Apc BVS240XDPDR Handleiding

Apc UPS BVS240XDPDR

Lees hieronder de 📖 handleiding in het Nederlandse voor Apc BVS240XDPDR (2 pagina's) in de categorie UPS. Deze handleiding was nuttig voor 8 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/2
Safety and General Instructions
SAVE THESE INSTRUCTIONS - This manual contains important instructions that should
be followed during installation and maintenance of the product.
Read the user documentation to become familiar with the equipment before
trying to install or operate it.
Switch off the input power before connecting or disconnecting the wires.
Use RED color wire for +ve and BLACK color wire for ve connections.
Use insulated pin type lugs to be sure that the wire strands do not touch any metallic
surface during connection/disconnection.
Be sure that the wires do not touch any metallic surface during connection/
disconnection.
Be sure to connect the wires to the power supply unit first and then to battery pack(s).
While disconnecting wires, be sure to disconnect the wires at battery pack(s) first and
then at the power supply unit.
Allow a minimum space of 50 mm above the unit, 180 mm below the unit and 10 mm
lateral distance from other devices to be sure of sufficient cooling.
CAUTION: The enclosure can reach temperatures that exceed the burn thresholds for
touchable surfaces, depending on the ambient temperature and load.
Do not introduce any objects into the power supply unit.
Specifications
Environmental
Physical
Input
Output
Certification and Standards
IEC/EN/BS/UL 62368-1, CSA-C22.2 No. 62368-1, IEC/EN 60950-1, UL 508,
CSA C22.2 No. 14, IEC/EN 61010-1.
cTUVus CE, UKCA, GB 4943.1, CQC, EN 55032, EN55035, EN IEC 61000-6-2,
EN IEC 61000-6-4, EN IEC 61204-3, FCC 47 CFR Part 15, Subpart B & ICES-003 Issue 7
Front Panel Features
Installation
Mounting
NOTE: Be sure that the input/output terminal block is at the bottom while mounting the
power supply unit on a 35 mm DIN rail.
1. Locate the top hook of the rail
mounting system (on the unit)
with the unit slightly tilted
upwards.
2. Rotate the unit in clockwise
direction till the latch of the rail
mount system snaps on to the
DIN rail and the unit cannot be
rotated any further.
3. Shake the unit slightly to be
sure that it is securely mounted
on the DIN rail.
Dismounting
1. Release the latch of the rail
mount system (on the unit) by
pulling it downwards using a
screw driver.
2. Tilt the unit upwards till the latch
is free from the DIN rail.
3. Slide the unit upwards till the
top hook gets free from the DIN
rail.
Dry contact details
All dry contacts (Pin3 to Pin10) are normally closed during operation and will open during
an event.
NOTE:
NC = Normally Closed; NO = Normally Open; NA = Not Applicable.
To insert wires into the Dry Contact terminals, press the locking lever (
) using a
suitable screwdriver and insert the wire into the terminal (). Remove the screwdriver
to secure the wire to the terminal.
Ambient temperature Operating –15 to +50 °C
Storage –15 to +70 °C
Humidity 5 to 95% (Non condensing)
Altitude Operating 3000 m (Max.)
Storage 3000 m (Max.)
Audible Noise < 40 db
International Protection Code IP 20
Operating Protection Class Class II
Dimensions without packaging (H x W x D) 129 x 40 x 119 mm
(5.08 x 1.57 x 4.69 in)
Dimensions with packaging (H x W x D) 190 x 57x 188 mm
(7.47 x 2.23 x 7.39 in)
Weight without packaging 0.5 kg
(1.1 lb)
Weight with packaging 0.7 kg
(1.54 lb)
240 W 480 W
Model BVS240XDPDR BVS480XDPDR
Nominal input voltage 24 VDC
Voltage Range 21.6 – 28.6 VDC
Nominal Current 10 A 20 A
Runtime at full load (with 1 battery pack) 10 min at 10 A load 3 min at 20 A load
Efficiency at Nominal Voltage (Bypass mode,
battery fully charged) >95%
Over current / Short circuit protection 40 A Fuse
240 W 480 W
Nominal output voltage UN / tolerance 24 VDC
Switch On time (On delay time typical) < 1 s
Output current 10 A 20 A
Output over current limit 10.5 A< OCP<13 A 20.5 A<OCP<26 A
Short circuit protection Yes
Over temperature protection Yes
No. of units series connection No
No. of units parallel connection No
(+) Battery terminal
(–) Battery terminal
(–) Output terminal
(+) Output terminal
(–) Input terminal
(+) Input terminal
Dry contact terminals
Status LED - Red
Status LED - Green
240 W 480 W
oem0343a
Pin1 Remote On/Off. Connect Normally Open
Push to On button to this contact.
Pin2
Pin3 On-Battery mode
Pin4
Pin5 Replace battery
Pin6
Pin7 Battery disconnected
Pin8
Pin9 Low battery
Pin10
Locking lever
Terminal
Mode of Operation Line
Mode
Battery
Mode
Battery Mode
Low Battery
Line Mode
Battery disconnected
Replace
Battery
Condition
Remote On/Off NA NA NA NA NA
On-Battery NC NO NO NC NC
Replace Battery NC NC NC NC NO
Battery Disconnected NC NC NC NO NC
Low Battery NC NC NO NC NC
oem0344a
oem
0345a
 
oem0346a
User Manual Easy UPS DIN Rail
Mount DC to DC Power Supply
BVS240XDPDR/BVS480XDPDR
Customer support and warranty information is available at www.se.com.
© 2022 Schneider Electric. All rights reserved. Schneider Electric,
the Schneider Electric logo, are trademarks of Schneider Electric SE, its
subsidiaries or affiliated companies. All other brands may be trademarks of
their respective owners.
990-6465B
03/2022
Connect Input, Output and Battery
Recommended wire sizes and tightening torque
NOTE:
Be sure to use a Pin Type cable lug for connecting the Input,
Output and Battery wires.
To be sure of a secure connection, the wire insulation should be
stripped (S) for approx. 6 mm,
Be sure that all the strands are completely enclosed in the lug.
Be sure that the positive and negative polarity wires are connected to the respective
terminals on the power supply unit and the battery pack.
1. Connect the DC Input wires to the input terminals (refer “Front Panel Features for
details).
2. Connect the output wires to the output terminals (referFront Panel Features for
details).
3. Connect the battery wires to the battery terminals (refer “Front Panel Features” for
details).
NOTE:
Be sure to connect the wires first to the terminals on the power supply unit and then to
the terminals on the battery pack(s).
A maximum of 4 battery packs can be connected to a power supply unit.
Start up
NOTE: Be sure that the load is connected to the UPS before turning On the DC input.
Turn On the DC to DC Power Supply in On-Line mode
The power supply unit turns on automatically when the DC input is applied to the input
terminals.
Turn On the DC to DC Power Supply in On-Battery mode
Press the REMOTE /ON OFF Push to On button, to turn on the power supply unit in On-
Battery mode.
Turn off the DC to DC Power Supply
To turn Off, press the REMOTE ON/OFF push button.
Status Indicators
Limited Factory Warranty
Schneider Electric IT Corporation (SEIT), warrants its products to be free from defects in
materials and workmanship for a period of TWO (2) years. The SEIT obligation under this
warranty is limited to repairing or replacing, at its own sole option, any such defective
products. Repair or replacement of a defective product or part thereof does not extend the
original warranty period.
This warranty applies only to the original purchaser who must have properly registered the
product within 10 days of purchase. Products may be registered online at
warranty.apc.com.
SEIT shall not be liable under the warranty if its testing and examination disclose that the
alleged defect in the product does not exist or was caused by end user or any third person
misuse, negligence, improper installation, testing, operation or use of the product contrary
to SEIT recommendations of specifications. Further, SEIT shall not be liable for defects
resulting from: 1) unauthorized attempts to repair or modify the product, 2) incorrect or
inadequate electrical voltage or connection, 3) inappropriate on site operation conditions,
4) Acts of God, 5) exposure to the elements, or 6) theft. In no event shall SEIT have any
liability under this warranty for any product where the serial number has been altered,
defaced, or removed.
EXCEPT AS SET FORTH ABOVE, THERE ARE NO WARRANTIES, EXPRESS OR
IMPLIED, BY OPERATION OF LAW OR OTHERWISE, APPLICABLE TO PRODUCTS
SOLD, SERVICED OR FURNISHED UNDER THIS AGREEMENT OR IN CONNECTION
HEREWITH.
SEIT DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY,
SATISFACTION AND FITNESS FOR A PARTICULAR PURPOSE.
SEIT EXPRESS WARRANTIES WILL NOT BE ENLARGED, DIMINISHED, OR
AFFECTED BY AND NO OBLIGATION OR LIABILITY WILL ARISE OUT OF, SEIT
RENDERING OF TECHNICAL OR OTHER ADVICE OR SERVICE IN CONNECTION
WITH THE PRODUCTS.
THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND IN LIEU OF
ALL OTHER WARRANTIES AND REMEDIES. THE WARRANTIES SET FORTH ABOVE
CONSTITUTE SEIT'S SOLE LIABILITY AND PURCHASER EXCLUSIVE REMEDY FOR
ANY BREACH OF SUCH WARRANTIES. SEIT WARRANTIES EXTEND ONLY TO
ORIGINAL PURCHASER AND ARE NOT EXTENDED TO ANY THIRD PARTIES.
IN NO EVENT SHALL SEIT, ITS OFFICERS, DIRECTORS, AFFILIATES OR
EMPLOYEES BE LIABLE FOR ANY FORM OF INDIRECT, SPECIAL,
CONSEQUENTIAL OR PUNITIVE DAMAGES, ARISING OUT OF THE USE, SERVICE
OR INSTALLATION OF THE PRODUCTS, WHETHER SUCH DAMAGES ARISE IN
CONTRACT OR TORT, IRRESPECTIVE OF FAULT, NEGLIGENCE OR STRICT
LIABILITY OR WHETHER SEIT HAS BEEN ADVISED IN ADVANCE OF THE
POSSIBILITY OF SUCH DAMAGES. SPECIFICALLY, SEIT IS NOT LIABLE FOR ANY
COSTS, SUCH AS LOST PROFITS OR REVENUE, WHETHER DIRECT OR INDIRECT,
LOSS OF EQUIPMENT, LOSS OF USE OF EQUIPMENT, LOSS OF SOFTWARE, LOSS
OF DATA, COSTS OF SUBSTITUANTS, CLAIMS BY THIRD PARTIES, OR
OTHERWISE.
NOTHING IN THIS LIMITED WARRANTY SHALL SEEK TO EXCLUDE OR LIMIT OR
DEATH OR PERSONAL INJURY RESULTING FROM ITS NEGLIGENCE OR ITS
FRAUDULENT MISREPRESENTATION OF TO THE EXTENT THAT IT CANNOT BE
EXCLUDED OR LIMITED BY APPLICABLE LAW.
To obtain service under warranty you must obtain a Returned Material Authorization (RMA)
number from customer support. Customers with warranty claims issues may access the
SEIT worldwide customer support network through the APC by Schneider Electric Web
site: www.apc.com. Select your country from the country selection drop down menu. Open
the Support tab at the top of the web page to obtain information for customer support in
your region. Products must be returned with transportation charges prepaid and must be
accompanied by a brief description of the problem encountered and proof of date and place
of purchase.
Schneider Electric Worldwide
Customer Support
Customer support for this or any other Schneider Electric product is available at no charge
in any of the following ways:
Visit the Schneider Electric Web site to access documents in the Schneider Electric
Knowledge Base and to
submit customer support requests.
www.schneider-electric.com (Corporate Headquarters)
Connect to localized Schneider Electric Web sites for specific countries, each of which
provides customer support information.
– www.schneider-electric.com/support/
Global support searching Schneider Electric Knowledge Base and using e-support.
Contact Schneider Electric IT (SEIT) Customer Support Center by telephone or
e-mail.
Local, country specific centers: go to www.schneider-electric.com/support/contact
for contact information.
For information on how to obtain local customer support, contact the Schneider Electric
representative or other distributor from whom you purchased your Schneider Electric
product.
CAUTION
RISK OF EQUIPMENT DAMAGE
Wiring should be performed by a qualified electrician.
Wire size must comply with required current capacity as well as national and local
electrical codes.
Be sure to turn Off the input power supply before connecting or disconnecting input,
output and battery wires to the terminals.
Be sure that the wires do not touch each other or any metal object during
connection/disconnection.
Be sure to connect the battery wires first to the power supply unit and then to the
battery.
Be sure to disconnect wires first from the battery and then from the power supply
unit.
Be sure to crimp pin type lugs to the input, output and battery wires to prevent loose
strands from touching any metal object.
Failure to follow these instructions can result in equipment damage and
minor or moderate injury.
Wire Size
Torque
240 W 480 W
Input/Output 16 AWG (1.307 mm2)12 AWG (3.310 mm2) 0.8 N m
Dry Contacts 26 AWG (0.128 mm2) Not Applicable
Remote On/Off
Battery 12 AWG (3.310 mm2)0.8 N m
Green LED Red LED UPS Status
Illuminated Power supply unit is in on-line mode and the
battery is charging/charged.
Flashes 1 sec on
and 1 sec off Power supply unit is in on-battery mode.
s
Flashes 0.3 sec on
and 0.3 sec off Low battery alert.
Flashes 1 sec on
and 1 sec off An over current event has occurred.
Illuminated Power supply unit has tripped due to an over
voltage event.
Flashes An over temperature event has occured.
Green LED Red LED UPS Status


Product specificaties

Merk: Apc
Categorie: UPS
Model: BVS240XDPDR
Kleur van het product: Grijs
Gewicht: 500 g
Breedte: 40 mm
Diepte: 129 mm
Hoogte: 119 mm
Uitgangsvermogen: 240 W
Code geharmoniseerd systeem (HS): 85078000
Output power capacity: 0.24 kVA
Ingang operation voltage (min): 21.6 V
Ingang operation voltage (max): 28.6 V
Uitgang operation voltage (min): 24 V
Uitgang operation voltage (max): 24 V

Heb je hulp nodig?

Als je hulp nodig hebt met Apc BVS240XDPDR stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding UPS Apc

Handleiding UPS

Nieuwste handleidingen voor UPS