Argo Dry nature 17 Handleiding

Argo Ontvochtiger Dry nature 17

Lees hieronder de 📖 handleiding in het Nederlandse voor Argo Dry nature 17 (14 pagina's) in de categorie Ontvochtiger. Deze handleiding was nuttig voor 71 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/14
15 V 04/20
DEHUMIDIFIER
DRY NATURE 17
DRY NATURE 21
OPERATING INSTRUCTIONS
Read the instructions carefully before operating or servicing the dehumidifier.
Observe all the safety instructions; failure to observe the instructions may lead to accidents and/or damage. Keep
these instructions in a safe place for future reference.
EN
16 V 04/20
The Refrigerant R290
ï‚· To realize the function of the air conditioner unit, a special refrigerant circulates in the
system. The refrigerant is the fluoride R290 = 3 GWP (Global warming potential). This
refrigerant is flammable and inodorous. It can lead to explosions under certain
conditions, however the flammability of this refrigerant is very low and it can be ignited
only by fire.
ï‚· Compared to other common luting refrigerant with no refrigerants, R290 is a non-pol
harm to the ozonosphere and a no effect upon the greenhouse effect. R290 has very
good thermodynamic features which lead to a really high energy efficiency. The units
therefore need less filling.
Warning:
Do not try to accelerate the defrosting process or to clean the appliance in different ways other
than those recommended by the manufacturer. Should repair be necessary, contact your
nearest authorized Argoclima Service Centre. Any repairs carried out by unqualified personnel
may be dangerous. The appliance has to be stored in a room that doesn’t have any
continuously operating ignition sources. (for example: open flames, an operating gas
appliance or an operating electric heater.) Do not pierce or burn.
Appliance has to be installed, operated and stored in a room with a floor area larger than 4 m 2.
For repairs, strictly follow manufacturer’s instructions only for appliances filled with R290
flammable gas. Be aware that refrigerants do not have any odour.
Appliance filled with flammable gas R290.
Before installing and using the appliance, read the owner’s manual.
Before repairing the appliance, read the service manual.
17 V 04/20
GENERAL OPERATING AND SAFETY INSTRUCTIONS
ï‚· This appliance is a very effective dehumidifier designed only
for domestic use!
ï‚· Do not place the appliance in humid environments such as
laundries.
ï‚· Do not place the unit near appliances which can generate heat or
near dangerous/inflammable materials.
ï‚· Only use this dehumidifier as described in this manual. Any other
use not recommended by the producer could cause fires, electric
shocks or malfunction.
ï‚· The unit must be placed in vertical position because it contains
refrigerant.
ï‚· After opening the unit packing for the first time, place the
appliance in vertical position to allow to the refrigerant to stabilize
and wait for two hours before to use it.
ï‚· Ensure that the required voltage and frequency (220-240 V/50 Hz)
match the available power source.
ï‚· This appliance can be used by children aged from 8 years and
above and people with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have been
given supervision or instruction concerning use of the appliance in
a safe way and understand the hazards involved.
ï‚· Children shall not play with the appliance.
ï‚· Cleaning and user maintenance shall not be made by children
without supervision.
ï‚· Make sure that the electric plug is secutely inserted. Do not use
multiple adapters. Do not touch the plug with wet hands. Ensure
that the plug is clean.
ï‚· Children between 3 and 8 years of age must only be able to turn
on/off the appliance, provided that it has been placed in its normal
operating position, and that they have been instructed on how to
safely use the appliance and that they have understood the risks.
ï‚· Children between 3 and 8 years of age must not be able to
connect the plug, regulate operation or clean the appliance or
carry out maintenance on it.
ï‚· Disconnect the power plus from the main power supply if it is
not used or during cleaning. An inserted power plug may
cause electric shock or accident.


Product specificaties

Merk: Argo
Categorie: Ontvochtiger
Model: Dry nature 17
Kleur van het product: Wit
Ingebouwd display: Ja
Gewicht: 13000 g
Breedte: 342 mm
Diepte: 234 mm
Hoogte: 560 mm
Geluidsniveau: 47 dB
Aan/uitschakelaar: Ja
Capaciteit watertank: 3.8 l
Geschikt voor ruimtes tot: 20 m²
Geïntegreerde timer: Ja
Koelend medium: R290
Certificering: CE
Luchtstroom: 250 m³/uur
AC-ingangsspanning: 220 - 240 V
AC-ingangsfrequentie: 50 Hz
Stroomverbruik (typisch): 260 W
Bedrijfstemperatuur (T-T): 5 - 35 °C
Relatieve vochtigheid in bedrijf (V-V): 40 - 80 procent
Indicator watertank vol: Ja
Zwenkwieltjes: Ja
Geschikt voor ruimtevolume tot: - m³
Humidistaat: Ja
Ontvochtigingscapaciteit (max): 17 l/24u
Automatische ontdooiing: Ja

Heb je hulp nodig?

Als je hulp nodig hebt met Argo Dry nature 17 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Ontvochtiger Argo

Handleiding Ontvochtiger

Nieuwste handleidingen voor Ontvochtiger