Documentation Supplement for
Marine Smart-UPSâ„¢
SRT5KRMXLIM, SRT6KRMXLIM
External Battery Pack
SRT192RMBPM
Product Description
The information in this documentation supplement applies to specific APCâ„¢ by Schneider Electric DNV-GL
Type Approved Uninterruptible Power Supply (UPS) models, external battery packs (XLBP), companion EMI
filters and the tower installation kit.
The tower installation kit is used only for UPS models in tower configurations.
The APC by Schneider Electric products listed in the table below meet DNV-GL Type Approval 2.4 requirements.
When these specified UPS models are used with the appropriate companion filter and tower installation kit they
are approved for use on the bridge, in control rooms and in accommodation zones.
SKU Description
SRT5KRMXLIM Marine Smart-UPS SRT 5000 VA, 230 Vac, Rack-Mount
SRT6KRMXLIM Marine Smart-UPS SRT 6000 VA, 230 Vac, Rack-Mount
SRT6M Marine Filter for use with Smart-UPS UPS models:
SRT5KRMXLIM/SRT6KRMXLIM
SRT10BDVK Marine Secure Bolt Down Vibration Isolation kit for Smart-UPS
UPS models:
SRT5KRMXLIM,SRT6KRMXLIM
XBP model:
SRT192RMBPM
SRT192RMBPM Marine external battery pack for use with Smart-UPS models:
SRT5KRMXLIM, SRT6KRMXLIM
SRT10IP23 SRT10IP23 enclosure for use with Smart-UPS models SRT5KRMXLIM,
SRT6KRMXLIM
Documentation Supplement2
Specifications
When the APC by Schneider Electric Marine UPS models listed in the table on the previous page are used with the
appropriate companion filter, the specifications in this marine application supplement supersede the specifications
listed in the UPS user manual supplied in the carton with the SRT products.
The APC by Schneider Electric Marine UPS and XLBP models listed in the table on the previous page, are capable of
operating at temperatures up to 55º C for up to 16 hours in a 24 hour period. This meets the DNV-GL Type Approval
2.4 temperature Class A requirements.
Operation at a temperature above 40º C requires the UPS power output to be de-rated.
• 0º C to 40º C (32º F to 104º F) at 100% rated output power
• 40º C to 55º C (104º F to 131º F) de-rate output power 2.5%/º C (1.38%/º F)
The UPS and XBP models are capable of operating at elevated temperatures.
However, expected battery life drops by 50% for every 10º increase in ambient temperatures
above 25º C (77º F).
For maximum runtime capability avoid operating the UPS and XBP models at temperatures
above 40º C (104º F).
Certifications
CE
GS
EAC
RCM
DNV-GL
For DNV-GL Type Approval certificate go to the APC web site, www.apc.com.
IEC 60945 recommended compass distances
Input Voltage Range (Full Load, t=40º C) 160 V to 280 V
Input Voltage Range (Half Load, t=40º C) 100 V to 280 V
Input Voltage Range (Full Load, t=55º C) 180 V to 280 V
Input Voltage Range (Half Load, t=55º C) 112.5 V to 280 V
SRT5KRMXLIM 258 cm
SRT6KRMXLIM 247 cm
Documentation Supplement 3
Installation
For rack-mount installation instructions refer to the UPS or XLBP installation guide supplied with this XLBP.
Tower Configuration
For shipboard tower installation, APC by Schneider Electric offers a secure bolt down vibration isolation kit,
SRT10BDVK.
The installation guide is supplied in the carton with the SRT10BDVK kit.
The installation guide is also available;
~on the APC web site www.apc.com
~on the Documentation CD supplied in the carton with the SRT10BDVK kit.
SRT5KRMXLIM +
SRT6M + SRT10BDVK
SRT6KRMXLIM +
SRT6M + SRT10BDVK
SRT192RMBPM +
SRT10BDVK
Product specificaties
Merk: | Apc |
Categorie: | UPS |
Model: | Marine SRT192RMBPM |
Heb je hulp nodig?
Als je hulp nodig hebt met Apc Marine SRT192RMBPM stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding UPS Apc
2 December 2024
2 December 2024
2 December 2024
2 December 2024
16 November 2024
12 November 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
Handleiding UPS
- UPS HP
- UPS IKEA
- UPS AEG
- UPS Siemens
- UPS Dell
- UPS Digitus
- UPS Eaton
- UPS Emerson
- UPS Furman
- UPS Gembird
- UPS Gys
- UPS Lenovo
- UPS LevelOne
- UPS Riello
- UPS Schneider
- UPS Voltcraft
- UPS Jung
- UPS Steren
- UPS Conceptronic
- UPS Tripp Lite
- UPS Approx
- UPS Block
- UPS LC-Power
- UPS Energenie
- UPS CyberPower
- UPS Adj
- UPS East
- UPS Equip
- UPS Liebert
- UPS Avocent
- UPS Minute Man
- UPS Minuteman
- UPS Maruson
- UPS V7
- UPS Phoenix Contact
- UPS Puls Dimension
- UPS Vanson
- UPS Salicru
- UPS SurgeX
- UPS Murr Elektronik
- UPS Altronix
- UPS Ditek
- UPS Bxterra
- UPS Middle Atlantic
- UPS FSP
- UPS Atlantis Land
- UPS PowerWalker
- UPS FSP/Fortron
- UPS Online USV
Nieuwste handleidingen voor UPS
14 December 2024
14 December 2024
10 December 2024
10 December 2024
8 December 2024
8 December 2024
18 November 2024
17 November 2024
17 November 2024
17 November 2024