Renata ICP501022UPM Handleiding
Lees hieronder de π handleiding in het Nederlandse voor Renata ICP501022UPM (13 pagina's) in de categorie Accu. Deze handleiding was nuttig voor 2 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/13
Renata SA Tel. +41 (0)61 975 75 75 sales@renata.com
CH-4452 Itingen/Switzerland Fax. +41 (0)61 975 75 95 www.renata.com
The information and recommendations set forth are made in good faith and believed to be accurate as of the date of preparation. RENATA S.A. makes no warranty, expressed or implied, with
respect to this information and disclaims all liabilities from reliance on it.
Article Safety Data Sheet - Lithium Ion Polymer Batteries: 2019-01-29 Page 1 of 13
Article Safety Data Sheet - Lithium Ion/Polymer Batteries
Edition date: 29. January 2019
Version: 2019-01-29
Valid: as from 01. January 2019
RENATA SA
Kreuzenstrasse 30
CH-4452 ITINGEN / Switzerland
Tel: +41 61 975 75 75
Fax: +41 61 975 75 95
Section I - Product identification
Product Name: Nominal Voltage: 3.7 VLithium-ion Polymer Battery Pack
(Rechargeable Single Cell Battery)
Models: ICP / AHB Series see Annex I (Pouch cell construction)
Chemical System: Lithium - Graphit - Cobalt oxide
Section II - Hazardous ingredients
IMPORTANT NOTE: The battery should not be opened or exposed to heat because exposure of the following
ingredients contained within could be harmful under some circumstances.
Chemical Name CAS No. Content % of total weight
LiCoO2 12190-79-3 29.36 - 35.88
Carbon black 1333-86-4 15.26 - 18.66
Aluminium 7429-90-5 13.14 - 16.06
Copper 7440-50-8 7.08 - 8.66
Ethylene carbonate 96-49-1 4.55 - 5.57
Nylon 3.47 - 4.24
Ethyl methyl carbonate 623-53-0 3.45 - 4.21
Diethyl carbonate 105-58-8 3.36 - 4.10
Polyethylene 9002-88-4 3.26 - 3.98
Polypropylene 9003-07-0 2.40 - 2.94
Poly(vinyliden difluoride) 24937-79-9 2.11 - 2.57
Lithium hexafluorophosphate 21324-40-3 1.64 - 2.00
Nickel 7440-02-0 0.54 - 0.66
Polyester 0.13 - 0.15
Polyimide 0.09 - 0.11
Activated Carbon 7440-44-0 0.08 - 0.10
Acrylic 0.05 - 0.07
Oxalic acid 00144-62-7 0.04 - 0.06
Renata SA Tel. +41 (0)61 975 75 75 sales@renata.com
CH-4452 Itingen/Switzerland Fax. +41 (0)61 975 75 95 www.renata.com
The information and recommendations set forth are made in good faith and believed to be accurate as of the date of preparation. RENATA S.A. makes no warranty, expressed or implied, with
respect to this information and disclaims all liabilities from reliance on it.
Article Safety Data Sheet - Lithium Ion Polymer Batteries: 2019-01-29 Page 2 of 13
1) This Article Safety Data Sheet is provided as a service to our customers.
Based on the definition of the term 'article' in the Occupational Safety and Health Administration (OSHA) Hazard Communication Standard, 29
CFR Subpart 1910.1200, there is no requirement for a Material Safety Data Sheet (MSDS) for lithium Ion Polymer Batteries. Notification is not
required because these products are 'articles' that do not release a covered toxic chemical under the normal conditions of processing or use.
Disclaimer:
The batteries are exempt articles and are not subject to hazard Communication Standard Requirement. This
sheet is provided as technical information only. The information contained in this Product Safety Data Sheet
has been established to the best of RENATA SA's knowledge and belief. RENATA SA makes no
representation and provides no warranty or guarantee regarding the contents of this Product Safety Data
Sheet and excludes its liability, express or implied.
Section III - Possible Hazards
Cells or Batteries may explode when placed in a fire, when exposed to excessive heat, when opened or
during inappropriate use; which could release hydrogen fluoride gas and smoke.
Use only suitable extinguishing media.
The chemicals mentioned in Section II are contained in a sealed can.
Risk of exposure occurs only if the battery is mechanically or electrically abused
(see Safety precautions in Section VII).
The most likely risk is acute exposure when a cell vents or opened, can cause irritation when inhaled.
Carcinogenicity - NTP: NO
Carcinogenicity - lARC: NO
Carcinogenicity - OSHA: NO
Contact with electrolyte with skin and eyes should be avoided.
3.2 Risk and Safety sentences:
(1) Nature of special risks :β
R14 Reacts with water
R21 Harmful in contact with skin
R22 Harmful is swallowed
R41 Risk of serious damage to the eye
R42/43 May cause sensitization by inhalation and skin contact
R43 May cause sensitization by skin contact
(2) Safety advices :β
S2 Keep out of reach from children
S8 Keep away from moisture
S22 Do not breathe dust
S24 Avoid contact with skin
S26 In case of contact with eyes, rinse immediately with plenty of water
and get medical advice / attention
S36 Wear suitable protective clothing
S37 Wear suitable gloves
Renata SA Tel. +41 (0)61 975 75 75 sales@renata.com
CH-4452 Itingen/Switzerland Fax. +41 (0)61 975 75 95 www.renata.com
The information and recommendations set forth are made in good faith and believed to be accurate as of the date of preparation. RENATA S.A. makes no warranty, expressed or implied, with
respect to this information and disclaims all liabilities from reliance on it.
Article Safety Data Sheet - Lithium Ion Polymer Batteries: 2019-01-29 Page 3 of 13
3.3 EU-GHS Classification:
Hazard statements:
H302 Harmful if swallowed
H312 Harmful in contact with skin
H315 Causes skin irritation
H318 Causes serious eye damage
H332 Harmful if inhaled
Precautionary statements:
P102 Keep out of reach of children
P223 Keep away from any possible contact with water, because of violent reaction and
possible flash fire
P232 Protect from moisture
P260 Do not breathe dust/fume/gas/mist/vapors/spray
P262 Do not get in eyes, on skin, or on clothing
P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact
lenses, if present and easy to do. Continue rinsing
P280 Wear protective gloves / protective clothing / eye protection / face protection
Section IV - First Aid Procedures
None unless internal material exposure.
Explanation Carcinogenicity: NOT RELEVANT
Skin contact with contents of an opened battery can cause irritation, wash immediately with soap and water. Remove
contaminated clothing. If irritation persists, get medical help
Eye contact:
Contents of an opened battery can cause severe irritation, IMMEDIATELY FLUSH THOROUGHLY WITH COPIOUS
AMOUNTS OF WATER FOR AT LEAST 15 MINUTES. SEEK MEDICAL ATTENTION.
Ingestion:
CALL MEDICAL PRACTIONER IMMEDIAIELY
Inhalation:
Do not inhale leaked material. PROVIDE IMMEDIATELY FRESH AIR, IF IRRITATION PERSISTS, GET MEDICAL
HELP.
Section V - Fire Fighting Instructions
5.1 Fire and explosion hazard:
The battery can leak and/or spout vaporized or decomposed and combustible
electrolyte fumes in case of exposure above 70 resulting from inappropriate use orβ
the environment.
Cells or batteries may flame or leak potentially hazardous organic vapors if exposed
to excessive heat or fire. Fire, excessive heat, or over voltage conditions may
produce hazardous decomposition products.
Damaged or opened cells or batteries can result in rapid heating and the release of
flammable vapors.
Vapors may be heavier than air and may travel along the ground or be moved by
ventilation to an ignition source and flash back fire, excessive heat, or over voltage
conditions may produce hazardous decomposition products.
During water application, caution is advised as burning pieces of flammable particles may be ejected from
the fire.
Product specificaties
Merk: | Renata |
Categorie: | Accu |
Model: | ICP501022UPM |
Heb je hulp nodig?
Als je hulp nodig hebt met Renata ICP501022UPM stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Accu Renata
29 Januari 2025
28 Juni 2023
28 Juni 2023
28 Juni 2023
28 Juni 2023
28 Juni 2023
26 Juni 2023
24 Juni 2023
22 Juni 2023
Handleiding Accu
- Accu Bosch
- Accu Sony
- Accu Panasonic
- Accu Nikon
- Accu Epson
- Accu LG
- Accu Huawei
- Accu Canon
- Accu DeWalt
- Accu JVC
- Accu A-solar
- Accu Abus
- Accu Aluratek
- Accu Ansmann
- Accu Apc
- Accu Arris
- Accu Belkin
- Accu BlackVue
- Accu Digitus
- Accu DJI
- Accu Einhell
- Accu Energizer
- Accu Fein
- Accu Fluke
- Accu Fujifilm
- Accu Fuxtec
- Accu Gardena
- Accu Greenworks
- Accu Hama
- Accu Hikoki
- Accu Hikvision
- Accu HQ
- Accu Husqvarna
- Accu Kensington
- Accu Kress
- Accu Leica
- Accu McCulloch
- Accu Mestic
- Accu Metabo
- Accu Milwaukee
- Accu Monacor
- Accu Nedis
- Accu Neewer
- Accu Parkside
- Accu Powerplus
- Accu Ranex
- Accu Ryobi
- Accu Sennheiser
- Accu Skil
- Accu Stiga
- Accu Stihl
- Accu Stinger
- Accu Targus
- Accu Toa
- Accu Toolcraft
- Accu Trust
- Accu Variotek
- Accu Varta
- Accu Vetus
- Accu Vonroc
- Accu Watson
- Accu Worx
- Accu Xtorm
- Accu Zipper
- Accu Ozito
- Accu Black And Decker
- Accu Sandberg
- Accu Shure
- Accu Nitecore
- Accu Petzl
- Accu Cocraft
- Accu Carat
- Accu Hilti
- Accu Conrad
- Accu Cobra
- Accu Biltema
- Accu Cramer
- Accu EGO
- Accu Techly
- Accu Deltaco
- Accu Scosche
- Accu Cortina
- Accu Duracell
- Accu PNY
- Accu Tripp Lite
- Accu Valcom
- Accu Whistler
- Accu Victron Energy
- Accu Energenie
- Accu Thomann
- Accu CyberPower
- Accu SKROSS
- Accu Growatt
- Accu Lenmar
- Accu HΓ€hnel
- Accu Berg
- Accu Speed-Link
- Accu For_Q
- Accu Genaray
- Accu Wentronic
- Accu Anton/Bauer
- Accu Impact
- Accu Arctic Cooling
- Accu Crestron
- Accu Bolt
- Accu Team Orion
- Accu SolarEdge
- Accu Venom
- Accu Inovonics
- Accu Anova
- Accu Red Power
- Accu Sungrow
- Accu Ultron
- Accu Enphase
- Accu E-flite
- Accu PowerDrive
- Accu LSI
- Accu Fxlion
- Accu PowerBass
- Accu SOUNDBOKS
- Accu FeinTech
- Accu Verico
- Accu Levolta
- Accu HART
- Accu APSystems
- Accu TCW Technologies
- Accu Enerdrive
- Accu Tecnoware
- Accu Ventev
- Accu PAG
Nieuwste handleidingen voor Accu
24 December 2024
24 December 2024
24 December 2024
16 December 2024
13 December 2024
13 December 2024
13 December 2024
10 December 2024
10 December 2024
2 December 2024