QUICK REFERENCE GUIDE
Maverick MK3 Profile QRG Rev. 4
About This Guide
The Maverick MK3 Profile Quick Reference Guide (QRG) has basic product information such as connection, mounting,
menu options, and DMX values. Download the User Manual from www.chauvetprofessional.com for more details.
Disclaimer
The information and specifications contained in this QRG are subject to change without notice.
LIMITED WARRANTY
FOR WARRANTY REGISTRATION AND COMPLETE TERMS AND CONDITIONS PLEASE VISIT OUR WEBSITE.
For Customers in the United States and Mexico: www.chauvetlighting.com/warranty-registration.
For Customers in the United Kingdom, Republic of Ireland, Belgium, the Netherlands, Luxembourg, France, and
Germany: www.chauvetlighting.eu/warranty-registration.
Chauvet warrants that this product shall be free from defects in material and workmanship under normal use, for the
period specified in, and subject to the exclusions and limitations set forth in the full limited warranty on our website. This
warranty extends only to the original purchaser of the product and is not transferable. To exercise rights under this
warranty, you must provide proof of purchase in the form of an original sales receipt from an authorized dealer that shows
the product name and date of purchase. THERE ARE NO OTHER EXPRESS OR IMPLIED WARRANTIES. This
warranty gives you specific legal rights. You may also have other rights that vary from state to state and country to
country. This warranty is valid only in the United States, United Kingdom, Republic of Ireland, Belgium, the Netherlands,
Luxembourg, France, Germany and Mexico. For warranty terms in other countries, please consult your local distributor.
Safety Notes
These Safety Notes include important information about installation, use, and maintenance.
• DO NOT open this product. It contains no user-serviceable parts.
• DO NOT look at the light source when the product is on.
• CAUTION: Flashing light is known to trigger epileptic seizures. User must comply with local laws regarding
notification of strobe use.
• To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely disconnect the
product from power via breaker or by unplugging it.
• CAUTION: When transferring product from extreme temperature environments, (e.g. cold truck to warm humid
ballroom) condensation may form on the internal electronics of the product. To avoid causing a failure, allow
product to fully acclimate to the surrounding environment before connecting it to power.
• CAUTION: This product’s housing may be hot when lights are operating.
• Mount this product in a location with adequate ventilation, at least 20 in (50 cm) from adjacent surfaces.
• DO NOT leave any flammable material within 50 cm of this product while operating or connected to power.
• USE a safety cable when mounting this product overhead.
• DO NOT operate this product outdoors or in any location where dust, excessive heat, water, or humidity may affect
it. (IP20)
• DO NOT operate this product if the housing, lenses, or cables appear damaged.
• DO NOT connect this product to a dimmer or rheostat.
• ONLY connect this product to a grounded and protected circuit.
• ONLY use the hanging/mounting bracket or the handles to carry this product.
• In the event of a serious operating problem, stop using immediately.
• The maximum ambient temperature is 113 °F (45 °C). Do not operate this product at higher temperatures.
FCC Compliance
This device complies with Part 15 Part B of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause undesired operation.
Any changes or modifications not expressly approved by the party responsible for compliance could void the user's
authority to operate the equipment.
RF Exposure Warning for North America, and Australia
Warning! This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This
equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body. This
transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Contact
Outside the U.S., United Kingdom, Ireland, Benelux, France, Germany, or Mexico, contact your distributor to request
support or return a product. Refer to Contact Us at the end of this QRG for contact information.
EN
2
Maverick MK3 Profile QRG Rev. 4
QUICK REFERENCE GUIDE
What is Included
AC Power
This product has an auto-ranging power supply that can work with an input voltage range of 100–240 VAC, 50/60 Hz.
AC Plug
Replacing the Fuse
1. Disconnect the product from power.
2. Using a flat head screwdriver, unscrew the fuse holder cap from the housing.
3. Remove blown fuse and replace with a good fuse of the same type and rating.
4. Screw the fuse holder cap back in place and reconnect power.
DMX Linking
The Maverick MK3 Profile will work with a DMX controller using a 3- or 5-pin DMX serial connection. A DMX Primer is
available from www.chauvetprofessional.com.
DMX Connection
The Maverick MK3 Profile uses a 3- or 5-pin DMX data connection for its DMX personalities: 38Ch and 54Ch. See the
User Manual for information about connecting and configuring the product for DMX operation.
Signal Connection
The Maverick MK3 Profile can link to controller software using an Ethernet connection. If using other Art-Net™ or sACN -
compatible products with the Maverick MK3 Profile, you can control each individually on a single network. See the User
Manual for information about how to connect and configure the product for these signals.
Art-Net™ Connection
Art-Net™ is an Ethernet protocol that uses TCP/IP which transfers a large amount of DMX512 data using an Neutrik®
etherCON® RJ45 connection over a large network. An Art-Net™ protocol document is available from
www.chauvetprofessional.com. Chauvet Professional recommends using unicast Art-Net™ for best results.
Art-Net™ designed by and copyright Artistic Licence Holdings Ltd.
sACN Connection
Also known as ANSI E1.31, Streaming-ACN is an Ethernet protocol that uses the layering and formatting of Architecture
for Control Networks to transport DMX512 data over IP or any other ACN compatible network.
RDM (Remote Device Management)
Remote Device Management, or RDM, is a standard for allowing DMX-enabled devices to communicate bi-directionally
along existing DMX cabling. Check the DMX controller’s User Manual or with the manufacturer as not all DMX controllers
have this capability. The Maverick MK3 Profile supports RDM protocol that allows feedback to make changes to menu
map options. Download the User Manual from www.chauvetprofessional.com for more details.
• Maverick MK3 Profile
• Seetronic Powerkon IP65 power cord
• 2 Omega Brackets with Mounting Hardware
• Quick Reference Guide
Connection Wire (U.S.) Wire (Europe) Screw Color
AC Live Black Brown Yellow/Brass
AC Neutral White Blue Silver
AC Ground Green/Yellow Green/Yellow Green
To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely
disconnect the product from power via breaker or by unplugging it.
!


Product specificaties

Merk: Chauvet
Categorie: Lamp
Model: Maverick MK3 Profile

Heb je hulp nodig?

Als je hulp nodig hebt met Chauvet Maverick MK3 Profile stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Lamp Chauvet

Handleiding Lamp

Nieuwste handleidingen voor Lamp