Ovation H-55WW QRG Rev. 14
About This Guide
The Ovation H-55WW Quick Reference Guide (QRG) has basic product information such as connection, mounting, menu
options, and DMX values.
Disclaimer
The information and specifications contained in this QRG are subject to change without notice.
LIMITED WARRANTY
FOR WARRANTY REGISTRATION AND COMPLETE TERMS AND CONDITIONS PLEASE VISIT OUR WEBSITE.
For Customers in the United States and Mexico: www.chauvetlighting.com/warranty-registration.
For Customers in the United Kingdom, Republic of Ireland, Belgium, the Netherlands, Luxembourg, France, and
Germany: www.chauvetlighting.eu/warranty-registration.
Chauvet warrants that this product shall be free from defects in material and workmanship under normal use, for the
period specified in, and subject to the exclusions and limitations set forth in the full limited warranty on our website. This
warranty extends only to the original purchaser of the product and is not transferable. To exercise rights under this
warranty, you must provide proof of purchase in the form of an original sales receipt from an authorized dealer that shows
the product name and date of purchase. THERE ARE NO OTHER EXPRESS OR IMPLIED WARRANTIES. This
warranty gives you specific legal rights. You may also have other rights that vary from state to state and country to
country. This warranty is valid only in the United States, United Kingdom, Republic of Ireland, Belgium, the Netherlands,
Luxembourg, France, Germany and Mexico. For warranty terms in other countries, please consult your local distributor.
Safety Notes
• The luminaire should be positioned so that prolonged staring into the luminaire at a distance closer than 7.2 m is
not expected.
• If the external flexible cable or cord of this luminaire is damaged, it shall be replaced by a special cord or cord
exclusively available from the manufacturer or his service agent.
• The light source contained in this luminaire shall only be replaced by the manufacturer or his service agent or a
similar qualified person.
• The luminaire is intended for professional use only.
• DO NOT open this product. It contains no user-serviceable parts.
• To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely disconnect the
product from power via breaker or by unplugging it.
• DO NOT look at the light source when the product is on.
• CAUTION: This product’s housing may be hot when lights are operating.
• Mount this product in a location with adequate ventilation, at least 20 in (50 cm) from adjacent surfaces.
• DO NOT operate this product outdoors or in any location where dust, excessive heat, water, or humidity may affect
it. (IP20)
• DO NOT leave any flammable material within 50 cm of this product while operating or connected to power.
• CAUTION: When transferring product from extreme temperature environments, (e.g., cold truck to warm humid
ballroom) condensation may form on the internal electronics of the product. To avoid causing a failure, allow
product to fully acclimate to the surrounding environment before connecting it to power.
• USE a safety cable when mounting this product overhead.
• DO NOT operate this product if the housing, lenses, or cables appear damaged.
• DO NOT connect this product to a dimmer or rheostat.
• ONLY connect this product to a grounded and protected circuit.
• ONLY use the hanging/mounting bracket to carry this product.
• In the event of a serious operating problem, stop using immediately.
• The maximum ambient temperature is 113 °F (45 °C). Do not operate this product at higher temperatures.
FCC Compliance
This device complies with Part 15 Part B of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause undesired operation.
Any changes or modifications not expressly approved by the party responsible for compliance could void the user's
authority to operate the equipment.
RF Exposure Warning for North America, and Australia
Warning! This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This
equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body. This
transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Contact
Outside the U.S., U.K., Ireland, Benelux, France, Germany, or Mexico, contact your distributor to request support or
return a product. Refer to Contact Us at the end of this QRG for contact information.
EN
2
Ovation H-55WW QRG Rev. 14
QUICK REFERENCE GUIDE
What is Included
AC Power
This product has an auto-ranging power supply that can work with an input voltage range of 100–240 VAC, 50/60 Hz.
AC Plug
Replacing The Fuse
1. Disconnect this product from power.
2. Using a flat-head screwdriver, unscrew the fuse holder cap from the housing.
3. Remove blown fuse and replace with a good fuse of the same type and rating.
4. Screw the fuse holder cap back in place and reconnect power.
DMX Linking
The Ovation H-55WW will work with a DMX controller using a wireless, 5-pin DMX serial, or hard wire connection. A DMX
Primer is available from www.chauvetprofessional.com.
DMX Connection
The Ovation H-55WW uses a DMX connection for its DMX personalities: 1Ch 6Ch, 2Ch, 3Ch or .
DMX Hard-Wired Diagram
Master/Slave Connection
The Ovation H-55WW uses the DMX data connection for its Master/Slave mode.
RDM (Remote Device Management)
Remote Device Management, or RDM, is a standard for allowing DMX-enabled devices to communicate bi-directionally
along existing DMX cabling. Check the DMX controller’s User Manual or with the manufacturer as not all DMX controllers
have this capability. The Ovation H-55WW supports RDM protocol that allows feedback to make changes to menu map
options. Download the User Manual from www.chauvetprofessional.com for more details.
• Ovation H-55WW
• 65°, 40°, and 25° Lens
• 80° Filter
• Egg Crate
• Recess and Sconce Mounting Kits
• Quick Reference Guide
Connection Wire (U.S.) Wire (Europe) Screw Color
AC Live Black Brown Yellow/Brass
AC Neutral White Blue Silver
AC Ground Green/Yellow Green/Yellow Green
To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely
disconnect the product from power via breaker or by unplugging it.
!


Product specificaties

Merk: Chauvet
Categorie: Lamp
Model: Ovation H-55WW

Heb je hulp nodig?

Als je hulp nodig hebt met Chauvet Ovation H-55WW stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Lamp Chauvet

Handleiding Lamp

Nieuwste handleidingen voor Lamp