Please keep these Instructions safe.
Should you move house, please hand
them over to the next occupier.
Baxi Solo 2 RS Range
Wall Mounted Room Sealed
Gas Fired Central Heating Boilers
User’s Operating
Instructions
1
2
3
Your Baxi Solo is a gas fired, room sealed central heating boiler providing
heating for your home and domestic hot water where required.
OPERATING YOUR SOLO
Remove lower door panel as
shown.
Turn the boiler thermostat knob
to the '0' position fully anti-
clockwise.
Turn on the main gas and
electricity supplies to the
appliance.
To light the pilot: Looking
through the pilot viewing window
press the gas control knob fully
inwards and hold. Press in igniter
button and release. Repeat until
pilot ignites. Continue to hold in
gas control knob for
approximately 15 seconds
and then release. Pilot should
stay alight.
NOTE: If pilot fails to remain alight or
is extinguished at any time, wait at
least 3 minutes then repeat the
procedure from the start of section "4".
Once the pilot is alight it may be left
on permanently.
To light the boiler: Ensure that
all external controls, e.g. room
thermostat, timer, etc. are calling for
heat. Turn boiler thermostat fully
clockwise to high setting. Main burner
will then light.
It is recommended that the boiler
thermostat is used on HIGH setting
in winter and a minimum of n
o2 in
summer to ensure adequate
domestic hot water.
BOILER THERMOSTAT KNOB
1
2
3
4
5
IGNITER BUTTON
GAS CONTROL
KNOB
Natural Gas
Baxi Solo 2 60 RS
G.C.No. 41 077 79
Baxi Solo 2 50 RS
G.C.No. 41 077 78
Baxi Solo 2 40 RS
G.C.No. 41 077 77
Baxi Solo 2 30 RS
G.C.No. 41 077 76
Baxi Limited is one of the leading
manufacturers of domestic heating products in
the UK.
Our first priority is to give a high quality service
to our customers. Quality is built into every
Baxi product - products which fulfil the
demands and needs of customers, offering
choice, efficiency and reliability.
To keep ahead of changing trends, we have
made a commitment to develop new ideas
using the latest technology - with the aim of
continuing to make the products that
customers want to buy.
Everyone who works at Baxi has a
commitment to quality because we know that
satisfied customers mean continued success.
We hope you get a satisfactory service from
Baxi. If not, please let us know.
Baxi is a BS-EN ISO 9001
Accredited Company
β€œ ”Benchmark Installation, Commissioning and
Service Record Log Book
Please ensure that your Installer has completed
the Installation and Commissioning sections of
the Log Book, and hands the Log Book over. The
details of the Log Book will be required in the
event of any warranty work. Keep the Log Book in
a safe place and ensure that the relevant sections
are completed at each subsequent regular
service visit.
page 2
IN CASE OF GAS LEAKS
If a gas leak is found or suspected, turn off the
gas supply at the meter immediately and contact
your Installer or Transco (under 'Gas' in the phone
directory).
NEVER HANG CLOTHES OR OTHER
ITEMS OVER THE APPLIANCE.
SERVICING YOUR BOILER
We strongly recommend that your Boiler is serviced
annually for reasons of safety and economy. Your
Installer or British Gas Service will be able to advise
you.
THIS APPLIANCE MUST BE EARTHED
Electricity supply:
A standard 230 volt ~ 50Hz supply is required. The
appliance must be protected by a 3 amp fuse.
SAFE INSTALLATION
Installation of this appliance must be carried out by
a CORGI Registered Installer and be in accordance
with the relevant requirements of the current GAS
SAFETY (Installation and Use) REGULATIONS and
any other regulations applying in your area.
Warnings
OVERHEAT CUT-OFF DEVICE
Your boiler is fitted with an additional
safety device which shuts down the
appliance should the system
overheat. If the pilot is extinguished
for no apparent reason and cannot
be re-ignited, this overheat cut-off
device may have operated.
NOTE: Any interruption to the
electricity supply may cause the
device to operate. In the case of
persistent operation of the device,
turn off the boiler and consult your
service engineer as an appliance or
system fault is indicated.
If the boiler wiring has been altered
to allow gravity domestic hot water
operation, the overheat thermostat
will be inoperable.
RESETTING
To reset the device follow these
instructions.
Allow the boiler to cool if hot.
Remove the lower door panel by
following the instructions on the
opposite page.
Locate the red/brown reset button
adjacent to the boiler thermostat
knob. Press the button
to reset the overheat
thermostat.
Re-ignite the boiler
by following the
instructions on the opposite page.
Turn off the electricity supply to
the appliance at the mains.
To turn off the pilot: Turn gas
control knob to off position
marked 0.
NOTE: The gas control knob cannot
be depressed until ignition restart
interlock device in gas valve has
disengaged. This takes 60 seconds
approximately.
Turn off the gas supply at
either the appliance gas cock
or the meter.
If your home is to be left unoccupied
for long periods during cold weather,
the whole system should be drained,
unless a frost-stat is fitted. Your
installer will advise you about
draining the system.
NOTE: Depending on the design of
your central heating system, the
pump may keep running for
approximately 3 minutes after any
external controls e.g. timer,
programmer have turned the
appliance off. This is perfectly normal
and is because your Solo 2 RS is
fitted with a timed pump overrun to
prevent overheating.
TO SHUT DOWN THE BOILER
1
2
3
page 3