I N S T A L L A T I O N I N S T R U C T I O N S
Instrucciones de instalación
Installationsanleitung
Instruções de Instalação
Istruzioni di installazione
Installatie-instructies
Instructions d´installation
RPA Elite Series Projector Mounts
Spanish Product Description
German Product Description
Portuguese Product Description
Italian Product Description
Dutch Product Description
French Product Description
RPMA/RPMB/RPMC Series
RPMA/RPMB/RPMC Series Installation Instructions
2
NOTE: RPMA, RPMB, and RPMC models are included in
these installation instructions. Throughout these
instructions "RPMX" is used to designate all of the
models covered by these instructions.
DISCLAIMER
Milestone AV Technologies and its affiliated corporations and
subsidiaries (collectively "Milestone"), intend to make this
manual accurate and complete. However, Milestone makes no
claim that the information contained herein covers all details,
conditions or variations, nor does it provide for every possible
contingency in connection with the installation or use of this
product. The information contained in this document is subject
to change without notice or obligation of any kind. Milestone
makes no representation of warranty, expressed or implied,
regarding the information contained herein. Milestone assumes
no responsibility for accuracy, completeness or sufficiency of
the information contained in this document.
Chief® is a registered trademark of Milestone AV Technologies.
All rights reserved.
IMPORTANT SAFETY INSTRUCTIONS
WARNING: A WARNING alerts you to the possibility of
serious injury or death if you do not follow the instructions.
CAUTION: A CAUTION alerts you to the possibility of
damage or destruction of equipment if you do not follow the
corresponding instructions.
WARNING: Failure to read, thoroughly understand, and
follow all instructions can result in serious personal injury,
damage to equipment, or voiding of factory warranty! It is the
installer’s responsibility to make sure all components are
properly assembled and installed using the instructions
provided.
WARNING: Failure to provide adequate structural strength
for this component can result in serious personal injury or
damage to equipment! It is the installer’s responsibility to
make sure the structure to which this component is attached
can support five times the combined weight of all equipment.
Reinforce the structure as required before installing the
component.
WARNING:
Exceeding the weight capacity can result in
serious personal injury or damage to equipment! It is the
installer’s responsibility to make sure the combined weight of
all components attached to the RPMX does not exceed 50 lbs
(22.7 kg).
• The weight capacity of the RPMX may be LIMITED to
the lowest weight capacity of any other components
located between the RPMX and the supporting
structure!
WARNING: Use this mounting system only for its intended
use as described in these instructions. Do not use
attachments not recommended by the manufacturer.
WARNING: Never operate this mounting system if it is
damaged. Return the mounting system to a service center for
examination and repair.
WARNING: Do not use this product outdoors.
IMPORTANT ! : The RPMX mounts are designed to be:
• mounted to a 1-1/2" NPT or NPSM following ANSI/
ASME B1.20.1 (Schedule 40, 0.154" minimum
thickness aluminum - ASTM B221) threaded extension
column;
• mounted to double 2" x 4" wood stud cross bracing
(1-1/2" on center) between two 2" x 4" ceiling joists with
a maximum drywall covering of 5/8";
• mounted to a concrete ceiling with a minimum
thickness of 8" and a maximum drywall covering of
5/8"; or
• suspended from four #10-24 grade ASTM A307 or
better threaded rods (not included) which are secured
to unistrut, angle or channel assembly overhead
structural members (trusses or I-beams) by #10-24
grade ASTM A307 or better jam nuts (not included).
--SAVE THESE INSTRUCTIONS--
Installation Instructions RPMA/RPMB/RPMC Series
3
DIMENSIONS
TOOLS REQUIRED FOR INSTALLATION
PARTS
2.79
5.241.00
ROLL ADJUSTMENT
POINT
3
5.50
6.50
5.50
4.50
1.50" DIA NPT
SECURITY LOCK
SECURITY SWITCH
PITCH ADJUSTMENT
POINT
20
POINT 20
1/4" (6.4mm) dia. (concrete)
3/32" (2.4mm) dia. (wood)
5/32" - security
(included)
A (1)
[RPMA/-B/-C]
B (1)
[Example of SLM bracket]


Product specificaties

Merk: Chief
Categorie: Flat panel steun
Model: RPMB178
Kleur van het product: Zwart
Gewicht: 2721 g
Breedte: 65 mm
Diepte: 27 mm
Hoogte: 55 mm
Montagewijze: Plafond
Maximale gewichtscapaciteit: - kg

Heb je hulp nodig?

Als je hulp nodig hebt met Chief RPMB178 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Flat panel steun Chief

Chief

Chief K1D120BXDL Handleiding

17 November 2024
Chief

Chief RPMA204 Handleiding

17 November 2024
Chief

Chief LCB1U Handleiding

17 November 2024
Chief

Chief RPA640 Handleiding

17 November 2024
Chief

Chief FSBI2TB Handleiding

17 November 2024
Chief

Chief XCB1U Handleiding

17 November 2024
Chief

Chief RSA213 Handleiding

17 November 2024
Chief

Chief RSMBU Handleiding

17 November 2024
Chief

Chief VPAU Handleiding

23 Juni 2024

Handleiding Flat panel steun

Nieuwste handleidingen voor Flat panel steun