ATTENTION ELECTRICIANS:
ANY PROBLEMS FOUND DURING INSTALLATION OF THE FAN PLEASE CONTACT THE NATIONAL
WARRANTY NUMBER PRIOR TO LEAVING SITE.
DO NOT REMOVE THE FAN FROM THE CEILING
UNLESS INSTRUCTED TO DO SO.
National Warranty Number | 1300 116 305 Monday to Friday 9am to 5pm AEST
NOTE: THIS FAN MUST BE INSTALLED BY A LICENSED AND QUALIFIED
ELECTRICIAN IN ACCORDANCE WITH LOCAL AUTHORITY REGULATIONS
Australian Edition Version 1. 0 August 2019
Four Blade 48”or 52”Four Blade 48”or 52”
without light
with light
NOTE: THIS FAN MUST BE INSTALLED BY A LICENSED AND QUALIFIED
ELECTRICIAN IN ACCORDANCE WITH LOCAL AUTHORITY REGULATIONS
1
IMPORTANT INFORMATION - PLEASE READ BEFORE ATTEMPTING INSTALLATION
1. Please read these instructions carefully, shown be mindful of all warnings safety information and throughout this
manual. Should you have any questions please call .1300 116 305
2. Please review the accompanying assembly diagrams before attempting installation.
3. This fan MUST installed by according authority regulations inbe a & qualified licensed electrician to local and
accordance with current wiring rules AS/NZS3000.
4. A copy purchasing receipt proof of the and of installation by a licensed and qualified electrician to according local
authority regulations is required for all warranty claims.
5. Where special access equipment is required accordance with authority regulations all associated costs arein local
the responsibility of the owner.
6. We reserve the right to charge fee for all call outs where the fan found to be defective a $175 service is not
and / or where access is not provided.
7. The fan and light (if supplied) MUST be earthed.
8. Do not mix blades between fans. The blades are provided as a complete matching set.
9. The fan to function the wall controller provided the box. Your warranty will be void if anyis designed only using in
non approved (by ) wall controllers or remote units are used with the fan.EM Imports
10. The means for incorporated fixed accordance with nationalmains power disconnection must be in the wiring in
wiring rules.
11. It is responsibility owner to have electrician check the installation fan if any unexpectedthe of the their of the
noises are found.
12. Installations ceilings using steel beams, grid and flexible structures are not recommended inability todue to their
absorb vibration caused through the normal operation. Timber is the recommended to mount the fan.
13. To avoid possible electric shock during installation, be sure electricity is turned off at the main power box before
commencing work. Disconnect power by removing fuse or turning off circuit breaker before installing the fan.
Ensure all spliced connections are adequately insulated.
14. Warning! allow the rotating fan come into contact with any cause seriousDo not blades to object, this can
injury or death.
15. Damage caused by; incorrect installation, force-majeure, lightning, electrical surges & spikes, exposure to water,
pests or moisture is not covered under warranty.
16. In accordance with AS/NZS60355-1 & ASNZS60355-2-80: not intended for use by persons“This appliance is
(including children) with reduced physical, or mental capabilities, or lack of experience knowledge,sensory and
unless they a have been given or instruction use of the appliance by supervision concerning person responsible
for their safety.”
17. Children should be supervised to ensure that they do not play with the appliance.
18. Children shall not play with the appliance.
19. Cleaning and user maintenance shall not be made by children without supervision.
Please Note: Nothing in this manual is intended to instruct or assist untrained or
unqualiîšżed persons to install this product. Additionally, it is the responsibility of the
installer and user to apply common sense and care at all times.
Please note: Minor design changes may result in slight variations between the product illustrations and the fan contained within the packaging.
National Warranty Hotline|1300 116 305 Monday to Friday 9am to 5pm AEST
2
LOCATION AND INSTALLATION REQUIREMENTS
Provide clearance from floor fan adequate the . The lowest point on the
blades must be at least 2.1m (7 feet) from floor level in Australia.
Make sure that the chosen location of the fan will allow the rotating not
fan blades to come into contact with any objects.
Ensure ceiling joists are sound of adequate size and strength to and
support a 25Kg (55lb) load.
To reduce fire, injurythe risk of electrical shock or personal , ensure
that the fan bracket is directly from the building mounting supported
structure. After the fan installed, check to make sure that is completely
all connections are secure to prevent the fan from falling and/or causing
damage or injury.
To reduce the risk of personal injury, do not bend or damage the motor or
Fan Assembly when handling or during installation. Please ensure special care is taken when assembling the fan. Each
screw must be sufîšżciently tightened.
minimum
2100mm
Floor Level
FAN ASSEMBLY
Secure the hanger bracket to ceiling beam or a suitable piece of timber inserted between the ceiling beams. Install the
mounting bracket using two (2) long screws as supplied within the package.
In accordance with Australian Standards, the fan blades must be at least 2.1 metres above oor level and
the blades require at least 300mm clearance to the nearest object.
Support Rod
Hanger Ball
Ball Joint Slot
Mounting Bracket
Place fan into hanger bracket and align ball joint slot with hanger bracket as illustrated below.