Apc SURT1000XLI+SURTRK Handleiding

Apc UPS SURT1000XLI+SURTRK

Lees hieronder de 📖 handleiding in het Nederlandse voor Apc SURT1000XLI+SURTRK (12 pagina's) in de categorie UPS. Deze handleiding was nuttig voor 25 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/12
990-1083A, 01/03
APC Smart-UPS® RT
External Battery Pack
For Use With Models SURT1000XLI and SURT2000XLI
Tower/Rack Mount Convertible
User’s Manual
English
1
1: SAFETY INFORMATION
American Power Conversion Corporation (APC) is the leading national and international manufac-
turer of state-of-the-art uninterruptible power supplies, redundant switches, power management soft-
ware, and related equipment. APC products protect hardware, software, and data from the threat of
power disturbances in business and government offices throughout the world.
The APC Smart-UPS RT External Battery Pack connects to an APC Uninterruptible Power Supply
(UPS) and provides extended protection from electrical blackouts, brownouts, sags, and surges.
Changes or modifications to this unit not expressly approved by the party respon-
sible for compliance could void the warranty.
H S ANDLING AFETY
Be careful. Do not lift heavy loads without assistance.
<18 kg (<40 lb) 32–55 kg (70–120 lb)
18–32 kg (40–70 lb) >55 kg (>120 lb)
This equipment is intended for installation in a temperature-controlled indoor area free of conductive
contaminants. Refer to Specifications at the APC web site for the actual temperature range.
LIFE SUPPORT APPLICATION POLICY
As a general policy, APC does not recommend the use of any of its products in life support applica-
tions where failure or malfunctions of the APC product can be reasonably expected to cause failure
of the life support device or to significantly affect its safety or effectiveness. APC does not recom-
mend the use of any of its products in direct patient care. APC will not knowingly sell its products
for use in such applications unless it receives in writing assurances satisfactory to APC that (a) the
risks of injury or damage have been minimized, (b) the customer assumes all such risks, and (c) the
liability of APC is adequately protected under the circumstances.
Examples of devices considered to be life support devices are neonatal oxygen and analyzers, nerve
stimulators (whether used for anesthesia, pain relief, or other purposes), autotransfusion devices,
blood pumps, defibrillators, arrhythmia detectors and alarms, pacemakers, hemodialysis systems,
peritoneal dialysis systems, neonatal ventilator incubators, ventilators for both adults and infants,
anesthesia ventilators, infusion pumps, and any other device designated as “critical” by the
U.S.F.D.A.
Hospital grade wiring devices and leakage current may be ordered as options on many APC UPS
systems, APC does not claim that units with this modification are certified or listed as Hospital
Grade by APC or any other organization. Therefore these units do not meet the requirements for use
in direct patient care.


Product specificaties

Merk: Apc
Categorie: UPS
Model: SURT1000XLI+SURTRK
Kleur van het product: Zwart
Gewicht: 23000 g
Breedte: 85 mm
Diepte: 483 mm
Hoogte: 432 mm
Gewicht verpakking: 27800 g
LED-indicatoren: Power,Status
Vormfactor: Rackmontage
Ingebouwde ventilator: Ja
Afmetingen verpakking (BxDxH): 630 x 594 x 286 mm
RS-232 port: 1
Geluidsalarm(en): Ja
Duurzaamheidscertificaten: RoHS
Uitgangsvermogen: 700 W
Accu/Batterij oplaadtijd: 3 uur
Temperatuur bij opslag: -20 - 50 °C
Stroomspanning bescherming: Overbelasting
Frequentie: 50/60 Hz
Luchtvochtigheid bij opslag: 0 - 95 procent
Hoogte, in bedrijf: 0 - 3000 m
Hoogte bij opslag: 0 - 15000 m
Type koeling: Actief
Stekker: C14 stekker
Efficientie: 88 procent
Rackcapaciteit: 2U
Relatieve vochtigheid in bedrijf (V-V): 0 - 95 procent
Batterijtechnologie: Sealed Lead Acid (VRLA)
Surge energy rating: 420 J
Aantal AC uitgangen: 8 AC-uitgang(en)
Stopcontacttypes: C13 stekker
Aantal fases: 9
Output power capacity: 1 kVA
Ingang operation voltage (min): 100 V
Ingang operation voltage (max): 280 V
Uitgang operation voltage (min): 220 V
Uitgang operation voltage (max): 240 V
Crest factor: 3:1
Aantal input fases: 8
Typische backup tijd op halve lading: 8 min
Typische backup tijd op volledige lading: 1000 min
Aantal output fases: 1
EMI/RFI geluidsfiltering: Ja
Spanningsbeveiliging: Ja
EMI/RFI ruisverzwakking: 50 dB
Number of output IEC jumpers: 2