Quick Reference Guide
English EN
Español ES
Français FR
Deutsch DE
Nederlands NL
Model ID: ROGUEOUTCAST1BEAM
1
EN
QUICK REFERENCE GUIDE
Rogue Outcast 1 Beam QRG Rev. 2
About This Guide
The Rogue Outcast 1 Beam Quick Reference Guide (QRG) has basic product information such as connection, mounting,
menu options, and DMX values. Download the User Manual from www.chauvetprofessional.com for more details.
Disclaimer
The information and specifications contained in this QRG are subject to change without notice.
LIMITED WARRANTY
FOR WARRANTY REGISTRATION AND COMPLETE TERMS AND CONDITIONS PLEASE VISIT OUR WEBSITE.
For Customers in the United States and Mexico: www.chauvetlighting.com/warranty-registration.
For Customers in the United Kingdom, Republic of Ireland, Belgium, the Netherlands, Luxembourg, France, and
Germany: www.chauvetlighting.eu/warranty-registration.
Chauvet warrants that this product shall be free from defects in material and workmanship under normal use, for the
period specified in, and subject to the exclusions and limitations set forth in the full limited warranty on our website. This
warranty extends only to the original purchaser of the product and is not transferable. To exercise rights under this
warranty, you must provide proof of purchase in the form of an original sales receipt from an authorized dealer that shows
the product name and date of purchase. THERE ARE NO OTHER EXPRESS OR IMPLIED WARRANTIES. This
warranty gives you specific legal rights. You may also have other rights that vary from state to state and country to
country. This warranty is valid only in the United States, United Kingdom, Republic of Ireland, Belgium, the Netherlands,
Luxembourg, France, Germany and Mexico. For warranty terms in other countries, please consult your local distributor.
Safety Notes
These Safety Notes include important information about installation, use, and maintenance.
• DO NOT open this product. It contains no user-serviceable parts.
• DO NOT look at the light source when the product is on.
• DO NOT operate this product if the housing, lenses, or cables appear damaged.
• DO NOT connect this product to a dimmer or rheostat.
• DO NOT leave any flammable material within 80 cm of this product while operating or connected to power.
• DO NOT submerge this product. Temporary outdoor operation is fine (IP65).
• Not for permanent outdoor installation in locations with extreme environmental conditions. This includes, but is not
limited to:
• Exposure to a marine/saline environment (within 3 miles of a saltwater body of water).
• Where the normal high or low temperatures of the location exceed the temperature ranges in this
manual.
• Locations that are prone to flooding or being buried in snow.
• Other areas where the product will be subject to extreme radiation or caustic substances.
• CAUTION: When transferring product from extreme temperature environments, (e.g. cold truck to warm humid
ballroom) condensation may form on the internal electronics of the product. To avoid causing a failure, allow
product to fully acclimate to the surrounding environment before connecting it to power.
• CAUTION: This product’s housing may be hot when lights are operating.
• USE a safety cable when mounting this product overhead.
• ONLY connect this product to a grounded and protected circuit.
• ONLY use the hanging/mounting bracket or the handles to carry this product. Do not carry by the moving head.
• To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely disconnect the
product from power via breaker or by unplugging it.
• Mount this product in a location with adequate ventilation, at least 20 in (50 cm) from adjacent surfaces.
• The maximum ambient temperature is 104 °F (40 °C). Do not operate this product at higher temperatures.
• The luminaire should be positioned so that prolonged staring into the luminaire at a distance closer than 34.4 ft
(10.5 m) is not expected.
• If the external flexible cable or cord of this luminaire is damaged, it shall be replaced by a special cord or cord
exclusively available from the manufacturer or his service agent.
• The light source contained in this luminaire shall only be replaced by the manufacturer or his service agent or a
similar qualified person.
• The luminaire is intended for professional use only.
• In the event of a serious operating problem, stop using immediately.
Contact
Outside the U.S., U.K., Ireland, Benelux, France, Germany, or Mexico, contact your distributor to request support or
return a product. Refer to Contact Us at the end of this QRG for contact information.
What is Included
• Rogue Outcast 1 Beam
• Seetronic Powerkon IP65 power cord
• 2 Omega brackets with mounting hardware
• Quick Reference Guide
EN
2
Rogue Outcast 1 Beam QRG Rev. 2
QUICK REFERENCE GUIDE
AC Power
This product has an auto-ranging power supply that can work with an input voltage range of 100–240 VAC, 50/60 Hz.
AC Plug
Replacing the Fuse
1. Disconnect the product from power.
2. Using a flat-head screwdriver, unscrew the fuse holder cap from the housing.
3. Remove blown fuse and replace with a good fuse of the same type and rating.
4. Screw the fuse holder cap back in place and reconnect power.
DMX Linking
The Rogue Outcast 1 Beam will work with a DMX controller using a 5-pin IP-rated DMX serial connection. A DMX Primer
is available from www.chauvetprofessional.com.
DMX Connection
The Rogue Outcast 1 Beam uses a 5-pin IP-rated DMX data connection for its DMX personalities: 16CH and 19CH. See
the User Manual for information about connecting and configuring the product for DMX operation.
RDM (Remote Device Management)
Remote Device Management, or RDM, is a standard for allowing DMX-enabled devices to communicate bi-directionally
along existing DMX cabling. Check the DMX controller’s User Manual or with the manufacturer, as not all DMX controllers
have this capability. The Rogue Outcast 1 Beam supports RDM protocol that allows feedback to make changes to menu
map options. Download the User Manual from www.chauvetprofessional.com for more details.
Mounting
Before mounting this product, read the Safety Notes. Use at least one mounting point per product. Make sure the
mounting clamps are capable of supporting the weight of the product. For Chauvet’s line of mounting clamps, go to
http://trusst.com/productcategory/truss-clamps/.
Mounting Diagram
Connection Wire (U.S.) Wire (Europe) Screw Color
AC Live Black Brown Yellow/Brass
AC Neutral White Blue Silver
AC Ground Green/Yellow Green/Yellow Green
To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely
disconnect the product from power via breaker or by unplugging it.
!
Safety cable
Mounting clamps (2x)
Overhead Mounting Floor Mounting
Mounting
brackets
(2x)


Product specificaties

Merk: Chauvet
Categorie: Niet gecategoriseerd
Model: Rogue Outcast 1 Beam

Heb je hulp nodig?

Als je hulp nodig hebt met Chauvet Rogue Outcast 1 Beam stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Chauvet

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd