Quick Start Guide 930466A
The IP Endpo int Company
1.0 Out-of-Box and Prior to Final Installation
1.1. Verify that you have received all of the parts listed on the Installation Quick
Reference placemat.
1.2. Download the current manual, otherwise known as an Operation Guide,
which is available on the Documentation page at the following website
address:
http://www.cyberdata.net/products/voip/digitalanalog/ceilingspkr2ptt/docs.html
Note You can also navigate to the Documentation page by going to
www.CyberData.net and following the steps that are indicated by
the following figures:
2.0 Select Power Source
PoE Switch PoE Injector
Set PoE power type to Class 0 = 15.4W CAT6 cable recommendedā€”
for longer distances
Be sure you are using a non-PoE switch or port
Make sure port is not in trunk mode
Set port to full duplex/ 100mbps
Spanning Tree Protocol (STP) must be disabled or Portfast enabled
2
3
1
VoIP V2 Ceiling Speaker, Push-to-Talk,
Quick Start Guide
Quick Start Guide 930466A
3.0 Power Test
3.1. Plug in the CyberData device and monitor the LED activity on the front of
the device. See the following figure:
3.2. The GREEN power/status LED and the YELLOW network LED come on
immediately. The YELLOW network LED will blink to indicate network
traffic. After about 27 seconds, the GREEN power/status LED will blink
twice to indicate that the board is fully booted.
If there is no DHCP server available on the network, it will try 12 times with
a three second delay between tries and eventually fall back to the
programmed static IP address (by default 10.10.10.10). This process will
take approximately 80 seconds.
3.3. When the device has completed the initialization process, press and hold the
RTFM switch for 3 seconds to announce the IP address.
This concludes the power test. Go to Section 4.0, "Connecting to a Network
in a Test Environment".
Speaker
Status
(Green LED)
Network
Link/Activity
(Yellow LED)
Quick Start Guide 930466A
4.0 Connecting to a Network in a Test Environment
Note The following connections are usually needed for this procedure:
ā€¢ PC
ā€¢ PoE switch or injector
ā€¢ CyberData device
4.1. In a test environment, use a PC that is connected to the same switch as a
single CyberData device. Note the subnet of the test PC.
4.2. Use the CyberData Discovery Utility program to locate the device on the
network. You can download the Discovery Utility program from the
following website address:
http://www.cyberdata.net/support/voip/discovery_utility.html
4.3. Wait for initialization to complete before using the Discovery Utility
program to scan for a device. The device will show the current IP address,
MAC address, and serial number.
4.4. Select the device.
Note If the IP address of the device is in the same subnet of the PC, then
go to Step 4.7.
4.5. If the IP address of the device is different from the subnet of the PC, then
complete the following steps:
4.5.1. Click the Details tab.
4.5.2. Click Adv. Config to manually configure settings with an available IP
address in the same subnet.
Note A gateway address of 0.0.0.0 or a subnet address of
255.255.255.255 will prompt you to enter a valid address.
4.5.3. Click OK after you are finished making changes.
4.6. A dialog box will prompt you to click OK after confirming the configuration
changes and will ask you to wait while the device reboots. Please wait for
the device to power up and wait for the Discovery Utility program to find
the device on the network.


Product specificaties

Merk: CyberData Systems
Categorie: Speaker
Model: 011180
Kleur van het product: Grey, White
Breedte: 228.6 mm
Diepte: 228.6 mm
Hoogte: 60.96 mm
Connectiviteitstechnologie: Bedraad
Ethernet LAN: Ja
Type stroombron: Power over Ethernet (PoE)
Gemiddeld vermogen: - W
Certificering: FCC B, UL 60950
Aanbevolen gebruik: Overige
Impedantie: - Ohm
Geschikt voor buitengebruik: Nee
Audio-uitgangskanalen: 1.0 kanalen
Speaker plaatsing: Plafond-montage
Aantal drivers: 1
Peak Music Power Output (PMPO): 10 W
Frequentiebereik: - Hz
Gevoeligheid: 96 dB
Luidspreker soort: 1-weg
Speaker omsluiting: Gesloten
Bedrijfstemperatuur (T-T): -10 - 50 Ā°C