Barco R9004787 Handleiding


Lees hieronder de šŸ“– handleiding in het Nederlandse voor Barco R9004787 (2 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 83 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/2
Card
Slot #2
(Any
Event
Master
card)
USB 2.0
Port
RJ45
Connector
(Ethernet)
Genlock BNC Input
and Reference
Output
Link Connectors
Top = 1
Bottom = 2
Card Slot #1
(Any Event Master card)
Power Switch
and
AC Connector
Barco Technical Support:
USA:
EMEA:
China:
APAC:
Support:
P/N 26-1502004-00 Rev 02
Recessed Reset
Switch
Event Master EX Screen Management System: ā€“
Expansion Box
Quick Start Guide
Status LED USB 2.0 Port
Quick Setup and Operations
1. Connect all sources, displays, and peripherals to the EX extension
box according to your eventā€™s requirements.
2. Power up the EX and all peripherals.
3. Set up the computer on which you will run the Event Master
control software for a static IP address of 192.168.0.200.
The network ID must be 192.168.0. You may assign the host ID
yourself, but avoid the default static IP address, which is
192.168.0.185.
If you plug the USB thumb drive into the EX expansion box, the
system creates a "whoareyouEX.txt" ļ¬le that contains the IP
address and the Unit ID.
4. Connect the EX unit via an Ethernet cable to a computer on which
the Event Master control software is installed.
5. Use the front-panel LED to verify that the EX is running correctly.
On power up, the LED may be in one of four states:
ā€¢Solid red The operating system is running.ā€“
ā€¢Quickly blinking red 3 fast blinks indicates overheating.ā€“
ā€¢Steadily blinking red 1 blink per second indicates PCIe errors.ā€“
ā€¢Solid green The main code is running; the system is ready.ā€“
Identify EX Units
1. Select the EX unit (in the
Selection area or the
Diagram area).
2. Go to the Adjust tab in the
Conļ¬guration area.
3. Select the Setup
sub-tab and check the
Flash LED(s) box.
The front and rear status
LEDs of the selected EX
unit will blink.
Factory Reset
If necessary, press the
recessed reset switch and hold
it for ļ¬ve seconds to restore the
Refer to the Event Master devices Userā€™s guide
(R5905948) for detailed system speciļ¬cations,
descriptions and operation instructions.
Status LED
Link Connections
An Event Master unit can link with other Event Master units. Depending on the linking conļ¬guration, linked units share inputs, and they
expand the number of outputs. For more information on linking, see Section 6.17 "Conļ¬guration Menu > Linkingā€ in the Event Master
Devices User's Guide, or see the instructional videos on the Barco Folsom IP YouTube site.
For links to other quick-start guides and the , see the Technical Downloads tab for each product on Event Master Devices User's Guide
the Barco Presentation switchers page at: https://www.barco.com/en/Products/Image-processing/Presentation-switchers
1. Check the cable orientation for keying. The cable ļ¬ts in only one
orientation.
2. Fully insert the cable into the connector on the Link Card.
3. If the cable resists full insertion, do not force it; pull the cable out,
check its orientation, and reinsert it.
4. Make sure that the latch is properly engaged.
5. Always use the release when removing the cable.
Improper insertion or removal of Link cables can damage the
connectors and is not covered under the product warranty.
ā€¢To link two daisy-chained EX units to an E2, connect the Link
cables from the E2 to the EXes as follows:
E2 VP ID 0, Link Card slot 1, Link 1 >> EX VP ID 1, Link 2
EX VP ID 1, Link 1 >> EX VP ID 2, Link 2
2. Make sure that the E2 and the EX unit (or units) have diļ¬€erent IP
addresses.
The E2 default IP address is 192.168.0.175, and the EX default
IP address is 192.168.0.185. If more than one EX is linked, be
sure to change the IP addresses on additional units.
For links to instructional videos, see the Barco Folsom IP YouTube site at: .https://www.youtube.com/user/BarcoFolsomIP
If you press the reset switch and release it after
fewer than ļ¬ve seconds, the unit toggles between
Static IP mode ( ) and DHCP LED blinks 2 times
mode ( ).LED blinks 3 times
+1 (866) 374-7878
+32 (56) 36 8019
40088 22726
+603-78803362
www.barco.com/en/support
Example: Linking an EX (or a Pair of EX Units) to an E2
Each E2 is equipped with two link cards, always located in slots 1
and 2. Link cards are identiļ¬ed by a yellow stripe at the top.
Each EX has two Link sockets.
Be sure that you properly align the Link cable connectors prior to
insertion. Connectors should insert easily with almost no
resistance, until the lock is about to engage. Be sure that the lock
engages fully to ensure proper contact. Make sure that you use the
locking mechanism and then push each cable until it locks in place.
ā€¢To link an EX to an E2, connect the Link cables from the E2 to
the EX as follows:
E2 VP ID 0, Link Card slot 1, Link 1 >> EX VP ID 1, Link 2
3. Connect all devices to network
Ethernet.
4. Start the Event Master Toolset
version 4.0 or higher.
5. Drop the E2 in the GUI.
The EX unit cabled to the E2
appears as a grayed-out box
below the E2 unit in the Diagram
area. In the grayed-out EX box a
blue button allows you to add the
EX to the system as a slave.
6. Click the blue add button to add
the EX unit.
If you are adding two daisy-chained EX units, you must add the ļ¬rst
EX in the chain before the second EX in the chain is displayed,
then repeat Step 4 to add the second EX in the chain.
Linking
EX extension box to factory
settings.
Cards are hot-swappable.not
The EX expansion box ships without input or output
cards. Cards must be installed before you set up and
operate the unit.
P/N 26-1502004-00 Rev 02
Programming Menu
P1: Select thumbnails for Inputs & Stills Press , or ā€“Refresh All
select the thumbnails to represent Inputs and Stills. Either capture a
live thumbnail or select an image ļ¬le.
P2: Create Source Files Under the Input tab create any additional ā€“
source ļ¬les (optional). Select the Adjust tab and perform any
additional adjustments and press . Repeat for all Inputs/Save
Sources and save.
P3: Drop Inputs to Aux Destinations Under the Input tab select an ā€“
Input and drop it to an Aux Destination. Select the Adjust tab and
perform any additional adjustments. Repeat for all Inputs and save.
P4: Presets Select Screen(s) and under Adjust and Preset tabs ā€“
create a new preset or manage existing ones. Repeat to create
multiple Presets.
Conļ¬guration Menu
C1: Discovery - The Event Master control software automatically
discovers the devices connected to the network and lists them on
the left hand side of the conļ¬guration screen.
C2: Connect - Click on the device that you want to connect, drag it
in the middle area, and the software establishes communication
with the unit. You can also connect to the EX by typing the IP
address manually.
C3: System Parameters - Select the desired Native Rate, Genlock
Mode, and Preset Conļ¬‚ict Mode.
C4: Add Inputs - Select and deļ¬ne input connectors as Inputs.
C5: Add Outputs - Select and deļ¬ne output connectors as Outputs.
C6: Add Aux Destinations - Select the corresponding output
connector(s) from the same card and add them to AUX
Destinations.
C7: For any Input, Output, or AUX Destination, select the Adjust tab
and perform any necessary adjustments.
C1: Discover
C2: Connect
C5: Add
Outputs
C4: Add
Inputs
C3: System Parameters
(Native Rate, Genlock Mode, and
Preset Conļ¬‚ict Mode)
P1: Select thumbnails for
Inputs & capture Still stores
P3: Drop
Inputs/Stills
into AUX
Destinations
P4: Create
Presets
Settings Menu
S1: The Dashboard provides card status and other diagnostic information.
S2: Tools allow users to perform Backup and Restore operations or to download the latest software from the Barco Web site.
C4
C5
S1
S2
P1
P2
P3
P4
C1
C2
C3
C6
C7
P2: Create
Sources
from
Inputs
Barco Technical Support:
USA:
EMEA:
China:
APAC:
Support:
+1 (866) 374-7878
+32 (56) 36 8019
40088 22726
+603-78803362
www.barco.com/en/support
C6: Add AUX
Destinations
Event Master EX Screen Management System: ā€“
Expansion Box
Quick Start Guide


Product specificaties

Merk: Barco
Categorie: Niet gecategoriseerd
Model: R9004787

Heb je hulp nodig?

Als je hulp nodig hebt met Barco R9004787 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Barco

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd