BlueDri ONE 33 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor BlueDri ONE 33 (2 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 42 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/2
3-SPEED
CENTRIFUGAL
AIR MOVER
Owners Manual
Read and save these instructions.
bluedri.com
Owner’s Manual | ONE33
Unit Assembly
Wear items exempt from warranty consideration include but may
not be limited to: power cords, transport wheels, castors, handle
grips, filters, screens, brushes and carbon brushes. Subject to the
conditions and exceptions stated in this warranty, warrants BlueDri
the BlueDri products to be free from defects in material and
workmanship, under normal use and service, for the periods listed
under the warranty policy to the original purchaser. At any time during
the warranty period, BlueDri will furnish replacement parts for the
BlueDri products to the original purchaser. Such parts will be furnished
and charged including transportation costs, original owner. If the
original part is returned within the warranty policy period from date of
delivery for inspection by and is found to be defective, the BlueDri
owner will be credited for the cost of replacement parts plus shipping
and handling. Replacement parts that have become defective through
wear or abuse are not included in this warranty .This warranty does not
apply to damage or defect caused by accident, misuse, negligence, re
or to any product which has been serviced or repaired by other BlueDri
than an authorized Service Distributor or BlueDri BlueDri factory
personnel. This warranty is void if products are used for any purpose
other than that which was intended. There are no other warranties
expressed or implied. In no event shall BlueDri be liable for incidental
or consequential damages or any damage to person or property.
(Please note some states do not allow the exclusion or limitations for
incidental and consequential damages.)
Limied Warranty
1-Year Coverage
Subject to the conditions stated below, BlueDri oers a limited
warranty on parts and labor on the following equipment, parts and
accessories to be free from defects in material and workmanship for
a period of one year to the original purchaser.
5-Year Coverage
Subject to the conditions stated below, BlueDri warrants parts
and labor on rotationally molded polyethylene tanks/housings and
injection molded vacuum head assemblies to be free from defects
in materials and workmanship for a period of ten years to the
original purchaser.
Unit Specications
Certifications C-ETL-US
Motor Rating 0.33 HP
Power 115 V, 60 Hz
Current 2.0/2.5/3.3 amps
Weight 28 Lbs
Dimensions 17.3”W x 16”L x 18”H
Power Cord Length 25
Speeds 3
Specifications are subject to change without notice.
Operation
Plug your air mover into a standard grounded outlet with the correct voltage
and amperage. If you are unsure about the outlet, contact your supervisor. Turn
on the switch and check that the unit operates properly before letting it run
A 45 degree angle is good for drying furniture after a cleaning.
A 90 degree angle is ideal for walls and ceilings.
12
3
4
5
6
78
9
10
11
12
13
14
15
16
Item Desciption QTY
1 Inlet Grill 1
2 Plastic Cover 1
3 Fan wheel 1
4 Fan Housing 1
5 Motor 1
6 Inlet Grill 1
7 Connector 1
8 Power Cord 1
9 Circuit Breaker 1
10 Switch Box 1
11 GFCI 1
12 Switch 1
13 Switch Label 1
14 Switch Knob 1
Flat 45 Degrees 90 Degrees
Owner’s Manual BlueDri® ONE | 33 bluedri.com
GFCI Protection and the On-Board Duplex Outlet:
The standard AC voltage outlet GFCI (Ground Fault Circuit Interrupter) promotes operator safety in wet applications. GFCI devices trip when
a fault to electrical ground is sensed. It is recommended to check the GFCI protection prior to operation. To check, push the "TEST" button
located on the GFCI duplex outlet will pop out. If operating properly the "RESET" button on the GFCI outlet will pop out. Depending on your
Centrifugal Air Movers specific equipment, a tripped GFCI may be indicated by a small LED. The device can only be "RESET" when the
Centrifugal Air Mover is connected to a wall outlet providing standard voltage. This duplex AC outlet allows the inter-connection of other AC
powered devices. The sum total amperage of all devices (excluding therst fan) plugged into the receptacle must not exceed 8.7 amps.
Problem
Unit will not run
Possible Cause/Solution
•No power to unit-Plug it in. Check circuit breaker
•Switch not on-Place in “ONposition.
•Switch is faulty-Replace switch.
•Faulty/broken cord or motor wire-Perform continuity check, using volt/amp meter.
Repair/replace faulty broken wire.
Unit runs but air mover makes loud
scraping noise
•Unit has been severely jolted causing blower wheel to rub against housing-Remove motor
and replace damaged motor mounts.
•Unit has been severely jolted causing housing to deform-Replace blower wheel.
Unit runs but vibrates excessively •Severe jolt has bent motor shaft causing unit to be out of balance-Remove and replace motor.
•Air mover blade damaged-Replace blade if necessary.
•Dirt build up on one side of air mover blade-Clean air mover blade.
Unit runs but blower wheel does not turn
•Motor bearings are falling or motor has developed an internal electrical fault-Replace motor.
•Intake grill and/or exhaust grill is obstructed-Replace blade if necessary.
•Excessive duct length-Reduce duct length to recommended maximum.
Troubleshooting


Product specificaties

Merk: BlueDri
Categorie: Niet gecategoriseerd
Model: ONE 33

Heb je hulp nodig?

Als je hulp nodig hebt met BlueDri ONE 33 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd BlueDri

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd