OWNERā€™S MANUAL
AMP1200VS
AudioSourceĀ®
13970 SW 72nd Ave
Portland, OR 97223
503.914.4688
www.audiosource.net AMP1200VS Ownerā€™s Manual 72015
Congratulations on your purchase of the AudioSourceĀ® AMP1200VS.
Please take a few moments to read this entire manual, and be sure to
retain this document for future reference. Please read and observe all
safety instructions detailed on page 2.
NOTE: If any part of this product is damaged or missing, please call your
dealer or AudioSourceĀ® directly at 1.877.715.5439 or 503.914.4688.
Please read your warranty and retain your receipt and original carton
for possible future use.
For more information about AudioSourceĀ® electronics, speakers and
accessories please visit www.audiosource.net
FEATURES:
SPECIFICATIONS
Stereo (8 ohm): 12 x 40W per channel, <0.2% THD+N
Stereo (4 ohm): 12 x 40W per channel, <0.2% THD+N
Bridged Mono (8 ohm): 80W, 1kHz, <0.2% THD+N
Frequency Response: 10Hz ~ 50kHz, +0dB/ -3dB
Signal to Noise Ratio:
100dB below 150W output into 8 ohms
Channel Separation: 70dB @ 1kHz, referred to 150W output
into 8 ohms
Input Sensitivity: Variable, 350mV to 2.8V for rated power
into 8 ohms
AC Power Consumption: 1000W maximum
Net Weight: 30lbs / 13.6kgs
Gross Weight: 36lbs / 16.3kgs
Multi-Zone Power Amplifier
AMP1200VS
12 Independent Channel inputs, 2 Buss Inputs
2 Buss Outputs
Independent Channel Gain Controls
Manual, Auto, or Triggered On/Off Modes
Bridgeable Channel Outputs
Rack Mountable (Rack Mount Included)
LED Status Indicator Lights
Phoenix-Style Speaker Connectors
Stable Class A/B Design
Extensive Protection Circuitry
4.0ā€
(102mm)
16.5ā€ (419mm)
14.25ā€
(361mm)
MULTI-ZON E POWER AMPLIFIER
AMP1200VS
13. Unplug the apparatus during lightning storms or when unused for long periods
of time.
14. Refer all servicing to qualified personnel. Servicing is required when the
apparatus has been damaged in any way, such as power supply cord or
plug is damaged, liquid has been spilled or objects have fallen into the
apparatus has been exposed to rain or moisture, does not operate normally,
or has been dropped.
15. WARNING: To reduce the risk of fire or electric shock, do not expose this
apparatus to rain or moisture. The apparatus shall not be exposed to
dripping or splashing and that objects filled with liquids, such as vases,
shall not be placed on apparatus.
16. WARNING: The mains plug/appliance coupler is used as disconnect device,
the disconnect device shall remain readily operable.
17. This equipment is a Class II or double insulated electrical appliance. It
is designed in such a way that it does not require a safety connection
to electrical earth.
18.
- This lightning flash with arrowhead symbol within an equilateral triangle is
intended to alert the user to the presence of non-insulated ā€œdangerous voltageā€
within the productā€™s enclosure that may be of sufficient magnitude to constitute
a risk of electric shock.
- Warning: to reduce the risk of electric shock, do not remove cover (or back) as
there are no user-serviceable parts inside. Refer servicing to qualified personnel.
- The exclamation point within an equilateral triangle is intended to alert the user
to the presence of important operating and maintenance instructions in the
literature accompanying the appliance.
AMP1200VS
OWNERā€™S MANUAL
13970 SW 72nd Ave, Portland, OR 97223 ā€¢ 503.914.4688 ā€¢ www.audiosource.net
2
CAUTION
RISK OF ELECTRICAL SHOCK
DO NOT OPEN
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE THE COVER. NO
USER SERVICABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL!
IMPORTANT SAFETY INSTRUCTIONS
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. The ventilation should not be impeded
by covering the ventilation openings with items such as newspaper, table-
cloths, curtains etc. Install in accordance with the manufacturerā€™s instructions.
8. Do not install near heat sources such as radiators, heat registers, stoves,
or other apparatus (including amplifiers) that produce heat. No open flame
sources, such as lighted candles, should be placed on the apparatus.
9. Do not defeat the safety purpose of the polarized or grounding type plug.
A polarized plug has two blades with one wider than the other. A grounding
type plug has two blades and a third grounding prong. The wide blade or
third prong is provided for your safety. If the provided plug does not fit into
your outlet, consult an electrician for replacement of the obsolete outlet.
MAGNETIC FIELD: !!CAUTION!! Do not locate sensitive high-gain equipment such as preampliļ¬ers or tape decks directly above or below the unit. Because
this ampliļ¬er has a high power density, it has a strong magnetic ļ¬eld, which can induce hum into unshielded devices that are located nearby. The ļ¬eld is
strongest just above and below the unit. If an equipment rack is used, we recommend locating the ampliļ¬er(s) in the bottom of the rack and the preampliļ¬er
or other sensitive equipment at the top.
EXPLANATION OF
SAFETY SYMBOLS
The exclamation point within an equilateral triangle is intended to alert the user of the presence of important
operating and maintenance (servicing) instructions in the literature accompanying the appliance.
The lightning ļ¬‚ash with the arrowhead symbol within an equilateral triangle is intended to alert the user to the
presence of uninsulated ā€œdangerous voltageā€ within the productsā€™ enclosure that may be of sufļ¬cient magnitude
to constitute a risk of electric shock to persons.
10. Protect the power cord from being walked on or pinched particularly at the
plugs, convenience receptacles, and at the point of exit from the apparatus.
11. Only use attacheements/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or
table specified by the manufacturer, or sold with
the apparatus. When a cart or rack is used, use
caution when moving the cart/apparatus
combination to avoid injury from tip-over.
ā€¢ WARNING: TO PREVE FIRE OR SHOCK HAZARD, DO NNT OT T PPARA EXPOSE THIS APPLIANCE O RAIN OR MOISTURE. THE A TUS SHALL NOT
BE EXPOSED T HAT VO DRIPPING OR SPLASHING AND T OBJECTS FILLED WITH LIQUIDS, SUCH AS ASES, SHA NLL OT D BE PLACE
ON APPARATUS.
ā€¢ WARNING: TO PREVENT FIRE OF SHOCK HAZARD, DO NOT USE THIS PLUG WITH AN EXTENSION CORD, RECEPTACLE OR OTHER OUTLET
UNLESS THE BLADES CAN BE FULLY ER T INS TED O PREVENT BLADE EXPOSURE.
ā€¢ WARNING: THE MAINS PLUG IS USED AS DISCONNECT CT DEVICE. THE DISCONNE DEVICE SHALL REMAIN READILY AVAILABLE.
ā€¢ WARNING: ONLY USE ATTACHMENTS OR ACCESSORIES SPECIFIED OR PROVIDED BY UF THE MAN ACTURER.
MULTI-ZONE POWER AMPLIFIER
AMP1200VS
AMP1200VS
OWNERā€™S MANUAL
13970 SW 72nd Ave, Portland, OR 97223 ā€¢ 503.914.4688 ā€¢ www.audiosource.net 3
1.
2.
FRONT PANEL CONTROLS
4.
5.
6.
8.
REAR PANEL CONTROLS
Figure 1. Front Panel
3.
1
2
9.
10.
11.
Figure 2. Rear Panel
Master Power Switch / Indicator LED
Front panel pushbutton power switch turns the ampliļ¬er on and off. When the
switch is on and the indicator LED is red, the ampliļ¬er is in standby mode. The
remote turn on switch (located on the rear) is either in the ā€œtriggerā€ or ā€œautoā€
position. When the LED is blue, the ampliļ¬er is fully active. The master power
switch will turn off the ampliļ¬er no matter which power mode has been selected.
Zone Status Indicators
Each pair of channels or ones has bi-color LED z a to indicate its ope ationalr
status. These indicators pr video quick and easy trou leshootingb of the system. If the
circuitry deter a m do e ve low mines that channel ust be shut wn due to xcessi heat or
impedance (a sho t), only ther channels that ar af ectede f will be tu ned offr causing
the zone LED to tu rn red. The remaining zones will conti uen to ope ater and maintain
a b lue LED statu s. Once the condition has been corrected for zthe one in question,
the status LED will retu n to lur b e.
Note: When the pow er LED is red and the z one status LEDS are not lit (off) indicates
the unit is in stand y modb e.
3 6 7 8
11
4 5 9 10 12
BUS Line Inputs / Outputs
The AMP1200VS has two common or BUS inputs that receives audio signals
from standard line-level audio sources and sends them to any or all channels. The
BUS line outputs are direct feed-through to allow the BUS inputs to be fed to other
ampliļ¬ers. Be sure to use high quality RCA cables that feature low impedance,
shielding and high quality connectors.
Remote Turn-On Switch
This s witch selects the tu n-onr sti ulim that will put the amplifier in ready mode.
ā€œTriggerā€ setting relies on 3-30V AC/DC voltage going into the trigger input to
activate the ampliļ¬er. ā€œAutoā€ setting senses a signal on the RCA line-level inputs
and automatically puts the amp in ready mode. ā€œOnā€ setting puts the amp
constantly in ready mode so that it can be controlled by the master power switch
on the front panel. In ā€œAutoā€ mode, the amplifier will take approsimately 15
minutes to return from ready to standby mode.
Trigger Input / Output
The trigger input is a handy feature when connecting the amplifier to an
automated audio system. The 3.5mm miniplug jack will accept a 3-30V AC/DC
output from another device, or from a separate power supply. When the trigger
input is energi ed,z the amp tu nsr from standby to ON mode. When using the
AMP1200VS with a receiver without a trigger output, the voltage can come from a
12V wall wart (3.5mm tip-positive connector) plugged into the receiverā€™s switched
outlet and the trigger input. The AMP1200VS can also provide an output trigger
voltage (12DC @500mA max.) to turn on and off other devices in the audio system.
When the amplifier turns off (standby mode), the voltage will drop to zero.
Channel Gain Control
Each channel has its own independent level adjustment. This allows the output
level of each speaker to be perfectly matched to its area. It can also be used to
limit the maximum audio level in a certain area.
Bridging Switch
By simply flipping a single switch, two channels can be combined to increase the
total power output. This is helpful when extra power is needed in certain areas.
Note: The minimum impedance for bridged channels is 8 ms. Also, p se oh lea
observe t pr he oper speaker wiring when bridging channels. Input selection and
volume settings for br idged channels will be controlled by the left channel. ā€œBRā€ is
bridged mode and ā€œSTā€ is non-bridged or stereo mode.
7.
Input Selection Switch
Each channel is capable of delivering the source from many inputs. The three main
inputs are BUS 1, BUS 2 and LINE IN. The selection for these inputs is done via the
Input Selection switch associated with each channel. Select the desired source input.
Set the Input Selection switch to BUS 1 (will play source connected to the BUS 1
input), BUS 2 (will play source connected to the BUS 2 input) or LINE IN (will play
source connected to that channelā€™s LINE IN).
Speaker Output Terminals
The AMP1200VS uses high quality Phoenix style connectors for the speaker
connections. Use 14-18 gauge stranded two-conductor loudspeaker wire. Ensure that
at least 2 inches of each conductor are separated. Strip away Ā¼ inch of insulation
from each conductor. Connect the appropriate conductor to each screw terminal,
observing correct polarity. Also, please observe proper speaker wiring when bridging
channels.
Individual Channel Input
All twelve channels have their own dedicated input that allows the connection of
audio sources in addition to the common BUS inputs. This is useful when using the
AMP1200VS with an audio matrix switcher.
AC Voltage Switch
The unit is set at the factory for 115V U.S. operation; simply connect the included IEC
power cord to your wall outlet. F or 230V ope ation,r move the voltage selector s witch to
the 230V position. When operating at 230V the internal fuse located in the IEC
so et should also be changed. In most 230V applications a separate power cord will ck
be required and is not included.
IEC Power Connector
The unit comes with an IEC jack that permits removal of the AC power cord. This
allows the flexibility of changing the power cord for different countries. The IEC so et ck
also houses the main fuse holder. Plug the power cord supplied with the ampliļ¬er into
the ampliļ¬er and a wall outlet or appropriate surge protector.
CAUTION: DO NOT plug the ampliļ¬erā€™s power cord into a switched outlet, such as
what is provided on some Surround Receivers. If you wish to have the ampliļ¬er turn
on when the Receiver is powered up, use one of the power modes, such as Trigger or
Auto.
12.