Clas Ohlson UNI-T UT133B Handleiding
Clas Ohlson
Multimeter
UNI-T UT133B
Lees hieronder de đ handleiding in het Nederlandse voor Clas Ohlson UNI-T UT133B (64 pagina's) in de categorie Multimeter. Deze handleiding was nuttig voor 119 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/64
Eng lishSve nsk aNo r skSuo miDeu ts ch
UNI-T UT133B
Multimeter
Multimeter UNI-T UT133B
UNI-T UT133B multimeter
Yleismittari UNI-T UT133B
Art.no. Model
36-7745 UT133B Ver. 20190705
3
Eng lis h
UNI-T Multimeter
Art.no 36-7745 Model UT133B
Please read theîentire instruction manual before using theîproduct and then save
it for future reference. We reserve theîright for any errors in text or images and any
necessary changes made to technicalîdata. In theîevent of technical problems
or other queries, please contact our Customer Services (see address details on
theîback).
Information about this measuring instrument
This multimeter has been constructed and tested in accordance with theîrequirements
of Measurement Category III (CAT III) up to 600 V nominal voltage and Pollution
Degreeî2.
Categorisation
Measuring instruments are classiďŹed into categories according to what kind of
electrical environment they can be used in and how safe/protective they are at
withstanding overvoltages.
The Measurement Category of theîinstrument will be marked on theîratingîplate.
The Measurement Category indicates how capable theîinstrument is of withstanding
overvoltages which could be dangerous for theîuser.
In brief, theîcategorisation can be described like this:
⢠In theîevent of aîsudden overvoltage on theîpower grid (aîtransient energy spike
from aîlightning strike for example) theîdanger is greatest at theîpoint where
theîpower supply service cable enters aîbuilding.
⢠Further in theîbuilding, theîresistance (impedance) in theîmains supply
cables increases and connected appliances and devices reduce and divide
theîovervoltage. Therefore, theîMeasurement Category (also called Overvoltage
Installation Category) of theîmeasuring instrument indicates which electrical
environment theîinstrument is designed to be usedîin.
The categories that measuring instruments are classiďŹed into are:
⢠CAT : For measuring electronics and products that have aîbuilt-in protection I
from overvoltage.
⢠CAT : For measuring single-phase equipment connected to aîhousehold mains II
supply, both through wall sockets and ďŹxed installation.
⢠CAT : For measuring electrical wiring installed in buildings. Examples are III
measurements on ďŹxed installation cables and hard-wired appliances, socket
outlets, circuit breakers and distribution boards. Three-phase distribution (all
supply cables and 3-phase equipment, machines and appliances).
⢠CAT : Three-phase at theîutility connection and any outdoor conductors.IV
This multimeter is rated as CAT III and is approved for measuring voltages up to
600îV on single-phase products. Thisîmultimeter must not be used for measuring
three-phase equipment, three-phase cables or distribution boards even if
theînominal voltage is not higher than 600îV.
Product specificaties
Merk: | Clas Ohlson |
Categorie: | Multimeter |
Model: | UNI-T UT133B |
Heb je hulp nodig?
Als je hulp nodig hebt met Clas Ohlson UNI-T UT133B stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Multimeter Clas Ohlson
8 Juli 2023
4 Juli 2023
26 Juni 2023
6 Mei 2023
Handleiding Multimeter
- Multimeter Abus
- Multimeter Aldi
- Multimeter Alecto
- Multimeter Altai
- Multimeter Amiko
- Multimeter Amprobe
- Multimeter Appa
- Multimeter Basetech
- Multimeter Beha-Amprobe
- Multimeter Benning
- Multimeter Brandson
- Multimeter Brennenstuhl
- Multimeter Bruder Mannesmann
- Multimeter Digitus
- Multimeter Elma
- Multimeter Elro
- Multimeter Extech
- Multimeter Ferm
- Multimeter Flir
- Multimeter Fluke
- Multimeter Gembird
- Multimeter Gossen Metrawatt
- Multimeter Greenlee
- Multimeter Hager
- Multimeter Hubinont
- Multimeter Ideal
- Multimeter Keithley
- Multimeter Kingcraft
- Multimeter Laserliner
- Multimeter Mastech
- Multimeter Maxwell
- Multimeter Megger
- Multimeter Metrel
- Multimeter Metrix
- Multimeter Micronta
- Multimeter Milwaukee
- Multimeter Monacor
- Multimeter Parkside
- Multimeter PCE Instruments
- Multimeter Perel
- Multimeter Plieger
- Multimeter Powerfix
- Multimeter Profile
- Multimeter Sanwa
- Multimeter Schneider
- Multimeter Silverline
- Multimeter Skandia
- Multimeter Stanley
- Multimeter TFA
- Multimeter Topcraft
- Multimeter Uni-T
- Multimeter Velleman
- Multimeter Voltcraft
- Multimeter Wiha
- Multimeter Workzone
- Multimeter Joy-it
- Multimeter Jung
- Multimeter Steren
- Multimeter Klein Tools
- Multimeter EMOS
- Multimeter Tacklife
- Multimeter Biltema
- Multimeter REV
- Multimeter Etekcity
- Multimeter Testo
- Multimeter Somogyi
- Multimeter Testboy
- Multimeter Yato
- Multimeter Wago
- Multimeter GW Instek
- Multimeter Kyoritsu
- Multimeter Owon
- Multimeter Projecta
- Multimeter Cablexpert
- Multimeter HĂśgert
- Multimeter Multimetrix
- Multimeter Digi-tool
- Multimeter Kewtech
- Multimeter Sonel
- Multimeter Testec
- Multimeter Vimar
- Multimeter Strex
- Multimeter PeakTech
- Multimeter MBS
- Multimeter MGL Avionics
- Multimeter Rigol
- Multimeter Chauvin Arnoux
- Multimeter Aim TTi
- Multimeter CEM
- Multimeter Horex
- Multimeter Cosinus
- Multimeter Kurth Electronic
- Multimeter Weltron
- Multimeter Rohde & Schwarz
- Multimeter EEVBlog
- Multimeter WeidmĂźller
- Multimeter HT Instruments
- Multimeter Caltek
- Multimeter Elworks
- Multimeter Qian
- Multimeter Bearware
- Multimeter Noyafa
Nieuwste handleidingen voor Multimeter
18 November 2024
18 November 2024
18 November 2024
17 November 2024
17 November 2024
14 November 2024
11 November 2024
22 Oktober 2024
16 Oktober 2024
16 Oktober 2024