Barska AX11652 Handleiding
Lees hieronder de 📖 handleiding in het Nederlandse voor Barska AX11652 (2 pagina's) in de categorie Kluis. Deze handleiding was nuttig voor 43 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/2
See reverse side for more information
10/12
BC266
User’s Manual for Biometric Safe
* Actual model may vary
A. Initialization Button
B. Battery Compartment
C. Bolts
D. Fingerprint Scanner
E. Indicator Lights
F. Wake-Up Button
GETTING STARTED
1. Remove Emergency Keys from accessory package
2. To expose the Emergency Key access, remove Logo Plate
(G) screws with provided tool
3. Insert Emergency Key into key access, push and turn
counter-clockwise
4. Turn Handle (H) clockwise to open the safe
5. Continue with INSTALL BATTERIES
INSTALL BATTERIES
1. Remove Battery Compartment (B) cover
2. Insert 4 AA batteries and restore battery cover
3. Continue with FINGERPRITN REGISTRATION
FINGERPRINT REGISTRATION
IMPORTANT: The safe is in either Pre-registered mode or
Factory Default mode, test safe to determine factory settings
below
Pre-registered mode: Safe can NOT be opened with any
fingerprint(s)
Factory Default mode: Safe can be opened with ANY
fingerprint(s)
1. With the safe door open, press and release Initialization
Button (A)
2. Immediately place a finger on the Fingerprint Scanner (D)
- Hold finger still
- 1 beep will be heard recognizing the fingerprint; followed by
2 consecutive beeps
- Remove finger
- Registration is complete
Successful Registration
Registration is successful when a total of 3 beeps are heard
Unsuccessful Registration
2 short beeps will be heard; repeat registration process again
3. To register another fingerprint - repeat steps 1 – 2
4. Continue with TEST (NON) REGISTERED FINGERPRINTS
TEST (NON) REGISTERED FINGERPRINTS
1. Test multiple Non-Registered fingerprints
- Close safe door, turn Handle (H) counter-clockwise to
lock the safe
- Press and release Wake-Up Button (F)
- Place a non-registered finger on the Fingerprint Scanner (D)
- Turn Handle (H) clockwise, the door should not open
- If the door opens with a non-registered fingerprint,
registration was unsuccessful; the safe is still in Factory
Default mode
- Repeat steps under FINGERPRINT REGISTRATION, and
test multiple non-registered fingerprints
2. Test a Registered fingerprint
- With door closed, press and release Wake-Up Button (F)
- Place a registered finger on the Fingerprint Scanner (D)
- Turn Handle (H) clockwise, the door should open
- Registration was successful, if it only opened with registered
fingerprint(s)
CLOSE/OPEN SAFE DOOR
CLOSE: Close safe door, turn Handle (H) counter-clockwise to
lock the safe
OPEN: Press and release Wake-Up Button (F)
- Place a registered finger on Fingerprint Scanner (D)
- Turn Handle (H) clockwise to open the safe
BEEP SOUND OPTIONS
Beep OFF: Press and HOLD the Initialization Button (A) (20 -
30 seconds) until the Indicator Lights (E) flash green once
- RELEASE the Initialization Button
Beep ON: Press and HOLD the Initialization Button (A) (20 -
30 seconds) until the Indicator Lights (E) flash green, followed
by 1 beep
- RELEASE the Initialization Button
OPEN SAFE WITH EMERGENCY KEY
1. To expose the Emergency Key access, remove Logo
Plate (G) screws with provided tool
2. Insert Emergency Key into key access, push and turn key
counter-clockwise, and turn Handle (H) clockwise to open
the safe
NOTE: Store Emergency Keys in a secure place, NOT inside of
the safe
OPEN SAFE WITH EXTERNAL BATTERY PACK
Use this option when internal batteries are low
1. Insert 4 AA batteries into External Battery Pack (I)
2. Plug into External Battery Access (J)
G. Logo Plate and Emergency
Key Access
H. Handle
I. External Battery Pack
(batteries not included)
J. External Battery Access
WARNING
- New Safe is in either Pre-registered mode or Factory
Default mode; ANY fingerprint can open the safe. Only
a successfully registered Fingerprint(s) can terminate
Factory Default mode.
- Register at least two different fingerprints and test a
few times before closing the safe door.
- Test with a non-registered fingerprint. If the safe
opens, the safe is still in Factory Default mode.
- Avoid leaving safe door open and unattended; it will
allow unauthorized individuals to add their fingerprints
and/or reprogram the safe, gaining full access to the
safe and the contents.
- Test the Emergency Keys and store them in a secure
place, NOT inside of the safe.
- To maximize the security and performance of the
safe, test registered fingerprints every 6 months.
- Initialization button cover must be restored after
every use.
- If user resets the safe to Factory Default mode: ANY
fingerprint can open the safe.
A
B
C
F
D
E
G
HH
HJ
I
L
o
c
k
U
n
l
o
c
k
Read all instructions before using this safe.
BARSKA warrants this new safe to be free of original defects in
material and/or workmanship under normal use for a period of twelve
(12) months from the date product is received by purchaser. This
warranty does not include damage caused by improper installation or
maintenance. Damage from misuse, abuse, accident (such as
dropping), normal wear and tear, fire, flood, or acts of nature. Damage
from service or repairs other than those performed by BARSKA.
Labor, cost and shipping charges for the removal and replacement of
defective parts beyond the initial twelve-month warranty period. All
transportation and shipping charges. Removing or altering the seal
under any circumstances will automatically void the warranty.
This warranty is limited to original purchaser and is not transferable.
This warranty applies only to products purchased in the United States.
Please email info@barska.com or call 1.888.666.6769 for Return
Merchandise Number (RMA#) before any returns. The RMA number
must appear on the outside of the shipping package. Product must be
packed carefully and sturdily in its original packaging to prevent
damage in transit and returned freight pre-paid to:
BARSKA OPTICS
Repair Department
1721 Wright Avenue
La Verne, CA 91750
Please include all of the following when returning BARSKA products
for service and/or replacement:
1. Please write your complete details (Name, Address, Telephone #,
E-mail address, RMA#, etc.)
2. Purchase receipt or Proof of Purchase. (Original/Copy)
3. A brief explanation of the defect.
4. A Check/Money Order of to cover inspection, shipping and $60.00
handling.
*Please allow 6-8 weeks for delivery.
BARSKA will examine and test returned product and repair or replace
defective part(s) or units with new part(s) or a new unit if necessary
within the warranty period. Purchaser is required to remit to $60.00
BARSKA for return shipping and handling at time product is returned.
If repair is required after warranty period expiration, purchaser will be
charged for replacement parts and return shipping.
BARSKA® Optics shall not be liable for any consequential, incidental
and/or contingent damages whatsoever. We will not pay shipping,
insurance or transportation charges from you to us, or any import
fees, duties and or taxes. This warranty supersedes all previous
BARSKA® Optics warranties.
Biometric Safe
1 YEAR LIMITED WARRANTY
BC240 9/12
3. Press and release Wake-Up Button (F)
- Place a registered finger on Fingerprint Scanner (D)
- Turn Handle (H) clockwise to open the safe
DELETE ALL STORED FINGERPRINTS / RESET TO
FACTORY DEFAULT MODE
1. Open safe, remove Battery Compartment (B) cover and
all 4 AA batteries
2. Press and release Wake-Up Button (F) a few times until no
beeps are heard
3. Press and HOLD the Initialization Button (A)
- Re-insert batteries; on the 4th battery you will hear 1
beep, followed by 2 consecutive beeps indicating safe is
in Factory Default mode
4. RELEASE Initialization Button (A)
5. Repeat steps 1-3 if a total of 3 beeps are not heard
6. Restore Battery Compartment (B) cover
7. All fingerprints stored in the safe have been deleted
NOTE: The safe is in Factory Default mode, ANY fingerprint
can open the safe
8. Continue with FINGERPRINT REGISTRATION and TEST
(NON) REGISTERED FINGERPRINTS
LOW BATTERY WARNING
1. When the door is closed and 3 repetitive beeps are heard,
and Indicator Lights (E) flash red, it indicates the batteries
are low
2. Replace batteries immediately
- Open safe, remove Battery Compartment (B) cover and
all 4 AA batteries
- Insert 4 new AA batteries and restore Battery
Compartment (B) cover
NOTE: All registered fingerprints remain stored
CARE AND MAINTENANCE
- To maximize the security and performance of the safe, keep
Fingerprint Scanner (D) clean; use a dry cloth to remove
any smudges or prints off the Fingerprint Scanner after
each use
- Test registered fingerprints every 6 months
- Keep liquids away from the control panel. Spills on the
control panel will cause damage and possibly electric shock
- Secure safe in a proper area to prevent from falling and
causing damage or injury
- DO NOT disassemble the product. For all repairs, contact
BARSKA Customer Service
- DO NOT use chemicals or cleaning agents to clean the safe
MOUNTING INSTRUCTIONS
The safe may be mounted to a wall or
floor. Be aware of the load bearing.
Failure to do so can result in personal
injury and/or damage to property. Use
appropriate tools when performing
work and always use eye protection
Wall Mounting
Do not mount the safe without
anchoring to the wall
- Find the studs in the wall, at your
desired location. Most studs
are 16 inches or 24 inches apart
- Check the wall for concealed wires
or pipes
- Measure the location of the pre-set drill holes; mark their exact
position onto the wall ensuring that the studs or anything else
behind will not interfere
- Drill the appropriate size holes for the anchors you are using
- Carefully press the anchor into the holes at this time
- Mount the safe by running screws from inside of the safe
and securing to anchors; ensure the safe is mounted securely
Floor Mounting
- Use proper drill tools depending on the type of floor you are
mounting the safe (wood, tile, or concrete)
- Measure the location of the pre-set drill holes; mark their
exact position onto the floor
- Drill the appropriate size holes for the anchors you are using
- Carefully press the anchor into the holes at this time
- Mount the safe by running screws from inside of the safe
and securing to anchors; ensure the safe is
mounted securely
Mounting Holes
* Actual model may vary
© 2012 BARSKA®
1721 Wright Ave | La Verne, CA 91750 | USA
(t) 888.666.6769 | (f) 909.445.8169 | www.barska.com
Product specificaties
Merk: | Barska |
Categorie: | Kluis |
Model: | AX11652 |
Heb je hulp nodig?
Als je hulp nodig hebt met Barska AX11652 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Kluis Barska
26 Augustus 2023
26 Augustus 2023
26 Augustus 2023
26 Augustus 2023
26 Augustus 2023
26 Augustus 2023
26 Augustus 2023
26 Augustus 2023
26 Augustus 2023
26 Augustus 2023
Handleiding Kluis
- Kluis Philips
- Kluis Honeywell
- Kluis Abus
- Kluis Avanti
- Kluis Burg-Wachter
- Kluis Dometic
- Kluis Duralock
- Kluis EasySafe
- Kluis Ferm
- Kluis Filex
- Kluis FireKing
- Kluis First Alert
- Kluis Fluke
- Kluis Hama
- Kluis Handson
- Kluis M-Locks
- Kluis Master Lock
- Kluis Nauta
- Kluis Nedis
- Kluis Perel
- Kluis Phoenix
- Kluis Protector
- Kluis Renkforce
- Kluis ROMA
- Kluis Rottner
- Kluis Royal Safe
- Kluis Royal Sovereign
- Kluis Salvus
- Kluis Sentry
- Kluis Sistec
- Kluis SMC
- Kluis Sygonix
- Kluis Technomax
- Kluis Thule
- Kluis Toolland
- Kluis Topcraft
- Kluis Tulox
- Kluis Varo
- Kluis Westfalia
- Kluis Workzone
- Kluis Yale
- Kluis Jewel
- Kluis Juwel
- Kluis Olympia
- Kluis Oxloc
- Kluis First Austria
- Kluis Guzzanti
- Kluis Steren
- Kluis Conrad
- Kluis SereneLife
- Kluis Challenge
- Kluis MSW
- Kluis Hard Head
- Kluis Kidde
- Kluis SentrySafe
- Kluis CAWI
- Kluis Kreator
- Kluis Fichero
- Kluis Kreator-Varo
- Kluis Rottner Tresor
- Kluis Olymp
- Kluis Suncast
- Kluis Winholt
- Kluis Homak Security
- Kluis NOFIRE
- Kluis Stamony
Nieuwste handleidingen voor Kluis
15 November 2024
15 November 2024
15 November 2024
13 November 2024
15 Oktober 2024
15 Oktober 2024
15 Oktober 2024
15 Oktober 2024
1 Oktober 2024
1 Oktober 2024