BUSHMAN DC230-X
230L 12V / 24V DC Upright Fridge
Congratulations on your purchase of DC230 a Bushman -X. Please read these instructions carefully
before installation and use.
IMPORTANT INFORMATION
Do not lay your fridge on its back, top or sides or at any angle exceeding 30º. If your fridge has been handled
this way, stand the fridge upright for 12 hrs to allow the internal fluids to redistribute evenly before use.
Never operate your fridge directly from a 240 V or AC power . supply
Do not use a modified sine wave inverter to operate your fridge.
PRIOR TO INSTALLATION
DELIVERY
At delivery, please check that the fridge is complete and is not damaged in any way. Remove all packaging and
securing tapes from the fridge. To avoid injury and causing damage to the appliance, be extremely cautious
when using sharp or pointed tools to complete this task. Do not connect an appliance that has been damaged,
contact Bushman immediately.
INSTALLATION
2
Installation of the DC230-X must be completed by a suitably trained professional only.
POWER SUPPLY
Your fridge V V must be connected to a stable and regulated 12 or 24 DC power supply only. The compressor
will automatically detect which voltage is present and adjust accordingly.
If you are using a generator or other power supply, the output must be only a pure sine wave.
WIRING
Always wire your fridge directly to your battery terminals. Do not run the wires via a buss bar, battery
management system or shared circuit. Please also ensure the earth is wired directly to your battery, not to a
chassis.
Ensure the wiring polarity is correct. Connect the red wire to the positive terminal (+) and the black wire to the
negative terminal (-). Never connect bare electric wires. Use only connections of a size suitable for the cross
section of the wire being used.
CROSS
SECTION
IN MM2
AWG
(AMERICAN
WIRE GAUGE)
MAXIMUM LENGTH OF WIRE IN
METRES
12 V
24 V
2.5
14
2.5
5
4
12
4
8
6
10
6
12
10
8
10
20
ISOLATION SWITCH AND FUSE
We recommend installing an isolation switch for the fridge circuit as close to your battery bank as possible. Any
switches must have a breaking load not less than 20 A on 12 V or 10 A on 24 V.
The power supply wiring must also be protected with a 15 A fuse.
INSTALLATION IN A CAVITY
Your new fridge 5is designed to be installed in a cavity. We recommend allowing a minimum mm gap on each
side and the top for ease of installation. A minimum gap of 25mm is required for the rear. Refer to the following
table for the recommended - cut out dimensions.
MODEL
WIDTH
DEPTH
HEIGHT
DC230-X
605
550
1460
MOUNTING KIT
Position the mounting kit flush with the front edge of the fridge cabinet and mark the position of the holes. Drill
shallow, to the side and top of 3mm drill bit, pilot holes through the sheet metal cabinet. Affix the mounting kit
the fridge cabinet using the screws provided.
Once the fridge has been connected to the power supply and moved into its final position, the mounting kit can
be affixed to the front of the cavity.
INTERNAL MOUNTING SLEEVES
There are 4 internal mounting sleeves on internal mounting sleevethe inside 2 of the fridge cabinet, and s in the
inside of the freezer compartment. Access is provided by gently levering off the plastic caps. M5 screws or
bolts need to be used. Drill 4mm pilot holes through the plastic sleeve and right through the fridge cabinet
sides. Put a small nylon washer onto the screw / bolt heads before inserting. Ensure that the exterior of the
fridge cabinet is flush with your cabinetwork before affixing the screws / bolts. If there is a gap, pack it out with
a suitable hard material. C heck for screw / bolt tightness after your first trip.
VENTILATION
3
V entilation will have a critical impact on the efficient operation of your fridge. A minimum of 2 vents needs to be
provided from the rear of the fridge cavity to the outside environment, or to the main room where the fridge is
located. The vents should be located at the bottom and top of the fridge cavity and have a free cross section of
minimum 600 00mm x 2 0mm vent will have only a free cross section of approximately cm2 each. Note that a 5 5
6 00 cm2 (not 1250 cm2).
OPERATING THE FRIDGE
THERMOSTAT
• The cooling level can be set between 1 and 7 7 is the coldest setting and 1 is the warmest. ( )
• The most comon setting is between 3 and 5.
• Use the lowest settig possible.
• Avoid using setting 7 as this will cause considerbale ice build up in the firdge.
EQUALISING THE FRIDGE
During the first 24 hours of operation, your compressor will operate for longer than usual. This process allows
the internal air temperature, food, drinks, condenser, compressor, and insulation to equalise.
KEEP HOT / WET ITEMS OUT OF THE FRIDGE
Try and - keep hot or wet items out of the fridge as they are a prime source of moisture and ice build up.
SPACE ITEMS, ESPECIALLY ON THE TOP SHELF
It’s important to keep some space between your items in the fridge so that the cold air can circulate. This is
critically important on the top shelf so the cold air from the cooling element can fall into the fridge cabinet.
Round items like cans and jars are good for the top shelf as they allow space around them. Packets of meat etc
are probably the worst items as they create an insulated barrier between the top shelf and the rest of the fridge.
RUBBER SEALS ARE CLEAN
Keep your rubber seals clean and free from stickiness. You can clean the rubber seals and the front edge of
the fridge cabinet with warm, soapy water.
HAVE GOODS INSIDE THE FRIDGE
The fridge will not operate properly if it is empty, as air does not hold temperature well. If you are using a
wireless thermometer the temperature readout will fluctuate significantly with the changes in air temperature,
whilst your drinks inside the fridge will not vary much at all.
DEFROSTING
Defrosting needs to be carried out when the ice layer reaches a thickness of 5 - 10mm.
Turn off the power to the fridge and move your food and beverages to another cool place. Do not use any
objects to remove the ice or frost, it must be allowed to melt naturally. Once the ice has melted, thoroughly dry
the inside of the fridge and freezer compartment. Re- start the fridge on setting 4 and monitor after 24 hours.
CLEANING
Wash the inside of your fridge with lukewarm water and a mild soap. Never use abrasive or corrosive cleaning
agents, steel wool or scrapers of any kind, scouring sponges . A soft sponge, towel, or soft brush is
recommended.
Keep the doors of the fridge ajar when the fridge is not in use esh air to circulate inside the fridge , to allow fr
compartment.