Claypaky Skylos Handleiding


Lees hieronder de đź“– handleiding in het Nederlandse voor Claypaky Skylos (20 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 7 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/20
USER INFORMATION
Congratulations on choosing a Claypaky product!
We thank you for your custom.
Please note that this product, as all the others in the rich
Claypaky range, has been designed and made with total quality
to ensure excellent performance and best meet your
expectations and requirements.
INDEX
Page Contents
2 1. Safety information
4 2. Unpacking and preparation
6 3. Installation and start-up
6 3.1 Installing the fixture
6 3.2 Connecting to mains supply
7 3.3 Connecting the control signal line: DMX / Art-Net
8 3.4 Switching on the fixture and basic SetUp
9 4. Dimensions
ENGLISH
CJ3004
SKYLOS
2
SKYLOS
1. SAFETY INFORMATION
* see at page 10 for other languages
Please read this document carefully and keep it for future reference. Claypaky disclaims any liability for damage to the
appliance or property or injury to third parties resulting from installation, use or service that is not carried out in
accordance with the instructions in this document and in the instruction manual. The instruction manual may be
downloaded from the website www.claypaky.com and must be kept with the appliance. Claypaky reserves the right to
modify the instructions and specifications shown in its documentation at any time without notice.
• Installation
Make sure all parts for fixing the luminaire are in a good state of repair. Make sure the point of anchorage is stable
before positioning the luminaire. The safety chain must be properly hooked onto the fitting and secured to the
framework, so that, if the primary support system fails, the fitting falls as little as possible. If the safety chain gets
used, it needs to be replaced with a genuine spare.
• Photobiological safety
This product includes a light source based on laser diodes. It complies with the requirements of clause 4.4 of the
laser safety standard IEC 60825-1:2014 (3rd edition), hence:
• It is a “laser product designed to function as conventional luminaire” as defined in the clause 4.4 itself, so it is
classified as CLASS 1 LASER PRODUCT according to IEC 60825-1:2014.
• Photobiological risk classification is performed according to the standard IEC 62471:2006, for conventional
luminaires, using 2013 ICNIRP exposure limits, resulting in a Risk Group 3 (RG3).
Class 1 Laser product (IEC 60825-1:2014) - RG3 (IEC 62471:2006)
• Possibly hazardous optical radiation emitted from this product.
• Do not look at operating lamp source, closer than the Hazard Distance. Eye injury may result.
• Caution - Use of controls or adjustments or performance of procedures other than those specified herein may
result in hazardous light exposure.
• The US Food and Drug Administration (FDA) requires this product to be purchased and operated in the US under
the terms of a permit. This permit which is issued by the FDA at no cost is called a variance. See variance
document for required procedures.
• All operators must be a legal employee of the variance holder and have completed a simple training course
including safety and operation.
• Operators shall control access to the beam within the hazard distance or install the product at the height that will
prevent spectators’ eyes from being within the hazard distance.
• The luminaire is in excess of the Exempt Risk Group; the viewer-related risk is dependent upon how the user
install and use the product.
Hazard distances (depending on settings):
see operating procedure for more information
This Laser Product is designated as Class 1 / RG3 during all procedures of operation.
• Do not operate with personnel exposure shorter than the declared hazard distance due to risk of skin or corneal burns.
• The unit is never to be operated if defective or the covers or seals are damaged.
• No maintenance is required by the user.
• The user must not modify the unit or remove protective covers or housings except for service: potentially
hazardous Class 3B Laser light is accessible if service procedures are not followed.
• Service is only to be performed by trained and authorized personnel. Refer to Service Manual for detailed safety information.
HD = 215ft. (65m.)
HD = 165ft. (50m.)
HD = 130ft. (40m.)
HD = 82ft. (25m.)
HD = 16ft. (5m.)
3
SKYLOS
Do not stare at the operating light source
The luminaire should be positioned so that prolonged staring into the luminaire at a distance closer than 660 m is
not expected.
Do not operate without complete light source enclosure in place or when lenses are damaged. Lenses and housing
must be mounted and, if visibly damaged, they have to be replaced with genuine spares to avoid exposure to
potentially hazardous internal laser light levels.
Caution, risk of electric shock
The light source contained in this luminaire shall only be replaced by the manufacturer or his service agent or a
similar qualified person.
Connection to mains supply
Connection to the electricity mains must be carried out by a qualified electrical installer. Check that the mains
frequency and voltage correspond to those for which the luminaire is designed as given on the electrical data label.
This label also gives the input power to which you need to refer to evaluate the maximum number of fittings to
connect to the electricity line, in order to avoid overloading.
IMPORTANT: if the luminaire is used in residential environment, in some case might be necessary to adopt
appropriate measures to avoid EMI disturbances to broadcast receiver equipment.
Protection against electrical shock
Connection must be made to a power supply system fitted with efficient earthing (Class I appliance according to
standard EN 60598-1). It is, moreover, recommended to protect the supply lines of the luminaires from indirect
contact and/ or shorting to earth by using appropriately sized residual current devices.
Maximum ambient temperature
Do not operate the fixture if the ambient temperature (Ta) exceeds 45° C (113° F).
Temperature of the external surface
The maximum temperature that can be reached on the external surface of the fitting, in a thermally steady state, is
55°C (131°F).
IP66 protection rating
The fitting is fully protected against dust (first digit 6) and against powerful jets of water (second digit 6).
Minimum distance of illuminated objects
The luminaire needs to be positioned so that the objects hit by the light beam are at least 30 meters (98'5'') from the lens
of the luminaire. For personnel exposure distances, refer to Hazard Distances declared above.
Minimum distance from flammable materials
The luminaire must be positioned so that any flammable materials are at least 0.2 meters (8”) from every point on
the surface of the luminaire.
Light collimation system
This product contains internal light collimation system. Avoid intense light from any angle.
This product is intended for the following areas of application:
studios, stages, theatres, exhibitions, trade fairs, events, theme parks, entertainment venues, architectural lighting
and similar.
Not suitable for household illumination
Not for residential use
Battery
This product contains a rechargeable battery. To preserve the environment, please dispose the battery at the end
of its life according to the regulation in force.
Disposing
This product is supplied in compliance with European Directive 2012/19/EU - Waste Electrical and Electronic
Equipment (WEEE). To preserve the environment please dispose/recycle this product at the end of its life according
to the local regulation.
The products to which this manual refers comply with the European Directives pursuant to:
• 2014/53/EU - Radio Equipment Directive (RED)
• 2011/65/EU - Restriction of the use of certain hazardous substances (RoHS)
• 2009/125/EC - EcoDesign requirements for Energy-related Products (ErP)
ta 45°C
tc 55°C
IP66
30