Chauvin Arnoux F604 Handleiding
Chauvin Arnoux
Multimeter
F604
Lees hieronder de 📖 handleiding in het Nederlandse voor Chauvin Arnoux F604 (29 pagina's) in de categorie Multimeter. Deze handleiding was nuttig voor 19 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/29

Clamp multimeter
EN - User’s manual
F604
3
0
0
0
A
2
0
0
0
A
1
0
0
0
V
C
A
T
I
V
1
5
0
0
V
C
A
T
I
I
I
COM +
1000 V CAT IV
1500 V CAT III
1700 V
1200 V
max
F604
AC/DC TRMS CLAMP METER
OFF
Ω
A
V
Adp
T °
°F
°C
P
AC DC
M MAX IN
kHz
kVA
%
0
°C°F
∆REL ∆Ref
kΩ
HOLD

2
WARNING, risk of DANGER ! The operator should refer to this user's manual whenever this danger symbol appears.
Application or withdrawal authorized on bare conductors carrying dangerous voltages. Type A current sensor as per
IEC/EN 61010-2-032 or BS EN 61010-2-032.
Battery.
Equipment protected throughout by double or reinforced insulation.
Earth.
The CE marking indicates compliance with the European Low Voltage Directive (2014/35/EU), Electromagnetic
Compatibility Directive (2014/30/EU), and Restriction of Hazardous Substances Directive (RoHS, 2011/65/EU and
2015/863/EU).
The UKCA marking certiîš¿es that the product is compliant with the requirements that apply in the United Kingdom,
in particular as regards Low-Voltage Safety, Electromagnetic Compatibility, and the Restriction of Hazardous
Substances.
AC - Alternating current.
AC and DC - Alternating and direct current.
The rubbish bin with a line through it indicates that, in the European Union, the product must undergo selective
disposal in compliance with Directive WEEE 2012/19/EU. This equipment must not be treated as household waste.
Deîš¿nitions of the measurement categories
îš„Measurement category IV corresponds to measurements taken at the source of low-voltage installations.
Example: power feeders, meters and protection devices.
îš„Measurement category III corresponds to measurements on building installations.
Example: distribution panel, circuit-breakers, machines or îš¿xed industrial devices.
îš„Measurement category II corresponds to measurements taken on circuits directly connected to low-voltage installations.
Example: power supply to domestic electrical appliances and portable tools.
You have just acquired an and we thank you.F604 clamp multimeter
For best results from your device:
îš„read this user manual attentively,
îš„observe the precautions for its use.

3
CONTENTS
1. DELIVERY CONDITION ......................................................................................................................................................4
2. PRESENTATION ..................................................................................................................................................................5
2.1. The switch ...................................................................................................................................................................6
2.2. The keys of the keypad 7 ...............................................................................................................................................
2.3. The display unit 8 ...........................................................................................................................................................
2.4. The terminals ...............................................................................................................................................................9
3. THE KEYS ...........................................................................................................................................................................10
3.1. HOLD key 10 ................................................................................................................................................................
3.2. key (second function) .................................................................................................................................... 11
3.3. key ................................................................................................................................................................. 11
3.4. MAX/MIN key ................................................................................................................................................................. 11
3.5. Hz key 12 .................................................................................................................................................................
3.6. key 13 .................................................................................................................................................................
4. USE ...................................................................................................................................................................................... 14
4.1. Commissioning 14 ..........................................................................................................................................................
4.2. Starting up the clamp multimeter 14 ...............................................................................................................................
4.3. Switching the clamp multimeter 14 .................................................................................................................................
4.4. Conîš¿guration .............................................................................................................................................................14
4.5. Voltage measurement (V) 16 ..........................................................................................................................................
4.6. Continuity test .................................................................................................................................................16
4.7. Resistance measurement Ω ......................................................................................................................................17
4.8. Diode test ........................................................................................................................................................17
4.9. Current measurement (A) 17 ..........................................................................................................................................
4.10. Starting current or over-current (True INRUSH) measurement 19 ...............................................................................
4.11. Frequency measurement (Hz) 19 .................................................................................................................................
4.12. Temperature measurement .....................................................................................................................................20
4.13. Adapter function measurement 21 ................................................................................................................................
5. CHARACTERISTICS .........................................................................................................................................................22
5.1. Reference conditions 22 .................................................................................................................................................
5.2. Characteristics under the reference conditions 22 .........................................................................................................
5.3. Environmental conditions 25 ..........................................................................................................................................
5.4. Characteristics of construction 25 ..................................................................................................................................
5.5. Power supply 26 .............................................................................................................................................................
5.6. Compliance with international standards 26 ...................................................................................................................
5.7. Variations in the domain of use 27 .................................................................................................................................
6. MAINTENANCE ..................................................................................................................................................................28
6.1. Cleaning 28 ....................................................................................................................................................................
6.2. Replacement of the batteries 28 .....................................................................................................................................
7. WARRANTY ........................................................................................................................................................................28
Product specificaties
Merk: | Chauvin Arnoux |
Categorie: | Multimeter |
Model: | F604 |
Heb je hulp nodig?
Als je hulp nodig hebt met Chauvin Arnoux F604 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Multimeter Chauvin Arnoux

29 December 2023

20 December 2023

20 December 2023

20 December 2023

20 December 2023

20 December 2023

20 December 2023

20 December 2023

20 December 2023

8 Juli 2023
Handleiding Multimeter
- Multimeter Abus
- Multimeter Aldi
- Multimeter Alecto
- Multimeter Altai
- Multimeter Amiko
- Multimeter Amprobe
- Multimeter Appa
- Multimeter Basetech
- Multimeter Beha-Amprobe
- Multimeter Benning
- Multimeter Brandson
- Multimeter Brennenstuhl
- Multimeter Bruder Mannesmann
- Multimeter Digitus
- Multimeter Elma
- Multimeter Elro
- Multimeter Extech
- Multimeter Ferm
- Multimeter Flir
- Multimeter Fluke
- Multimeter Gembird
- Multimeter Gossen Metrawatt
- Multimeter Greenlee
- Multimeter Hager
- Multimeter Hubinont
- Multimeter Ideal
- Multimeter Keithley
- Multimeter Kingcraft
- Multimeter Laserliner
- Multimeter Mastech
- Multimeter Maxwell
- Multimeter Megger
- Multimeter Metrel
- Multimeter Metrix
- Multimeter Micronta
- Multimeter Milwaukee
- Multimeter Monacor
- Multimeter Parkside
- Multimeter PCE Instruments
- Multimeter Perel
- Multimeter Plieger
- Multimeter Powerfix
- Multimeter Profile
- Multimeter Sanwa
- Multimeter Schneider
- Multimeter Silverline
- Multimeter Skandia
- Multimeter Stanley
- Multimeter TFA
- Multimeter Topcraft
- Multimeter Uni-T
- Multimeter Velleman
- Multimeter Voltcraft
- Multimeter Wiha
- Multimeter Workzone
- Multimeter Joy-it
- Multimeter Jung
- Multimeter Clas Ohlson
- Multimeter Steren
- Multimeter Klein Tools
- Multimeter EMOS
- Multimeter Tacklife
- Multimeter Biltema
- Multimeter REV
- Multimeter Etekcity
- Multimeter Testo
- Multimeter Somogyi
- Multimeter Testboy
- Multimeter Yato
- Multimeter Wago
- Multimeter GW Instek
- Multimeter Kyoritsu
- Multimeter Owon
- Multimeter Projecta
- Multimeter Cablexpert
- Multimeter Högert
- Multimeter Multimetrix
- Multimeter Digi-tool
- Multimeter Kewtech
- Multimeter Sonel
- Multimeter Testec
- Multimeter Vimar
- Multimeter Strex
- Multimeter PeakTech
- Multimeter MBS
- Multimeter MGL Avionics
- Multimeter Rigol
- Multimeter Aim TTi
- Multimeter CEM
- Multimeter Horex
- Multimeter Cosinus
- Multimeter Kurth Electronic
- Multimeter IWH
- Multimeter Weltron
- Multimeter Rohde & Schwarz
- Multimeter EEVBlog
- Multimeter Weidmüller
- Multimeter HT Instruments
- Multimeter Caltek
- Multimeter Elworks
- Multimeter Qian
- Multimeter Bearware
- Multimeter Noyafa
Nieuwste handleidingen voor Multimeter

21 December 2024

16 December 2024

7 December 2024

7 December 2024

5 December 2024

5 December 2024

3 December 2024

2 December 2024

1 December 2024

1 December 2024