Apc XB005XPDR Handleiding
Lees hieronder de 📖 handleiding in het Nederlandse voor Apc XB005XPDR (2 pagina's) in de categorie UPS. Deze handleiding was nuttig voor 81 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/2
Safety and General Instructions
SAVE THESE INSTRUCTIONS - This manual contains important instructions that should
be followed during installation and maintenance of the product.
Read the user documentation to become familiar with the equipment before
trying to install or operate it.
• While disconnecting wires, be sure to disconnect the wires at battery pack(s) first and
then at the power supply unit.
• Always connect the wires to the power supply unit first and then to battery pack(s).
• Use RED color wire for +ve and BLACK color wire for –ve connections.
• Use insulated pin type lugs to be sure that the wire strands do not touch any metallic
surface during connection/disconnection.
• Be sure that the wires do not touch any metallic surface during
connection/disconnection.
• Allow minimum space of 50 mm above the battery pack and 180 mm below the battery
pack and 10 mm lateral distance from other devices to be sure of sufficient cooling.
• CAUTION: The enclosure can reach temperatures that exceed the burn thresholds for
touchable surfaces, depending on the ambient temperature and load.
• Do not introduce any objects into the device.
Specifications
Environmental
Physical
Battery
Certification and Standards
IEC/EN/BS/UL 62368-1, CSA-C22.2 No. 62368-1, IEC/EN 60950-1, CE, UKCA, cTUVus
Front Panel Features
Installation
Mounting
NOTE: Be sure that the input/output terminal blocks are at the top while mounting the
power supply unit on a 35 mm DIN rail.
1. Locate the top hooks of the rail
mounting system (on the battery
pack) with the unit slightly tilted
upwards.
2. Rotate the unit in clockwise
direction till the latch of the rail
mount system snaps on to the
DIN rail and the battery pack
cannot be rotated any further.
3. Shake the battery pack slightly
to be sure that it is securely
mounted on the DIN rail.
Dismounting
1. Release the latch of the rail
mount system (on the battery
pack) by pulling it downwards
using a screw driver.
2. Tilt the battery pack upwards till
the latch is free from the DIN
rail.
3. Slide the battery upwards till the
top hooks gets free from the
DIN rail.
Connect Battery Pack to the power supply unit
Recommended wire sizes and tightening torque
NOTE:
• Be sure to use a Pin Type cable lug for connecting the Input,
Output and Battery wires.
• To be sure of a secure connection, the wire insulation should be
stripped (S) for approx. 6 mm,
Be sure that all the strands are completely enclosed in the lug.
• Be sure to connect the wires first to the terminals on the power
supply unit and then to the terminals on the battery pack(s).
• Be sure that the positive and negative polarity wires are connected to the respective
output terminals on the power supply unit.
Connect a single battery pack
Connect the battery wires to the battery terminals (refer “Front Panel Features” for details).
Connect mutiple battery packs
Connect the battery wires to the battery terminals (refer “Front Panel Features” for details).
Ambient temperature Operating –15 to +50 °C
Storage* –15 to +40 °C
Humidity 0 to 95% (Non condensing)
Altitude 3000 m (Max.)
NOTE: * Charge the battery once in every 3 months during storage or
when not in use.
Dimensions without packaging (H x W x D) 192 x 129 x 119 mm
(7.56 x 5.08 x 4.69 in)
Dimensions with packaging (H x W x D) 240 x 190 x 188 mm
(9.45 x 7.48 x 7.40 in)
Weight without packaging 4.5 kg
(9.92 lb)
Weight with packaging 4.8 kg
(10.58 lb)
Model XB005XPDR
Type SMF VRLA
Nominal Voltage 24 VDC (2 Nos. 12 V batteries connected in series)
Capacity 4.5 Ah
Over current / Short circuit protection 40 A Fuses
Charging Voltage 27.4 VDC
Charging Current 0.75 A
Maximum number of battery packs
that can be connected in parallel 4
Battery Runtime 10 minutes at 10 A load
3 minutes at 20 A load
(+) Battery terminal
(–) Battery terminal
oem0348a
oem0349a
oem0350a
CAUTION
RISK OF EQUIPMENT DAMAGE
• Wiring should be performed by a qualified electrician.
• Wire size must comply with required current capacity as well as national and local
electrical codes.
• Be sure to turn Off the input power supply before connecting or disconnecting input,
output and battery wires to the terminals.
• Be sure that the wires do not touch each other or any metal object during connection/
disconnection.
• Be sure to connect the battery wires first to the power supply unit and then to the
battery.
• Be sure to disconnect wires first from the battery and then from the power supply unit.
• Be sure to crimp pin type lugs to the input, output and battery wires to prevent loose
strands from touching any metal object.
Failure to follow these instructions can result in equipment damage and
minor or moderate injury.
Wire Size Torque
Battery 12 AWG (3.310 mm2)0.8 N m
s
+–+–
+–
oem0351a
BP#1 BP#2
+–
+–+–+–
oem0352a
User Manual Easy UPS DIN Rail
Mount External Battery Pack
XB005XPDR
Customer support and warranty information is available at www.se.com.
© 2022 Schneider Electric. All rights reserved. Schneider Electric,
the Schneider Electric logo, are trademarks of Schneider Electric SE, its
subsidiaries or affiliated companies. All other brands may be trademarks of
their respective owners.
990-6464C
05/2022
Fuse Replacement
NOTE: Fuse replacement feature is available in battery packs manufactured after
June 2022.
Limited Factory Warranty
Schneider Electric IT Corporation (SEIT), warrants its products to be free from defects in
materials and workmanship for a period of ONE (1) year. The SEIT obligation under this
warranty is limited to repairing or replacing, at its own sole option, any such defective
products. Repair or replacement of a defective product or part thereof does not extend the
original warranty period.
This warranty applies only to the original purchaser who must have properly registered the
product within 10 days of purchase. Products may be registered online at
warranty.apc.com.
SEIT shall not be liable under the warranty if its testing and examination disclose that the
alleged defect in the product does not exist or was caused by end user or any third person
misuse, negligence, improper installation, testing, operation or use of the product contrary
to SEIT recommendations of specifications. Further, SEIT shall not be liable for defects
resulting from: 1) unauthorized attempts to repair or modify the product, 2) incorrect or
inadequate electrical voltage or connection, 3) inappropriate on site operation conditions,
4) Acts of God, 5) exposure to the elements, or 6) theft. In no event shall SEIT have any
liability under this warranty for any product where the serial number has been altered,
defaced, or removed.
EXCEPT AS SET FORTH ABOVE, THERE ARE NO WARRANTIES, EXPRESS OR
IMPLIED, BY OPERATION OF LAW OR OTHERWISE, APPLICABLE TO PRODUCTS
SOLD, SERVICED OR FURNISHED UNDER THIS AGREEMENT OR IN CONNECTION
HEREWITH.
SEIT DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY,
SATISFACTION AND FITNESS FOR A PARTICULAR PURPOSE.
SEIT EXPRESS WARRANTIES WILL NOT BE ENLARGED, DIMINISHED, OR
AFFECTED BY AND NO OBLIGATION OR LIABILITY WILL ARISE OUT OF, SEIT
RENDERING OF TECHNICAL OR OTHER ADVICE OR SERVICE IN CONNECTION
WITH THE PRODUCTS.
THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND IN LIEU OF
ALL OTHER WARRANTIES AND REMEDIES. THE WARRANTIES SET FORTH ABOVE
CONSTITUTE SEIT'S SOLE LIABILITY AND PURCHASER EXCLUSIVE REMEDY FOR
ANY BREACH OF SUCH WARRANTIES. SEIT WARRANTIES EXTEND ONLY TO
ORIGINAL PURCHASER AND ARE NOT EXTENDED TO ANY THIRD PARTIES.
IN NO EVENT SHALL SEIT, ITS OFFICERS, DIRECTORS, AFFILIATES OR
EMPLOYEES BE LIABLE FOR ANY FORM OF INDIRECT, SPECIAL,
CONSEQUENTIAL OR PUNITIVE DAMAGES, ARISING OUT OF THE USE, SERVICE
OR INSTALLATION OF THE PRODUCTS, WHETHER SUCH DAMAGES ARISE IN
CONTRACT OR TORT, IRRESPECTIVE OF FAULT, NEGLIGENCE OR STRICT
LIABILITY OR WHETHER SEIT HAS BEEN ADVISED IN ADVANCE OF THE
POSSIBILITY OF SUCH DAMAGES. SPECIFICALLY, SEIT IS NOT LIABLE FOR ANY
COSTS, SUCH AS LOST PROFITS OR REVENUE, WHETHER DIRECT OR INDIRECT,
LOSS OF EQUIPMENT, LOSS OF USE OF EQUIPMENT, LOSS OF SOFTWARE, LOSS
OF DATA, COSTS OF SUBSTITUANTS, CLAIMS BY THIRD PARTIES, OR
OTHERWISE.
NOTHING IN THIS LIMITED WARRANTY SHALL SEEK TO EXCLUDE OR LIMIT OR
DEATH OR PERSONAL INJURY RESULTING FROM ITS NEGLIGENCE OR ITS
FRAUDULENT MISREPRESENTATION OF TO THE EXTENT THAT IT CANNOT BE
EXCLUDED OR LIMITED BY APPLICABLE LAW.
To obtain service under warranty you must obtain a Returned Material Authorization (RMA)
number from customer support. Customers with warranty claims issues may access the
SEIT worldwide customer support network through the APC by Schneider Electric Web
site: www.apc.com. Select your country from the country selection drop down menu. Open
the Support tab at the top of the web page to obtain information for customer support in
your region. Products must be returned with transportation charges prepaid and must be
accompanied by a brief description of the problem encountered and proof of date and place
of purchase.
Schneider Electric Worldwide
Customer Support
Customer support for this or any other Schneider Electric product is available at no charge
in any of the following ways:
• Visit the Schneider Electric Web site to access documents in the Schneider Electric
Knowledge Base and to
– submit customer support requests.
– www.schneider-electric.com (Corporate Headquarters)
Connect to localized Schneider Electric Web sites for specific countries, each of which
provides customer support information.
– www.schneider-electric.com/support/
Global support searching Schneider Electric Knowledge Base and using e-support.
• Contact Schneider Electric IT (SEIT) Customer Support Center by telephone or
e-mail.
– Local, country specific centers: go to www.schneider-electric.com/support/contact
for contact information.
For information on how to obtain local customer support, contact the Schneider Electric
representative or other distributor from whom you purchased your Schneider Electric
product.
a. Disconnect all the wires from the battery pack.
b. Dismount the battery pack from the DIN rail. Refer to “Dismounting” on page 1 for
details.
a. Turn the battery pack upside down.
b. Locate the 3 screws securing the
cover to the chassis and unfasten
them.
Locate the 4 screws securing the cover
to the chassis and unfasten them.
Remove the cover. Pull out the fuses from the holders.
Push in the replacement fused into the
holders.
Replace the cover.
Secure the cover to the chassis by
fastening the 4 screws (unfastened in
step ).
a. Turn the battery pack upside down.
b. Secure the cover to the chassis by
fastening the 3 screws (unfastened
in step ).
a. Mount the battery pack on the DIN rail. Refer to “Mounting” on page 1 for details.
b. Connect all the wires to the battery pack (disconnected in step
).
3x
oem
03a
8
0
4x
oem037 9a
oem
03a
81
oem0
3a
82
oe
m03a
83
oem03a
8
4
4x
oem
03a
85
3x
oem
03a
86
Product specificaties
Merk: | Apc |
Categorie: | UPS |
Model: | XB005XPDR |
Kleur van het product: | Grijs |
Gewicht: | 4500 g |
Breedte: | 192 mm |
Diepte: | 119 mm |
Hoogte: | 129 mm |
Accu/Batterij voltage: | 24 V |
Batterij capaciteit: | 4.5 Ah |
Batterijtechnologie: | Sealed Lead Acid (VRLA) |
Code geharmoniseerd systeem (HS): | 85044090 |
Heb je hulp nodig?
Als je hulp nodig hebt met Apc XB005XPDR stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding UPS Apc
16 November 2024
12 November 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
Handleiding UPS
- UPS HP
- UPS IKEA
- UPS AEG
- UPS Siemens
- UPS Dell
- UPS Digitus
- UPS Eaton
- UPS Emerson
- UPS Furman
- UPS Gembird
- UPS Gys
- UPS Lenovo
- UPS LevelOne
- UPS Riello
- UPS Schneider
- UPS Voltcraft
- UPS Jung
- UPS Steren
- UPS Conceptronic
- UPS Tripp Lite
- UPS Approx
- UPS Block
- UPS LC-Power
- UPS Energenie
- UPS CyberPower
- UPS Adj
- UPS East
- UPS Equip
- UPS Liebert
- UPS Avocent
- UPS Minute Man
- UPS Minuteman
- UPS Maruson
- UPS V7
- UPS Phoenix Contact
- UPS Puls Dimension
- UPS Vanson
- UPS Salicru
- UPS SurgeX
- UPS Murr Elektronik
- UPS Altronix
- UPS Ditek
- UPS Bxterra
- UPS Middle Atlantic
- UPS FSP
- UPS Atlantis Land
- UPS PowerWalker
- UPS FSP/Fortron
- UPS Online USV
Nieuwste handleidingen voor UPS
18 November 2024
17 November 2024
17 November 2024
17 November 2024
15 November 2024
15 November 2024
14 November 2024
14 November 2024
7 November 2024
7 November 2024