Chamberlain CLDM1 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Chamberlain CLDM1 (4 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 173 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/4
CLOSED
OPEN
Indoor Receiver
AC Adapter
Sensor
CR203 2
3 VOL TS
Lithium Battery
(CR2032 type)
Double-Sided
Fastening Strip
To prevent possible SERIOUS INJURY or DEATH from a closing garage
door:
• Activate door ONLY when it can be seen clearly, is properly adjusted,
and there are no obstructions to door travel.
• ALWAYS keep garage door in sight until completely closed. NEVER
permit anyone to cross path of closing garage door.
WARN
WARN
WARN
WARNWARNING
ING
ING
INGING
GARAGE DOOR
MONITOR SYSTEM
PRE-INSTALLATION SYSTEM TEST
1. The sensor and receiver are pre-matched (programmed) at the
factory. Test the system by flipping the sensor over while it is a
few feet away from the receiver. The receiver will show a
green light for closed when the sensor is face up in the vertical
position with the of the case pointing down round end
(Figure 1). The red light will flash when the sensor is face
down in the horizontal position (Figure 2).
2. If the green or the red receiver lights do not come on, or do
not react as described, see the Troubleshooting or Learning
section of these instructions.
®
INSTALLING THE BATTERY IN THE GARAGE
DOOR INDICATOR SENSOR
1. Place the screw driver blade on the tab at
the end of the case and gently press down
and in toward the case.
2. Insert the the lithium battery into the battery
clip with the + (positive) side face up.
3. Push the case back together tightly by
inserting the top hooks into the back cover,
then snap shut the bottom of
the case.
NOTE: It is normal to hear a rattle from the tilt switch in the sensor
when tilted or rotated to another position.
INDOOR RECEIVER SETUP
1. Plug the AC adapter into any
standard 110 volt AC electrical
wall outlet and the small plug
into the back of the indoor
receiver.
2. The receiver has a 9" antenna
wire which comes out the
back. The antenna should be
straight and not touching
metal.
3
V OL
TS
Figure 1 Figure 2
NOTE: Because radio control devices are inherently susceptible
to RF interference, this product should NOT be used as a
stand-alone security device. This product is considered a
monitoring and notification device ONLY, and as such, should not
be used as a substitute for a dedicated home security system.
To ensure that your Garage Door Monitor continues to operate
properly, the following checks should be performed on a
monthly basis:
• Check that the sensor is mounted properly on the garage door
(see Mounting the Sensor section of this manual.)
• Ensure the 3 volt lithium battery is installed properly.
• Check to see that the receiver system is plugged into a wall
outlet and the jack is properly connected to the back of the
receiver. Make sure the antenna is straight and not in contact
with any metal objects.
• Check that the receiver is properly recognizing sensor
signals (see Troubleshooting section of this manual.)
CL OSE D
OP
EN
Antenna Learn
Button
AC
Adapter
Location
Garage Door Monitor
Model CLDM1
MOUNTING THE SENSOR
Attach the sensor to the inside of the garage door using the
double-sided fastening strip. Mount the sensor near the top of the
garage door for best results. The round end of the case should
be pointing down when the garage door is closed.
Inside of Garage
Double-Sided Fastening Strip
Round End
Down
Know when your garage door is open
or closed!
Thank you for purchasing the Chamberlain Garage Door Monitor.
Monitor the status of your garage door from inside your home. No
longer will you have to run downstairs or go outside just to see if
you or your children have left the garage door open.
GARAGE DOOR MONITOR OPERATION
When the receiver is powered up, both red and green LED’s
will blink once. The receiver will then show a solid green LED
until it receives a signal from a programmed sensor. The receiver
will display the current status of the programmed door sensor. If
no door sensor(s) is programmed to the receiver, the green and
red LED will flash simultaneously. See Learning section.
The sensor sends a closed signal when the garage door is
closed (vertical) and an open signal as the sensor changes to
open (horizontal) position.
Up to 4 door mounted sensors will work in conjunction with one
receiver.
The red LED will blink once every half-second if one or more of
the programmed sensors are not in the closed position. The
green LED comes on steady only when all the programmed
sensors are in the closed position.
NOTE: The system will sometimes take a few seconds to send a
signal. The sensor updates the receiver by transmitting an open
or closed signal every few minutes.
LEARNING MORE THAN ONE SENSOR(S)
1. Door must be closed and the green
LED on steadily.
2. Press and hold the learn button for 2
seconds, the receiver will enter the learn
mode. The green LED will blink on and
off in 1/2 second increments.
3. The additional sensor(s) must be moved
from a vertical position to a horizontal
position or vice versa.
4. Both green and red LED’s will turn on for 1 second to indicate
a successful learn. Upon success, the receiver immediately
exits the learn mode and returns to normal operation.
5. If no signal is received within 30 seconds, the receiver will exit
the learn mode and return to normal operation.
ERASING OR CLEARING THE MEMORY
1. Unplug the small plug from the AC adapter on the
indoor receiver.
2. Make sure the AC adapter is plugged into a wall outlet.
3. To erase the memory of all programmed sensors, press and
hold the learn button while plugging the small plug on the AC
adapter into the indoor receiver.
4. Both red and green LED’s will blink simultaneously. This also
indicates that no sensor(s) are in memory.
5. Proceed to Step 2 of Learning More Than One Sensor to
program the sensor to the receiver.
TROUBLESHOOTING
The sensor battery must be replaced every year to assure
consistent operation. Flashing of the red and green LED’s in a
special sequence normally indicates intermittent operation or a
dead battery.
Loss of signal: The sensor sends a signal periodically to
synchronize to the receiver. Should the receiver not receive the
signal in approximately 20 minutes, the red and green LED’s will
blink as follows. The green LED will blink once, then the red LED
will blink one to four times depending upon the sensor
number. This indicates the receiver has not received the signal
from this sensor for over 20 minutes and therefore
requires attention.
If replacing the battery does not rectify the issue, move the
receiver into the garage for additional troubleshooting. If the
monitor works flawlessly in close proximity, the sensor(s) signal is
being either blocked or interfered with in the previous location
and may require placement in a room closer to the garage
door(s).
Garage Door Monitor system just installed:
The sensor and receiver set are factory coded prior to shipment
and should work out of the package. If you encounter a situation
where the sensor and receiver work properly upon initial
installation, but show a loss of signal after 20 minutes you may
have an additional factory code in the receivers memory. In this
instance, the receiver will then appear to be unresponsive to the
sensor. In this instance, do the following:
1. Clear Receiver Memory – See Erasing or Clearing the
Memory section. Upon clearing memory, the receiver will
power up and show simultaneously flashing green and red
LED’s – this indicates that memory is cleared.
2. Proceed to Step 2 of Learning More Than One Sensor. Note
that the procedures to learn 1 sensor or multiple sensors are
the same.
If the receiver is still showing a loss of signal after following the
above procedure, then the receiver is located too far away from
the sensor. Relocate the receiver closer to the sensor.
Garage Door Monitor suddenly malfunctions after working
properly:
The sensors battery power is low. Replace the battery.
OPTIONAL ACCESSORIES
You can purchase additional sensors if you have more than one
garage door. The receiver will learn up to 4 sensors and the red
light will blink if any one of the garage doors is open.
ITEM PART #
Sensor CLDM 2
Indoor Receiver 2C507-3
12 Volt AC Adapter 2C508-2
Specifications:
Sensor
Battery: Lithium Type 2032. 1 year life.
Temperature: -180F to 1400F (-250C to 600C).
Codes: 254 randomly set codes.
Receiver
Power Supply: 12 volt DC, 50 mA.
Temperature: 140F to 1220F (-100C to 500C).
Codes: Learns codes of up to 4 sensors
FOR SERVICE DIAL OUR TOLL FREE NUMBER:
1-800-528-9131
© 2004, Chamberlain Group Inc.
114A2628E All Rights Reserved
Press
and Hold
the Learn
Button
NOTICE: To comply with FCC and or Industry Canada (IC) rules, adjustment or modifications of
this receiver and/or transmitter are prohibited, except for changing the code setting or replacing
the battery. THERE ARE NO OTHER USER SERVICEABLE PARTS.
Tested to Comply with FCC Standards FOR HOME OR OFFICE USE. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired operation.
CLOSED
OPEN
Receptor Interior
Adaptador de CASensor
CR203 2
3 VOL TS
Pila de Litio
(tipo CR2032) Tira Sujetadora de Dos Lados
Para prevenir una LESIÓN GRAVE o la MUERTE de una puerta cerrante de un
garage:
• Active la puerta SOLO cuando pueda verse claramente, esté bien ajustada, y no
hay obstrucciones al recorrido de la puerta.
• SIEMPRE mantenga la puerta del garage a la vista hasta que esté
completamente cerrada. NUNCA permita que nadie cruce el recorrido de la
puerta del garage mientras se está cerrando.
ADVERTENCIA
ADVERTENCIA
ADVERTENCIA
ADVERTENCIA
ADVERTENCIAADVERTENCIA
SISTEMA DE
MONITOREO DE
LA PUERTA DEL GARAJE
PRUEBA DE PREINSTALACIÓN DEL SISTEMA
1. El sensor y el receptor se hacen corresponder (programados) de
fábrica. Pruebe el sistema invirtiendo el sensor mientras está a unos
pocos pies del receptor. El receptor muestra una luz verde cuando
está cerrado cuando el sensor está orientado hacia arriba en la
posición vertical con el de la caja apuntando haciaextremo redondo
arriba (Figura 1). La luz roja centellea cuando el sensor está orientado
hacia abajo en la posición horizontal (Figura 2).
2. Vea la sección de Localización de Fallas o de Aprendizaje de estas
instrucciones, si las luces verde o de receptor roja no se encienden, o
no reaccionan según se describe.
®
INSTALACION DE LA PILA EN EL SENSOR
INDICADOR DE LA PUERTA DEL
GARAJE
1. Coloque la hoja del destornillador la aleta alen
extremo de la caja y presione suavemente hacia
abajo y hacia adentro hacia la caja.
2. Inserte la pila de litio dentro del broche de la pila
con el lado + (positivo) hacia arriba.
3. Cierre bien la caja insertando los ganchos
superiores dentro de la cubierta posterior, a
continuación calce cerrada el fondo de la caja.
NOTA: Es normal escuchar un sonido metálico del
conmutador de inclinación en el sensor cuando está inclinado o girado a
otra posición.
PREPARACION DEL RECEPTOR INTERIOR
1. Enchufe el adaptador de CA dentro
de cualquier tomacorrientes
eléctrico de pared de 110 voltios de
CA y el enchufe pequeño dentro de
la parte inferior del receptor Interior.
2. El Receptor tiene un cable de
antena de 9" que sale de la parte
posterior. La antena debe estar
recta y no tocar el metal.
3
V O
LT
S
Figure 1 Figure 2
NOTA: A causa que los dispositivos de control por radio son
inherentemente susceptibles a la interferencia RF, este producto NO debe
usarse como un dispositivo de seguridad exclusivo. Este producto se
considera un dispositivo de monitoreo y notificación SOLAMENTE, y
como tal no debe usarse como un substituto para un sistema dedicado
de seguridad del hogar.
Deben efectuarse las inspecciones siguientes mensualmente, para
asegurar que el monitor de su puerta de garaje funcione apropiadamente:
• Inspeccione que el sensor esté montado apropiadamente en la puerta
del garaje (vea la sección de de este manual). Montaje del sensor
• Asegúrese que la pila de litio de 3 voltios esté instalada
apropiadamente.
• Inspeccione para verificar que el sistema receptor esté enchufado a un
tomacorrientes de pared y el jack esté conectado apropiadamente a la
parte posterior del receptor. Asegúrese que la antena esté recta y sin
contacto con objetos de metal.
• Verifique que el receptor reconozca apropiadamente las señales del
sensor (vea la sección de Localización de fallas de este manual.)
CL OS ED
OP EN
Antena Botón de
Aprendizaje
Ubicación del
Adaptador
de CA
Monitor de puerta de garaje
Model CLDM1
MONTAJE DEL SENSOR
Fije el sensor al interior de la puerta del garaje usando el tira sujetadora
de dos lados. Monte el sensor cerca del tope de la puerta del garaje para
obtener los mejores resultados. El de la caja debeextremo redondo
apuntar hacia abajo cuando la puerta del garaje está cerrada.
Interior Del Garaje
Tira Sujetadora de Dos Lados
Extremo Redondo
Orientado
Hacia Abajo
¡Sepa cuando la puerta del garaje está abierta
o cerrada!
Gracias por comprar el monitor de puerta de garaje Chamberlain. Vigile el
estado de la puerta de su garaje desde el interior de su casa. Nunca más
va a tener que bajar las escaleras o salir sólo para ver si sus niños han
dejado abierta la puerta del garaje.


Product specificaties

Merk: Chamberlain
Categorie: Niet gecategoriseerd
Model: CLDM1
Kastontwerp: Behuizing
Stroomverbruik: 50 mA
Maximum aantal deuren: 4 deur(en)
Ingebouwde UPS: Nee
Aantal codes: 254