Chamberlain 050ACTWFATSMC Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Chamberlain 050ACTWFATSMC (12 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 217 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/12
1
To insert or
remove the wires
from the terminal,
push in the tab with
a screwdriver tip.
Red
White
Grey
White
DANGER PELIGRO
132C2280-3D
TO ER ASE AL L
RECEIVER CODE S
1. Press and HOLD
receiv er ora nge
ERASE button
6 seco nds . Indicato r
light will tu rn ON.
2. Releas e bu tton
when lig ht turn s OFF .
CANADA:
PART NO.: NO. DE PIEZA:
DATE:
THE CHAMB ERLAI N
GRO UP, IN C., USA
Ensa mblad o en México
Ass emble d in Mex ico
ELIMINA CIÓN DE
TODOS LOS CÓDIGOS DE L
RECEPT OR
1. MANT ENGA PRESIONADO
el bo tón na ranja "ERASE"
del re ceptor dura nte 6
seg undo s. La luz de l
indicador se encenderá.
2. Suelte e l botón cuand o la
luz se apague.
DANGER PE LIGRO
132C2280-3D
TO ERASE A LL
RECEIVE R C ODE S
1. Press and H OLDreceiver orange
ERASE butto n
6 seconds. In d i cato r
ligh t wi ll tu rn ON .
2. Release butt o n when l ig h t t u rn s OFF .
CANADA:
P : PIEZ A:ARTN O. NO.DE
DATE:
THE CHAM BERLAIN GROU IN C.,U SAP,
Ensamblado en M éxi co
Assembled in M exi co
ELIMINA CIÓ N DE
TODOSLOS CÓDIGOS DEL
RECEPTOR
1. MANTENGAPRESIONADOel botón n aranj a "ERASE"
del recepto r d u ran te 6
segund o s. La lu z d el
indi cado r se en cend erá.
2. Suelte el b o tón cu an d o la
luz se apag u e.
Before you begin
1
Installation
RECEIVER LOGIC BOARD REPLACEMENT
Model 050ACTWFATS
1.2 To maintain your warranty, place the
provided label over the existing label
on the end panel of the door operator.
Place the STEP SAVER SETUP label on
the end panel directly below the yellow
LEARN button.
1.1 Remove the light lens by pulling the
top sides of the light lens and rotate the
light lens down. Squeeze the light lens
clips to remove lens from end panel.
Your new myQ® serial number is located on the replacement label with your replacement logic board. You will need this new myQ ® serial number to connect your operator to the network. You will also
have a STEP SAVER SETUP label that must be adhered to your end panel directly under the yellow LEARN button for future identification. This second label indicates your board has been updated, and a
new Product Label should be placed over the current Product Label. Your product may look different.
1.3 Disconnect power to the door operator.
Remove the receiver logic board
2
2.1 Disconnect the wires from the quick-connect terminals ( ). A
Remove the receiver logic board end panel from the door
operator.
2.2 Unplug the wire harnesses from the receiver logic
board. You may need needle-nosed pliers to remove
the harnesses.
To prevent possible SERIOUS INJURY or
DEATH:
• Disconnect ALL electric and battery
power BEFORE performing ANY service
or maintenance.
To prevent damage to the receiver/logic
board, DO NOT touch printed circuit board
of replacement receiver/logic board during
installation.
ALWAYS wear protective gloves and eye
protection when changing the battery or
working around the battery compartment.
2.3 Remove the receiver
logic board from the
end panel by removing
the 2 screws and
releasing the 2 clips.
Screws
Wire clip
Clips
WARNING: This product can expose you to chemicals including lead, which are known to the State of California to cause cancer or birth
defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
A
2
Rojo
Blanco
Gris
Blanco
Rouge
Blanc
Gris
Blanc
Red
White
White
Grey
Install new receiver logic board
3
3.3 Reinsert the wires.
Door control wires:
• white wire into the white terminal.
• white/red wire into the red terminal.
Safety sensor wires:
• white wires into the white terminal.
• white/black wires into the
grey terminal.
NOTE: A test of the safety reverse system is necessary for safe operation.
To insert or remove the
wires from the terminal,
push in the tab with a
screwdriver tip.
3.4 Install the light lens by aligning with
the hinges and snapping into place.
Reconnect power.
NOTE: When installing the light lens, ensure the
antenna wires are hanging straight down.
3.2 Insert the antenna wires through
the holes in the end panel. Snap the
receiver logic board into place on the
end panel and fasten with screws.
NOTE: Some
models will require
the short antenna
wire to be placed in
the traps of the end
panel.
Antenna wires
Antenna
wires
3.1 Connect the wire harnesses to the
new receiver logic board. When
reconnecting the wire harness, be sure
the tabs on the wire harness are facing
the end panel, not the logic board.
Tabs
Harness
End Panel
Wire Clip
Logic Board
Wire
NOTE: If your logic board
has a wire clip, use the
wire clip to hold wires to
the logic board.
DANGER PELI GRO
132C2280-3D
TO A L L ERASE
RECEIVER CODES
1.Pressand HOLD
receiverorange
ERASE button 6 seconds.Indicator
light will turnON.
2.Releasebutton whenli ghtturnsOFF .
CANADA:
P : PIEZA:ARTNO. NO. DE
DA:TE
THECHAMBERLAIN
GROUP, I NC., USA
Ensamblado Méxi co en Assembled M exi co in
ELIMINACIÓN D E
TODOSLOS CÓDIGOS DEL
RECEPTOR
1.MANTENG APRESIONADO
elbotónnaranja "ERASE"
delreceptordurante6 segundos.La del luz
indicadorseencenderá.
2.Suelteelbotóncuando la
luz apague. se
132C2280-3D
receiver orange
ERASE button
Assembled Mexico in
1. AMANTENGPRESIONADO
1
Programming
1.1 Press and release the Learn button on the door operator. The Learn indicator light will glow
steadily for 30 seconds.
1.2 Within 30 seconds, press and hold the
button on the remote control.
1.3 Release the button when the door
operator light blinks. It has learned the
code. If light bulbs are not installed, two
clicks will be heard.
Program a remote control using the learn button (not included)
Learn
Indicator
Light
Yellow Learn
Button
To program the Wi-Fi door operator to your network refer to your owner’s manual.
3
Program the travel
1
Without a properly installed safety reversal system,
persons (particularly small children) could be
SERIOUSLY INJURED or KILLED by a closing
garage door.
• Incorrect adjustment of garage door travel limits
will interfere with proper operation of safety
reversal system.
• After ANY adjustments are made, the safety
reversal system MUST be tested. Door MUST
reverse on contact with 1-1/2" (3.8 cm) high
object (or 2x4 laid flat) on floor
While programming the travel, the UP and DOWN
buttons can be used to move the door as needed.
The Safety Reversing Sensors will be disconnected
during the Program the Travel process. During the
Automatic Force Setup the door will automatically
open and close.
1.1 Press and hold the Adjustment Button
until the UP Button begins to and/î™­ash
or a beep is heard.
The Safety Reversing Sensors will be
disconnected during the Program Travel the
process.
1.2 Press and hold the UP until the Button
door is in desired UP position.the
1.3 Once the door is in the desired
UP position press and release the
Adjustment door Button. The garage
opener lights will flash twice the and
DOWN Button will begin to î™­ash.
1.4 Press and hold the button DOWN
until the is in the desired door DOWN
position.
Once both the up and down positions have been manually set, the Safety Reversing Sensors
will reconnect and become operational. Then, the opener will enter a force-sensing operation by
automatically moving the door open and close. The garage door opener will sound an audible and
visual alert before automatically opening and closing the door. The garage door opener will beep
three times, conrming that the Automatic Force Setup completed successfully. Adjustment is
complete.
If you hear one long beep after the door attempts to move, then the Automatic Force Set Up has
not completed successfully. Please start over at step 1 of Program the Travel..
Adjustment
Automatic Force Set Up
2
1.5 Once the door is in the desired DOWN
position press and release the Adjustment
Button. The garage door opener lights will flash
twice. Program the Travel is now complete. If
the garage door opener lights flash 5 times,
then programming has timed out and the Travel
Limits have not been set. Please restart the
Program the Travel process.
1.6 Add the Step Saver sticker under the yellow
program button.


Product specificaties

Merk: Chamberlain
Categorie: Niet gecategoriseerd
Model: 050ACTWFATSMC

Heb je hulp nodig?

Als je hulp nodig hebt met Chamberlain 050ACTWFATSMC stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Chamberlain

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd