Ballymore Cantilever CL-10-42 Handleiding
Lees hieronder de 📖 handleiding in het Nederlandse voor Ballymore Cantilever CL-10-42 (5 pagina's) in de categorie Ladder. Deze handleiding was nuttig voor 26 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/5
Multimedia connection system
- MA.. Ref. no.:
Stand: Sep-19
Operating Instructions
Multimedia connection system
1. Safety instructions
Electrical equipment must only be installed and assembled by
qualied electricians.
Always follow the relevant accident prevention regulations.
Failure to comply with these instructions may ult in damage to res
the device, re or othe hazards. r
Proper signal transmission is only ensured when the appropriate
accessories are used and the specied maximum cable lengths are
observed, as well as the minimum permissible distance of 0.3 m
from current-carrying cables and sources of interference (electronic
ballasts, dimmers, ESLs, etc.) are observed.
These operating instructions are an integral component of the
product, and must be retained by the end user.
2. Function
The multimedia connection system serve to connect input and output
devices for transmission of audio/ video signals and data.
The available functions depend on the devices that are
connected. To select the suitable socket, note the information
from the manufacturer of the connected devices.
Intended use
Only suitable for use in indoor areas
Can be used in multiple combinations
Flush-mounting in wall box according to DIN VDE 0606
Connection of audio/video devices via „Plug & Play“
3. ration Ope
CAUTION!
The use of non-standardised connecting cables and connectors can
cause device malfunctions.
The devices may be destroyed.
Use only approved connecting cables and connectors.
Multimedia connection system
- .: MA.. Ref. no
2
3.1. Connecting multimedia devices
Insert connector of the connecting cable from the signal source,
e.g. from a DVD or MP3 player, into the jack of multimedia socket.
sert connector of the connecting cable from a playback device, In
e.g. from an LCD/plasma television or stereo system, into the jack
of a second multimedia socket.
Insert connectors into the jacks straight and without using force.
Twisting or tilting the connector may deform the contacts.
Application examples
Connection
Devices
Cinch
Audio systems, AV receivers, active loudspeakers
S-Video
SAT receivers, televisions, projectors, iPod
docking stations, video cameras
USB
iPods, printers, storage media, digital cameras
TRS
3.5 mm
MP3 players, CD/DVD players, sound cards,
audio systems
VGA
PCs/laptops, projectors, monitors
HDMI
High denition plasma/LCD televisions, SAT
receivers, projectors, game consoles, DVD/Bluray
players, DVD/HDD recorders, video cameras
Information for electricians
4. Assembly
4.1. Connecting and installing the multimedia connection
system
The connecting cable has been laid, the wall box is installed in the wall.
Recommendation: use Kaiser „Electronics Box“ (Art. no. 1068-02
or 9062-74) in order to maintain the permissible bending radii.
Insert connector of the connecting cable into the corresponding jack
on the rear of the multimedia connection system.
Screw insert to the wall box in the tight orientation via the
supporting ring.
Place centre plate into the frame.
Mount centre plate together with the frame on the insert using
screwless terminals.
The multimedia connection system can be commissioned.
5. Commissioning
CAUTION!
Short- rcuit if devices that are switched on are connected. ci
Devices may be destroyed.
Switch all devices o before connecting them.
Multimedia connection system
- .: MA.. Ref. no
3
5.1. Carrying out a functional test
Multimedia connection system is connected.
Activate the desired functions and check the signal transmission at
the signal sources and the playback device, e.g. play a DVD and
check picture/sound reproduction on a television set.
The multimedia connection system is ready for operation.
6. Appendix
6.1. Technical data
Cinch Audio
Rated voltage: DC 50 V
Frequency ranges: 20 Hz ... 20 kHz
Contact resistance: ≤ 20 mΩ
Insulation resistance: ≥ 100 MΩ
Electric strength: AC 500 V~ (50/60 Hz)
for 1 min 2 mA
Insertion and removal forces: 3 ... 25 N
Insertion cycles: ≥ 1000
Gender changer: white (left) red (right) ,
Contact material: gold-plated
Installation depth: 14 mm
Ambient temperature: -5 ... +45 °C
TRS 3.5 mm
Rated voltage: DC 50 V
Frequency ranges: 20 Hz ... 20 kHz
Contact resistance: ≤ 20 mΩ
Insulation resistance: ≥ 100 MΩ
Electric strength: AC 500 ... 2000 V~
DC 800 V
Insertion and removal forces: 4.9 ... 14.7 N
Insertion cycles: ≥ 2000
Gender changer: 3.5 mm Audio Stereo, 180 °
Contact material: gold-plated
Ambient temperature: -5 ... +45 °C
Composite Video
Rated voltage: DC 50 V
Frequency ranges: ≤ 160 MHz
Contact resistance: ≤ 20 mΩ
Insulation resistance: ≥ 100 MΩ
Electric strength: AC 500 V~ (50/60 Hz)
for 1 min 2 mA
Insertion and removal forces: 3 ... 25 N
Insertion cycles: ≥ 1000
Gender changer: yellow
Contact material: gold-plated
Installation depth: 14 mm
Ambient temperature: -5 ... +45 °C
Product specificaties
Merk: | Ballymore |
Categorie: | Ladder |
Model: | Cantilever CL-10-42 |
Heb je hulp nodig?
Als je hulp nodig hebt met Ballymore Cantilever CL-10-42 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Ladder Ballymore
8 Juli 2023
6 Juli 2023
4 Juli 2023
1 Juli 2023
29 Juni 2023
27 Juni 2023
25 Juni 2023
25 Juni 2023
24 Juni 2023
23 Juni 2023
Handleiding Ladder
- Ladder Alecto
- Ladder Altrex
- Ladder Batavia
- Ladder Brennenstuhl
- Ladder FireAngel
- Ladder First Alert
- Ladder Foppapedretti
- Ladder GRE
- Ladder Max
- Ladder Mr Safe
- Ladder Powerfix
- Ladder Silverline
- Ladder Thule
- Ladder Vonroc
- Ladder Clas Ohlson
- Ladder Fieldmann
- Ladder Biltema
- Ladder Probuilder
- Ladder Hard Head
- Ladder Kelfort
- Ladder Versaladder
- Ladder Cosco
- Ladder GEV
- Ladder Kidde
- Ladder Telesteps
- Ladder JANDY
- Ladder Krause
Nieuwste handleidingen voor Ladder
2 April 2024
5 Maart 2024
20 Februari 2024
20 Februari 2024
20 Februari 2024
20 Februari 2024
20 Februari 2024
20 Februari 2024
20 Februari 2024
20 Februari 2024