Americas Headquarters:
Cisco Systems, Inc., 170 West Tasman Drive, San Jose, CA 95134-1706 USA
Cisco UCS B200 M3 Blade Server Installation and
Service Note
The Cisco UCS B200 M3 (shown in Figure 1) is the latest Cisco Intel-based, half-width blade supporting
two CPU sockets using Intel E5-2600 series CPUs and up to 24 DIMMs; it supports one modular LOM
(dedicated slot for Cisco's Virtual Interface Card) and one adapter card. At this time, the UCS B200 M2
(second generation) server is still available and is documented elsewhere. You can install up to eight
UCS B200 Blade Servers to a UCS chassis, mixing with other models or Cisco UCS blade servers in the
chassis if desired. The Cisco UCS B200 M3 is managed by Cisco UCS Manager version 2.0(2m) and
later.
Figure 1 Cisco UCS B200 M3 Front Panel
1 Asset tag 1
1.Each server has a blank plastic tag that pulls out of the front panel which is provided so that you can add your own
asset tracking label without interfering with the intended air flow.
7 Network link status LED
2 Blade ejector handle 8Blade health LED
3 Ejector captive screw 9Console connector
4 Hard drive bay 1 10 Reset button access
5 Hard drive bay 2 11 Beaconing LED and button
6 Power button and LED
UCS B200 M3
1 2 3 6 78 9 10 11
54
331360
2
Cisco UCS B200 M3 Blade Server Installation and Service Note
OL-26624-01
LEDs
Server LEDs indicate whether the blade server is in active or standby mode, the status of the network
link, the over all health of the blade server, and whether the server is set to give a flashing blue beaconing
indication. See Table 1 for details.
The removable hard disks also have LEDs indicating hard disk access activity and hard disk health.
Buttons
The Reset button is just inside the chassis and must be pressed using the tip of a paper clip or a similar
item. Hold the button down for five seconds, and then release it to restart the server if other methods of
restarting are not working.
Table 1 Blade Server LEDs
LED Color Description
Power Off Power off.
Green Normal operation.
Amber Standby.
Link Off None of the network links are up.
Green At least one network link is up.
Health Off Power off.
Green Normal operation.
Amber Minor error.
Blinking
Amber
Critical error.
Beaconing Off Beaconing not enabled.
Blinking
blue 1 Hz
Beaconing to locate a selected blade—If the LED is not
blinking, the blade is not selected. You can initiate
beaconing in UCS Manager or with the button.
Activity
(Disk Drive)
Off Inactive.
Green Outstanding I/O to disk drive.
Flashing
Amber
4 Hz
Rebuild in progress. Health LED will flash in unison.
Flashing
Amber
4 hz
Identify drive active.
Health
(Disk Drive)
Off Can mean either no fault detected or the drive is not
installed.
Flashing
Amber
4 hz
Identify drive active. If the Activity LED is also flashing
amber, a drive rebuild is in progress.
Amber Fault detected.
3
Cisco UCS B200 M3 Blade Server Installation and Service Note
OL-26624-01
The beaconing function for an individual server may get turned on or off by pressing the combination
button and LED. See Table 1 for details.
The power button and LED allows you to manually take a server temporarily out of service but leave it
in a state where it can be restarted quickly. If the desired power state for a service profile associated with
a blade server or an integrated rack-mount server is set to "off", using the power button or Cisco UCS
Manager to reset the server will cause the desired power state of the server to become out of sync with
the actual power state and the server may unexpected shutdown at a later time. To safely reboot a server
from a power-down state, use the Boot Server action in Cisco UCS Manager.
Connectors
The console port allows a direct connection to a blade server to allow operating system installation and
other management tasks to be done directly rather than remotely. The port uses the KVM dongle cable
(N20-BKVM shown in Figure 2) which provides a connection into a Cisco UCS blade server; it has a a
DB9 serial connector, a VGA connector for a monitor, and dual USB ports for a keyboard and mouse.
With this cable, you can create a direct connection to the operating system and the BIOS running on a
blade server. A KVM cable sh ade chassis accessory kit.ips standard with each bl
Figure 2 KVM Cable for Blade Servers
Conventions
This document uses the following conventions for notes, cautions, and safety warnings.
Notes and Cautions contain important information that you should know.
Note Means reader take note. Notes contain helpful suggestions or references to material that are not covered
in the publication.
Caution Means reader be careful. You are capable of doing something that might result in equipment damage or
loss of data.
1 3Connector to blade server slot VGA connection for a monitor
2 4DB9 serial connector 2-port USB connector for a mouse and keyboard
192621
1
23
4
Product specificaties
Merk: | Cisco |
Categorie: | Server |
Model: | UCS B200 M3 |
Kleur van het product: | Zilver |
Gewicht: | 4360 g |
Breedte: | 203 mm |
Diepte: | 620 mm |
Hoogte: | 50 mm |
Processorfamilie: | Intel |
Temperatuur bij opslag: | -40 - 65 °C |
Processor socket: | LGA 2011 (Socket R) |
Systeembus: | 8 GT/s |
Maximum intern geheugen: | 768 GB |
On-board graphics adapter model: | Matrox G200 |
Luchtvochtigheid bij opslag: | 5 - 93 procent |
ECC: | Ja |
Geheugen form factor: | 240-pin DIMM |
Chipset moederbord: | Intel C600 |
Ondersteunde opslagstationinterfaces: | Serial Attached SCSI (SAS),Serial ATA III |
Soorten RAID: | 0,1 |
Compatibele processors: | Intel® Xeon® |
Aantal ondersteunde processoren: | 2 |
Intel® Xeon series: | E5-2600 |
Aantal DIMM sloten: | 24 |
Aantal storage drives ondersteund: | 2 |
Opslagschijf afmetingen ondersteund: | 2.5 " |
Ondersteunde geheugen types: | DDR3-SDRAM |
Hot-swap HDD bays: | Ja |
Bedrijfstemperatuur (T-T): | 10 - 35 °C |
Relatieve vochtigheid in bedrijf (V-V): | 5 - 93 procent |
Code geharmoniseerd systeem (HS): | 84714100 |
Heb je hulp nodig?
Als je hulp nodig hebt met Cisco UCS B200 M3 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Server Cisco
15 Juni 2023
6 Mei 2023
24 April 2023
21 April 2023
11 April 2023
28 Maart 2023
18 Maart 2023
18 Maart 2023
16 Maart 2023
26 Februari 2023
Handleiding Server
- Server HP
- Server Sony
- Server Asus
- Server Medion
- Server Toshiba
- Server Abus
- Server Acer
- Server Acti
- Server Allnet
- Server Apc
- Server Axis
- Server Buffalo
- Server D-Link
- Server Dell
- Server Digi
- Server Digitus
- Server Dual Bay
- Server Eaton
- Server Elac
- Server EMC
- Server Fantec
- Server Flir
- Server Freecom
- Server Fujitsu
- Server GeoVision
- Server Gigabyte
- Server Hikvision
- Server Ibm
- Server In Win
- Server Iomega
- Server Kathrein
- Server LaCie
- Server Lenovo
- Server LevelOne
- Server Linksys
- Server Luxman
- Server Maxdata
- Server Megasat
- Server Monacor
- Server MSI
- Server Nec
- Server Netgear
- Server Provision ISR
- Server QNAP
- Server Quantum
- Server Revox
- Server Seagate
- Server Sitecom
- Server Sun
- Server Synology
- Server Technics
- Server Trendnet
- Server Veritas
- Server Western Digital
- Server ZyXEL
- Server Conceptronic
- Server Atlona
- Server SilverStone
- Server Intel
- Server SIIG
- Server Tripp Lite
- Server Valcom
- Server Matrox
- Server Asustor
- Server Gefen
- Server Planet
- Server Intellinet
- Server Silex
- Server Supermicro
- Server G-Technology
- Server Lindy
- Server AVerMedia
- Server Black Box
- Server Blackmagic Design
- Server ATen
- Server Extron
- Server Areca
- Server AMX
- Server SEH
- Server StarTech.com
- Server HGST
- Server Sonnet
- Server TAIDEN
- Server Advantech
- Server Moxa
- Server Smart-AVI
- Server Kramer
- Server KanexPro
- Server Avocent
- Server Vimar
- Server Hanwha
- Server Ernitec
- Server MvixUSA
- Server Promise Technology
- Server Raidsonic
- Server Rocstor
- Server Infortrend
- Server Opengear
- Server EXSYS
- Server Raritan
- Server Chenbro Micom
- Server Middle Atlantic
- Server Mr. Signal
- Server Atlantis Land
- Server C2G
- Server Lantronix
- Server IStarUSA
- Server NETSCOUT
- Server Mobotix
- Server Origin Storage
Nieuwste handleidingen voor Server
18 December 2024
18 December 2024
9 December 2024
7 December 2024
3 December 2024
3 December 2024
3 December 2024
2 December 2024
1 December 2024
1 December 2024