Crestron DSP-1282 Handleiding


Lees hieronder de đź“– handleiding in het Nederlandse voor Crestron DSP-1282 (2 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 82 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/2
DO GUIDE
NOTE: Ensure that the computer that is running the Crestron Avia Audio tool and the DSP are on the same subnet.
Observe the following when connecting devices that are equipped with Dante
® network capability (DSP-1281 and DSP-1283):
• DANTE PRI ports should be connected to a gigabit switch serving the primary Dante network.
• (Optional) DANTE SEC ports should be connected to a gigabit switch serving the secondary Dante network.
• The primary Dante network should never mix with the secondary Dante network.
If unbalanced connections are required, refer to the following diagrams.
Front Panel
CAUTION: When connecting a Windows® 7 or Windows 8 computer to the COMPUTER port for the rst time, make sure the computer has a live connection
to the Internet. For more information, refer to Answer ID 5745 in the Online Help section of the Crestron website (support.crestron.com).
NOTE: The front panel’s COMPUTER port can be used to directly connect a computer running the Crestron Avia Audio tool, bypassing the LAN connection.
DSP-860/DSP-1280/DSP-1281/DSP-1282/DSP-1283
Crestron AviaTM Digital Signal Processors
The Crestron Avia™ DSP-860, DSP-1280, DSP-1281, DSP-1282, and DSP-1283 series of digital signal processors are functionally similar with varying
capabilities. For simplicity within this guide, the term “DSP” is used except where noted.
DO Install the Device
These devices occupy 1U of rack space. Use a #1 Phillips screwdriver to attach the two included rack ears to the device, and then mount the device into the
rack using four mounting screws (not included).
DO Connect the Device
Make the necessary connections as called out in the following diagrams. Connect power last.
Rear Panel
DO Check the Box
QUANTITY ITEM PART NUMBER
2 Bracket, Rack Ear, 1U 2032122
1 Cable, USB 2.0, A - B, 6’ (1.83 m) 2014966
1 Power Cord, 6' 7" (2 m) 2001134
DSP-860 Only
14 Connector, 3-Pin 2003575
DSP-1280, DSP-1281, DSP-1282, and DSP-1283 Only
20 Connector, 3-Pin 2003575
DSP-860
MIC/LINE INPUTS:
From microphone or
other audio sources
LINE OUTPUTS:
To audio ampliers or
other mixer inputs
POWER:
From
ac power outlet
LAN:
10/100/1000BASE-T
Ethernet to LAN
Ground
DSP-1280
MIC/LINE INPUTS:
From microphone or
other audio sources
LINE OUTPUTS:
To audio ampliers or
other mixer inputs
POWER:
From
ac power outlet
LAN:
10/100/1000BASE-T
Ethernet to LAN
Ground
DSP-1281
MIC/LINE INPUTS:
From microphone or
other audio sources
LINE OUTPUTS:
To audio ampliers or
other mixer inputs
DANTE PRI:
To primary
DANTE™ network
POWER:
From
ac power outlet
LAN:
10/100/1000BASE-T
Ethernet to LAN
DANTE SEC:
To secondary DANTE network
Ground
DSP-1282
MIC/LINE INPUTS:
From microphone or
other audio sources
LINE OUTPUTS:
To audio ampliers or
other mixer inputs
LAN:
10/100/1000BASE-T
Ethernet to LAN
VOIP:
To VOIP network
USB:
To Crestron RL® system or third-party
USB host device
POWER:
From
ac power outlet
PHONE:
To phone line
Ground
USB:
To Crestron RL system or third-
party USB host device
DANTE PRI:
To primary
DANTE network
DANTE SEC:
To secondary
DANTE network
MIC/LINE INPUTS:
From microphone or
other audio sources
LINE OUTPUTS:
To audio ampliers or
other mixer inputs
LAN:
10/100/1000BASE-T
Ethernet to LAN
VOIP:
To VOIP network
PHONE:
To phone line
POWER:
From
ac power outlet
DSP-1283
Ground
COMPUTER:
Direct computer connection to device
DSP-1281 and DSP-1283
Unbalanced Input Wiring
Signal
Jumper
Ground Signal Shield
Unbalanced Output Wiring
DO GUIDE DOC. 7647G (2040694) 06.18
Specications subject to change without notice.
DO Download the Crestron Avia Audio Tool
DSPs use the Crestron Avia Audio tool for conguration and operation. Download the Crestron Avia Audio tool from .www.crestron.com/software
DO Congure the Device
Once the DSPs are connected to the same subnet as the host PC running the Crestron Avia Audio tool, start the Crestron Avia Audio tool and perform the
following:
1. Click Add New Network DSP, located in the left-hand work space.
2. Click to launch the device discovery function. A list of units found on the subnet is displayed. Ethernet
NOTE: If a DSP is not listed, verify that all connections have been made and that all devices and the computer running the Crestron Avia Audio tool are on the
same subnet.
DO Operate the Device
Apply Power
When power is applied to the device, the LED on the front panel displays the following:PWR
• Green - Normal operation.
• Amber - Device is booting up.
• Amber/Green (Cycling) - No network connection.
Adjust Settings
Use the Crestron Avia Audio tool to control the device.
NOTE: When connecting to the DSP over Ethernet, ensure that the computer and device are on the same subnet.
Monitor Input and Output Levels (DSP-1281 and DSP-1283 Only)
Use the front panel’s analog VU meters to monitor input and output levels.
Reset the Device
Press on the front panel to restart the device.RESET
DO Connect to Crestron XiO Cloud Service (Optional)
The Crestron XiO Cloud™ service allows supported Crestron devices across an enterprise to be managed and congured from one central and secure
location in the cloud. Supported devices are precongured to connect to the service. Use of the service requires a registered Crestron XiO Cloud account.
NOTE: The device can be disconnected from the service from the tab in Crestron Toolbox™ software ( > Cloud Services Functions Device Info > Cloud
Services). For details, refer to the Crestron Toolbox help le.
To connect the device to the Crestron XiO Cloud service:
1. Record the MAC address and serial number that are labeled on the shipping box or rear panel of the device. The MAC address and serial number
are required in order to add the device to the Crestron XiO Cloud environment.
2. Do either of the following:
• Access the Crestron XiO Cloud service at https://portal.crestron.io.
• Register for a Crestron XiO Cloud account at www.crestron.com/xiocloud.
For detailed information about using the Crestron XiO Cloud service, refer to the Crestron XiO Cloud Service User Guide (Doc. 8214) at
www.crestron.com/manuals.
As of the date of manufacture, the products have been tested and found to comply with specications for CE marking.
This product is Listed to applicable UL® Standards and requirements tested by Underwriters Laboratories Inc.
Ce produit est homologué selon les normes et les exigences UL applicables par Underwriters Laboratories Inc.
Federal Communications Commission (FCC) Compliance Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following conditions:
(1) This device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired
operation.
CAUTION: Changes or modications not expressly approved by the manufacturer responsible for compliance could void the user’s authority to operate the
equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
FCC Compliance Information (DSP-1283 and DSP-1282 only)
• Consult the dealer or an experienced radio/TV technician for help.
• This equipment complies with Part 68 of Federal Communications Commission (FCC) rules and requirements adopted by America’s Carriers
Telecommunications Association (ACTA). Each registered interface has a label that contains, among other information, a product identier in the format
US: CT UMM00BDMPS3300AEC. If requested, provide this information to the telephone company.
• If this equipment causes harm to the telephone network, the telephone company may temporarily discontinue service. If possible, advance notication is
given; otherwise, notication is given as soon as possible. The telephone company will advise the customer of the right to le a complaint with the FCC.
• The telephone company may make changes in its facilities, equipment, operations, or procedures that could affect the proper operation of this equipment.
Advance notication and the opportunity to maintain uninterrupted service are given.
• If experiencing difculty with this equipment, please contact manufacturer for repair and warranty information. The telephone company may require this
equipment to be disconnected from the network until the problem is corrected, or it is certain the equipment is not malfunctioning.
• This unit contains no user-serviceable parts.
• This equipment is designed to connect to the telephone network or premises wiring using an FCC-compatible modular jack, which is compliant with Part
68 and requirements adopted by ACTA.
• The ringer equivalence number (REN) is useful in determining the quantity of devices you may connect to your telephone line and still have all of those
devices ring when your number is called. In most areas, the sum of the RENs of all devices should not exceed ve. To be certain of the number of devices
you may connect to your line as determined by the REN, call your telephone company to determine the maximum REN for your calling area.
• This equipment may not be used on coin service provided by the telephone company. Connection to party lines is subject to state tariffs. Contact your
state public utility commission or corporation commission for information.
Industry Canada (IC) Compliance Statement
CAN ICES-3(B)/NMB-3(B)
REN IC 0.1 (DSP-1283 and DSP-1282 only)
This product meets the applicable Industry Canada technical specications.
The Ringer Equivalence Number (REN) is an indication of the maximum number of devices allowed to be connected to a telephone interface. The termination of
an interface may consist of any combination of devices subject only to the requirement that the sum of the RENs of all the devices not exceed ve.
Le présent matériel est conforme aux specications techniques applicables d’Industrie Canada. L’indice d’équivalence de la sonnerie (IES) sert à indiquer le
nombre maximal de terminaux qui peuvent être raccordés à une interface téléphonique. La terminaison d’une interface peut consister en une combinaison
quelconque de dispositifs, à la seule condition que la somme d’indices d’équivalence de la sonnerie de tous les dispositifs n’excède pas cinq.
ACTA Compliance Information
REN US 0.1B (DSP-1283 and DSP-1282 only)
The Ringer Equivalence Number (REN) indicates the maximum number of devices allowed to be connected to a telephone interface. The termination of an
interface may consist of any combination of devices subject only to the requirement that the sum of the RENs of all the devices not exceed ve.
Rack Mounting Safety Precautions
•Elevated Operating Ambient Temperature: If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment
may be greater than room ambient temperature. Therefore, consideration should be given to installing the equipment in an environment compatible with
the maximum ambient temperature (Tma) specied by the manufacturer.
• : Installation of the equipment in a rack should be such that the amount of airow required for safe operation of the equipment is not Reduced Airow
compromised.
•Mechanical Loading: Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading.
• : Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits Circuit Overloading
might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this
concern.
•Reliable Earthing: Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other
than direct connections to the branch circuit (e.g., use of power strips).
Electrical Connection
“This product must be connected to an earthed mains socket-outlet.”
• Finland: “Laite on liitettävä suojamaadoituskoskettimilla varustettuun pistorasiaan.”
• : “Apparatet må tilkoples jordet stikkontakt.”Nor way
• : “Apparaten skall anslutas till jordat uttag.”Sweden
The specic patent s that cover Crestron product s are listed at . www.crestron.com/legal/patents
The product warranty can be found at .www.crestron.com/legal/sales-terms-conditions-warranties
Cert ain Crestron products cont ain open source sof tware. For specic information, visit . www.crestron.com/legal/open-source- soft ware
Crest ron, the Crestron logo, Crest ron Avia, Crest ron RL, Crestron Toolbox, and Crest ron XiO Cloud are either trademarks or regist ered t rademarks of Crest ron Electronics, Inc., in t he United States
and/or other countries. Dant e is either a t rademark or registered trademark of Audinate Pt y Ltd. in t he United St ates and/or ot her countries. Windows is either a trademark or registered t rademark
of Microsof t Corporation in the United States and/or ot her count ries. UL and t he UL logo are either trademarks or registered t rademarks of Underwriters Laboratories, Inc. in the United States and/
or ot her countries. Other trademarks, regist ered t rademarks, and t rade names may be used in t his document to refer to eit her t he entit ies claiming the marks and names or t heir products. Crestron
disclaims any propriet ary int erest in t he marks and names of ot hers. Crestron is not responsible f or errors in t ypography or photography.
This document was written by the Technical Publications department at Crestron. ©2018 Crestron Electronics, Inc.
DO Learn More
Visit the website for additional information and the latest rmware updates. To learn more about this product, use a QR reader application on
your mobile device to scan the QR images.
Crestron Electronics
15 Volvo Drive, Rockleigh, NJ 07647
888.CRESTRON | www.crestron.com


Product specificaties

Merk: Crestron
Categorie: Niet gecategoriseerd
Model: DSP-1282
Kleur van het product: Black, Grey
Gewicht: 4100 g
Breedte: 439 mm
Diepte: 365 mm
Hoogte: 44 mm
LED-indicatoren: Ja
Maximum resolutie: - Pixels
Ingang stroom: Ja
Ethernet LAN, data-overdrachtsnelheden: 10,100,1000 Mbit/s
Reset button: Ja
Rack-montage: Ja
Ethernet interface type: Gigabit Ethernet
RJ-45 ports hoeveelheid: 2
Warmtedissipatie: 102 BTU/h
Rackcapaciteit: 1U
AC-ingangsspanning: 100-240 V
AC-ingangsfrequentie: 50 - 60 Hz
Stroomverbruik (typisch): 30 W
Bedrijfstemperatuur (T-T): 5 - 40 °C
Relatieve vochtigheid in bedrijf (V-V): 10 - 90 procent
Vermogenstoevoer locatie: Achter

Heb je hulp nodig?

Als je hulp nodig hebt met Crestron DSP-1282 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Crestron

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd