Berner SHD07-1036AA Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Berner SHD07-1036AA (12 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 61 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/12
Thank you for choosing Berner.
Berner International has been saving energy and creating healthy, comfortable environments for our customers for over 60 years.
Berner oers unmatched quality, performance, and dependability—not to mention our service. At Berner, we stand behind our products.
TABLE OF CONTENTS
I. UNCRATING............................................................................................................................................................ 2 ........................................................
II. GENERAL MOUNTING INSTRUCTIONS ................................................................................................................................. 4 ...................................
III. WALL MOUNTING ...................................................................................................................................................................................................... 5
IV. SUSPENDED MOUNTING ....................................................................................................................................... 6 ...................................................
V. ELECTRICAL CONNECTIONS 7 .....................................................................................................................................................................................
VI. FIELD CONNECTIONS 7 ................................................................................................................................................................................................
VII. OPERATING INSTRUCTIONS 8 ....................................................................................................................................................................................
VIII. MAINTENANCE AND CLEANING 9 ............................................................................................................................................................................
IX. SERVICE ............................................................................................................................................................... 9 ........................................................
X. TROUBLESHOOTING ................................................................................................................................................................................................. 10
XI.WARRANTY ................................................................................................................................................ 12 ................................................................
Installation & Maintenance Instructions
Commercial High Performance 10
Air Curtain Series #CHD10
Sanitation Certied High Performance 7
Air Curtain Series #SHD07
www.Berner.com
II-123D
June, 2020
©Copyright, 2020 Berner International
READ ALL INSTRUCTIONS BEFORE INSTALLING OR USING AIR CURTAIN
ANSI/NSF 37
Air Curtain Fans
for Customer Entry
12CS
for outdoor use
SHD07 SHD07 SHD07
®
When the door is open, BERNER AIR CURTAINS
2
Carefully examine the carton(s) for damage. If the carton is
damaged, immediately notify the shipping company. Do not
delay in ling claim. If the air curtain(s) were shipped on
wooden skids, remove protective wood and banding straps
securing the carton(s) to the skid. Open the carton(s) and
remove all protective packaging.
Immediately verify that the electrical rating nameplate located
on the cover matches electrical power supply available. Retain
the shipping carton(s) until the air curtain(s) are installed and
properly operating.
ACCESSORIES:
If the air curtain was ordered with a wall mounting plate,
remove and save the two (2) locking screws from the back
corners and detach the wall mounting plate. See Figure 1.
If the air curtain(s) were ordered with optional electrical acces-
sories, the accessories will be found in the carton containing
the air curtain or in a separate carton(s) accompanying the air
curtain(s). Check all of the cartons/skids for accessories before
discarding.
A. Read all instructions before installing or using this air curtain.
B. Use this unit only in the manner intended by the manufacturer and described in this manual. Any other use not recommended by the
manufacturer may cause re, electric shock, or injury to persons. If you have any questions, contact the manufacturer.
C. Before servicing or cleaning unit, switch power o at service panel and lock the service disconnecting means to prevent power from
being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device,
such as a tag, to the service panel.
D. Installation work and electrical wiring must be done by qualied person(s) in accordance with all applicable national and local codes
having jurisdiction, including re-rated construction. See page 7, ELECTRICAL CONNECTIONS (NEC Code ANSI/NFPA No. 70).
E. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
F. To reduce the risk of re, do not store or use gasoline or other ammable vapors and liquids in the vicinity of the air curtain.
G. This air curtain is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. Keep combustible materials, such as furniture,
pillows, bedding, papers, clothes, etc. and curtains at least 1 inch from the top, back, front, sides and at least 6 feet from the discharge
of the air curtain.
H. Extreme caution is necessary when any air curtain is used by or near children or invalids, and whenever the heater is left operating
unattended.
I. Do not operate any air curtain after it malfunctions. Disconnect power at the service panel and have the air curtain inspected by a
reputable electrician before reusing.
J. To disconnect the air curtain, turn controls to "o", and turn o power to the air curtain circuit at main disconnect panel.
K. Do not insert or allow foreign objects to enter any ventilation or discharge opening as this may cause an electric shock or re, or
damage the air curtain.
L. To prevent a possible re, do not block the air intake or discharge of the air curtain in any manner.
M. The air curtain has hot and arcing or sparking parts inside. Do not use it in areas where gasoline, paint, or ammable vapors or liquids
are used or stored.
N. This heater may include an audible or visual alarm to warn that parts of the heater are getting excessively hot. If the alarm sounds
(or illuminates), immediately turn the heater o and inspect for any objects on or adjacent to the heater that may have blocked the airow
or otherwise caused high temperatures to have occurred. DO NOT OPERATE THE HEATER WITH THE ALARM SOUNDING (OR ILLUMINATING).
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
I. UNCRATING
Commercial High
Performance 10
Air Curtain
(Air Door)
Sanitation Certied
High Performance 7
Air Curtain
(Air Door)
3
Berner International
111 Progress Ave. / New Castle / PA / 16101 / USA
To use threaded
rod to hang from
the ceiling
instead of
the wall - use
the fa ory ct
installed
threaded inserts.
12
34
To wire – follow the wiring diagram (found inside
wiring compartment).
The controls ship in the same box as the air curtain.
56
For more information see page 4 For more information see page 4
For more information see page 5 For more information see page 5
For more information see page 6 For more information see page 7
Before hanging,
check to see what
the clearance is
above the door.
A
I
R
A
I
R
Rule of thumb – If the unit must be mounted
higher than 1” above the opening, it must be
spaced out from the wall 3/8 for every inch the
unit is above the door opening.
Simple to Install
Easy to operate & maintain
6' minimum*
20˚
4" minimum*
AIR
Discharge
Nozzle
4" minimum
side clearance
from
combustible
material*
*Electrically Heated Units Only
INTERIOR
EXTERIOR
Flush Mounting
1"
AIR
CURTAIN
Top of Door ywa
2" 3"
AIR
CURTAIN
Spacer
Spacer
Seal
3/8"
3/4"
Mark the wall according to
the length of the air curtain.
If the keyhole slots are not
located where suitable
suppor t is available,
drill new holes in
the back plate
where space
is available.
After installing the mounting hardware, lift and
slip the air curtain over the mounting hardware by
grasping the inlet rings. Tighten the mounting
hardware.
The keyhole slots are spaced 1 from
the ends, and 3/4” and 7” from the top.
Line-up
Keyholes on
All Screws
Push
Backplate
Toward Wall
Slide
Backplate
Down
Tighten All
Screws
1/4"
Suspension Rods
1/4” Threaded Insert
Side View
Keyhole
Mounting
Slots
7"
3/4"
1"
®


Product specificaties

Merk: Berner
Categorie: Niet gecategoriseerd
Model: SHD07-1036AA

Heb je hulp nodig?

Als je hulp nodig hebt met Berner SHD07-1036AA stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Berner

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd

Smeg

Smeg GTA-6 Handleiding

21 November 2024
Smeg

Smeg KIT6CX Handleiding

21 November 2024
Senal

Senal SCS-98 Handleiding

21 November 2024
Senal

Senal ASM-6 Handleiding

21 November 2024
Senal

Senal ASM-MNTKIT Handleiding

21 November 2024
Senal

Senal SMS-45 Handleiding

21 November 2024
Smeg

Smeg KIT6PX Handleiding

21 November 2024
Senal

Senal SCI-3212MP Handleiding

21 November 2024
Senal

Senal OLM-2S-P Handleiding

21 November 2024