BroilKing Porta-Chef 120 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor BroilKing Porta-Chef 120 (24 pagina's) in de categorie Barbeque / Contactgrill. Deze handleiding was nuttig voor 17 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/24
GAS BARBECUES
OWNER'S MANUAL
FOR USE WITH L.P. GAS (LIQUIFIED PETROLEUM GAS)
IN CANADA - PROPANE GAS
DANGER
If you smell gas:
1. Shut off gas to the appliance.
2. Extinguish any open flame.
3. Open lid.
4. If odor continues, keep away from the
appliance and immediately call your gas
supplier or your fire department.
WARNING
1. Do not store or use gasoline or other
flammable liquids or vapors in the vicinity
of this or any other appliance.
2. An LP cylinder not connected for use shall
not be stored in the vicinity of this or any
other appliance.
ANSI Z21.58b-2012 / CSA 1.6b-2012
CONTENTS
SAFETY .............................................................2
INSTALLATION .................................................2
L.P. GAS CYLINDER.........................................3
OPD EQUIPPED CYLINDER.............................4
HOSE & REGULATOR......................................4
LEAK TESTING .................................................5
VENTURI TUBES ..............................................5
LIGHTING ..........................................................6
OPERATION ......................................................7
COOKING TECHNIQUES..................................7
MAINTENANCE...............................................10
TROUBLE SHOOTING....................................11
WARRANTY ....................................................12
Please record your model and
serial number here.
Model number
Serial number
Date of purchase
READ ALL INSTRUCTIONS CAREFULLY BEFORE OPERATING YOUR GAS BARBECUE
RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE
1-800-265-2150
info@omcbbq.com
10094-LP REV L 04/13
SAFETY INSTALLATION
Your new OMC gas grill is a safe, convenient appliance
when assembled and used properly. However, as with all
gas-fired products, certain safeguards must be observed.
Failure to follow these safeguards may result in
damage or injury. If you have questions concerning
assembly or operation, consult your dealer, gas appliance
serviceman, your gas company or our direct customer
service line at 800-265-2150.
CAUTION
FOR OUTDOOR USE ONLY.
IF STORED INDOORS, DETACH AND LEAVE
CYLINDER OUTDOORS.
THIS APPLIANCE MUST NOT BE OPERATED
UNATTENDED.
SPECIAL CARE MUST BE TAKEN TO KEEP
SMALL CHILDREN AWAY FROM HEATED
SURFACES.
2
Use caution when handling or transporting this
product. Metal edges can present a hazard. Use
appropriate gloves when lifting or handling. Before
lifting, remove side shelves and grids and grates.
ELECTRICAL CAUTION
1. If any accessory is used on this appliance that
requires an external electrical power source, the
accessory when installed must be electrically
grounded in accordance with local codes. In the
absence of local codes, the following standards apply:
(U.S.A.) ANSI/NFPA No. 70-Latest Edition
and
(CANADA) CSA C22.1 Canadian Electrical Code
2. Do not cut or remove the grounding prong from the
plug.
3. Keep the electrical supply cord and fuel supply hose
away from any heated surface.
PROPOSITION 65 WARNING
Handling the brass material on this product exposes you to
lead, a chemical known to the state of California to cause
cancer, birth defects or other reproductive harm. WASH
YOUR HANDS AFTER HANDLING THIS PRODUCT.
WARNING
Fuels used in gas or oil-fired appliances, and the products
of combustion of such fuels, contain chemicals known to
the State of California to cause cancer, birth defects or
other reproductive harm.
“This warning is issued pursuant to California Health and
Safety Code Sec. 25249.6”
1. In Canada, this appliance must be installed in
accordance with the local code and the relevant
CSA standards:
CSA-B149.1 Natural Gas and Propane installation Code
In the U.S.A., this appliance must be installed in
accordance with the local code and the relevant
national code.
ANSI Z223.1/NFPA 54 - Latest Edition National Fuel Gas
Code and Latest Local Codes where Applicable
2. The appliance must be located away from combustible
surfaces by at least 76cm/30” from each side, and
76cm/30” from the rear.
76cm / 30”
76cm / 30”
3. Do not operate this appliance under any overhead
roof construction or foliage.
4. This appliance is for OUTDOOR USE ONLY, DO NOT
operate in garage, shed, balcony or other such
enclosed areas.
5. DO NOT restrict the flow of air to the appliance.
6. Keep the area surrounding the appliance free of
combustible materials, gasoline, and all flammable
liquids and vapours.
7. This appliance is not intended to be installed in, or on,
recreational vehicles and/or boats.
8. Keep the ventilation opening(s) of the cylinder
enclosure free and clear from debris.
LP GAS CYLINDER PLACEMENT
9. LP gas cylinders must be installed according to
assembly instructions using retainer provided. Do not
store a spare cylinder under or near this appliance. All
cylinders used must be compatible with supplied
means of cylinder retention.
3
LP GAS CYLINDER
QCC
®
-1 QUICK CLOSING COUPLING
All models are designed to be used with an LP gas
cylinder equipped with the QCC
®
-1 Quick Closing
Coupling system.
The QCC
®
-1 system incorporates new safety features
required by the American National Standards Institute
(ANSI) and the Canadian Standards Steering Committee.
Gas will not flow until a positive connection has been
made.
A thermal element will shut off the flow of gas between
240° and 300° F.
When activated, a Flow Limiting Device will limit the
flow of gas to 10 cubic feet per hour.
NIPPLE WITH FLOW SHUT OFF
LIMITING DEVICE VALVE
HEAT SENSITIVE CYLINDER
HAND WHEEL
REGULATOR
CHECK VALVE
The LP Gas Cylinder is not included with the Gas Grill.
Be sure to purchase one with the QCC
®
valve. This valve
is recognized by the external threads on the inlet port of
the valve. QCC
®
equipped cylinders are available from
your Gas Grill Dealer.
Any attempt to connect the regulator, by use of
adapters or any other means, to any other valve could
result in damage, fire or injury and may negate the
important safety features designed into the QCC
®
-1
system.
SPECIFICATION:
1. All LP gas cylinders used with this appliance must be
constructed and marked in accordance with the
Specifications for LP Gas Cylinders of the U.S.
Department of Transportation (D.O.T.) or the National
Standard of Canada, CAN/CSA-B339, Cylinders,
Spheres and Tubes for Transportation of Dangerous
Goods; and Commission, as applicable
2. The LP gas cylinder used for this appliance must not
have a capacity larger than 20 lb.(9 kg).
Approximately 18" (46cm) high
12" (31cm) diameter
3. All LP gas cylinders used with this appliance should be
inspected at every filling and re qualified by a licensed
service outlet at the expiry date (10 years), in
accordance with the DOT (USA) and CTC (Canada)
codes for LP Gas Cylinders.
4. All LP gas cylinders used with this appliance must be
provided with a shutoff valve terminating in a cylinder
valve outlet No. 510, specified in the Standard for
Compressed Gas Cylinder Valve Outlet and Inlet
Connection (USA) ANSI/CGA-V-1-1977 (Canada)
CSA B96.
The cylinder supply system must be arranged for
vapor withdrawal.
The cylinder must include a collar to protect the
cylinder valve.
The cylinder must be installed as per assembly
instructions.
Never fill the cylinder beyond 80% full. A fire causing
death or serious injury may occur.
The cylinder valve must include a safety relief device
having direct communication with the vapour space of
the cylinder.
HANDLING:
1. Government regulations prohibit shipping full LP gas
cylinders. You must take your new cylinder to a LP
gas dealer for filling.
2. A filled LP gas cylinder is under very high pressure.
Always handle carefully and transport in the upright
position. Protect the valve from accidental damage.
3. Do not tip the LP gas cylinder while connecting it to the
regulator. Fasten the cylinder securely during
transport, use and storage.
4. If the cylinder is tipped after it is connected to the
regulator, shut off the gas, disconnect the regulator
and have it checked before using again.
STORAGE:
1. Store the LP gas cylinder outdoors in a well ventilated
place.
2. Do not store the LP gas cylinder in direct sunlight, near
a source of heat or combustion.
3. If you intend to store the grill indoors, disconnect and
remove the LP gas cylinder first. Disconnected
cylinders must have a dust cap installed and must not
be stored in a building, garage or any other enclosed
area.
4. Keep out of the reach of children.
5. When the LP gas cylinder is connected to the gas grill,
the gas grill and LP gas cylinder must be stored
outside in a well ventilated place.
OPERATION:
1. Never connect your gas grill to an LP gas cylinder
without the regulator provided, and NEVER TO AN
UNREGULATED LP GAS SUPPLY. The gas
regulator supplied with the appliance must be used.
2. Always leak test the LP gas cylinder to regulator
connection when connecting the LP gas cylinder to the
appliance. See "Leak Testing".
3. Do not operate appliance if the smell of LP gas is
present. Extinguish all flame and determine source of
LP gas before proceeding. Do not ignite the
appliance until the LP gas leak has been found and
sealed.
4. Always shut off LP gas cylinder valve when the
appliance is not in use.


Product specificaties

Merk: BroilKing
Categorie: Barbeque / Contactgrill
Model: Porta-Chef 120

Heb je hulp nodig?

Als je hulp nodig hebt met BroilKing Porta-Chef 120 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Barbeque / Contactgrill BroilKing

Handleiding Barbeque / Contactgrill

Nieuwste handleidingen voor Barbeque / Contactgrill