

PAG MPL99 Handleiding

10 December 2024
PAG

PAG MPL50 Handleiding

10 December 2024
Apc

Apc RBC27 Handleiding

2 December 2024
Apc

Apc RBC24 Handleiding

2 December 2024
Apc

Apc RBC18 Handleiding

2 December 2024
Apc

Apc RBC44 Handleiding

2 December 2024