Crestron IRP2 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Crestron IRP2 (2 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 205 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/2
Additional Resources
Visit the product page on the Crestron website (www.crestron.com)
for additional information and the latest rmware updates. Use a QR
reader application on your mobile device to scan the QR image.
Description
The Crestron® IRP2 is a pure IR (infrared) emitter that is designed to adhere to the IR
sensor window of a television, an optical disc player, or any other IR-controllable device.
The IRP2 connects to any Crestron control system or room solution box that is equipped
with a 2-pin terminal block-type Crestron IR port, providing a 1-way IR control interface
to the device.
IRP2
IR Emitter Probe
Installation Guide
Installation
Positioning the IRP2
With many devices, the IRP2 works best when positioned directly over the controlled
device’s IR sensor, but with other devices, operation is more consistent when the IRP2 is
placed an inch or two offset from the IR sensor.
It may be difcult to locate the IR sensor on the controlled device, so instead, test
commands from the Crestron control system or room solution box while moving the IRP2
around the controlled device’s front panel. When operation is consistent and reliable,
attach the IRP2 using the procedure below.
Attaching the IRP2
Peel off the clear adhesive strip on the back of the IRP2 shell, and then carefully afx the
IRP2 to the desired location on the controlled device’s front panel while pressing rmly.
Attaching the IR Mask (Optional)
Attach the included IR mask when two or more identical components in the same rack
are being controlled. The IR mask prevents stray IR output from accidentally controlling
another device.
To attach the IR mask, t the two pieces together without removing the clear adhesive
strips from the IRP2 shell or the IR mask, and then attach the IRP2 to the controlled
device as described above.
IRP2 Shell and (Optional) IR Mask (Side View)
Clear adhesive
layer
Internal IR
emitter
IR
output
IR
output
IRP2
shell
Miniwire
lead
NOTE:
If the IRP2’s shell must be removed and repositioned for any reason, it may
be necessary to replace the adhesive strip with a new piece of two-sided tape
(supplied) to restore adhesion.
NOTE:
The IRP2 is a pure infrared emitter, and it does not emit visible light. Since IR
can be recorded by using a smart device’s digital camera, test to see that the IRP2 is
properly working by triggering the IRP2 using the control system or room solution
box. While the IRP2 is being triggered, record a video of the emitter with a smart
phone’s digital camera. If IR is visible in the video during playback, the IRP2 is
properly working.
IR
mask
(optional)
Clear adhesive
layer
As of the date of manufacture, the device has been tested and found to comply with
specications for CE marking.
Product warranty can be found at www.crestron.com/warranty.
The specic patents that cover Crestron products are listed at patents.crestron.com.
Certain Crestron products contain open source software. For specic information, please visit
www.crestron.com/opensource.
Crestron and the Crestron logo are either trademarks or registered trademarks of Crestron
Electronics, Inc. in the United States and/or other countries. Other trademarks, registered
trademarks, and trade names may be used in this document to refer to either the entities claiming
the marks and names or their products. Crestron disclaims any proprietary interest in the marks
and names of others. Crestron is not responsible for errors in typography or photography.
This document was written by the Technical Publications department at Crestron.
©2016 Crestron Electronics, Inc.
Crestron Electronics, Inc. Installation Guide - DOC. 8186D
15 Volvo Drive, Rockleigh, NJ 07647 (2002188)
Tel: 888.CRESTRON 12.16
Fax: 201.767.7576 Specifications subject to
www.crestron.com change without notice.
Hardware Hookup
Insert the IRP2’s 2-pin connector into an infrared-serial output port of a control system
or a room solution box as shown in the following illustration.
IRP2 Connection Diagram
NOTE: The white-traced wire is positive (+) and connects to the pin labeled “S.”
Hardware Hookup
2-pin connector
IR port
(S G S G)
IR sensor
window
Optical Disk Player
Crestron DM-RMC-200-C


Product specificaties

Merk: Crestron
Categorie: Niet gecategoriseerd
Model: IRP2

Heb je hulp nodig?

Als je hulp nodig hebt met Crestron IRP2 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Crestron

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd

Festo

Festo VPPI Handleiding

21 November 2024
Festo

Festo SFAB Handleiding

21 November 2024
Festo

Festo SFAH Handleiding

21 November 2024
Festo

Festo DRRD-12 Handleiding

21 November 2024
Festo

Festo SDE3 Handleiding

21 November 2024
Festo

Festo SFTE Handleiding

21 November 2024