Apc BR1500G-BR Handleiding
Lees hieronder de 📖 handleiding in het Nederlandse voor Apc BR1500G-BR (10 pagina's) in de categorie UPS. Deze handleiding was nuttig voor 48 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/10
Installation and Operation Manual
Back-UPS® BR1500G-BR
Connect the battery
Inventory Safety
This unit is intended for indoor use only.
Do not operate this unit in direct sunlight, in
contact with fluids, or where there is
excessive dust or humidity.
Do not block the air vents on this unit.
1 2 3
4 5 Charge the battery for at least 16
hours before use.
bu001a
bu055a
bu057a
bu059a
bu058a
bu060a
Back-UPS BR1500G-BR Installation and Operation2
PowerChute® Personal Edition Software
Overview
PowerChute Personal Edition Software allows you to use your computer to access additional power protection and
management features of the Back-UPS.
Using PowerChute, you can:
• Preserve work in progress during a power outage by putting your computer into Hibernate mode. When the
power returns, the computer will appear exactly as it did before the power outage.
• Configure the Back-UPS management features, such as power-saving outlets, shutdown parameters, audible
alarms, and more.
• Monitor and view the status of the Back-UPS, including the estimated runtime, power consumption, power
event history, and more.
Available features will vary by Back-UPS model and operating system.
If you choose not to install PowerChute, the Back-UPS will still provide backup power and power protection to
connected equipment. However, you will only be able to configure a limited number of features using the display
interface.
Compatibility
PowerChute is compatible with Windows operating systems only. For a detailed list of supported operating systems,
go to www.apc.com, select Software & Firmware.
For Mac operating systems, we recommend using the native shutdown application (within System Preferences)
which recognizes your battery backup and allows you to configure shutdown of your system during power outages.
To access this application, connect a USB cable from the Back-UPS DATA PORT (POWERCHUTE PORT) to a USB port
on your computer, and see the documentation provided with your computer.
Installation
Connect the Back-UPS to a computer using a USB cable. Plug one end into the on the rear panel P C OWER HUTE PORT
of the Back-UPS and the other into a USB port on your computer.
Insert the PowerChute CD into your computer and follow the on-screen instructions. If your
Back-UPS did not come with a PowerChute CD, download the software from www.apc.com, select Software &
Firmware.
Back-UPS BR1500G-BR Installation and Operation 3
Connect the equipment
Battery Backup and Surge Protected outlets
When the Back-UPS is receiving input power, the
Surge Protection only outlets and the Battery Backup
with Surge Protection outlets will supply power to
connected equipment. During a power outage or other
utility problems, only the Battery Backup outlets
receive power for a limited time from the Back-UPS.
Connect equipment such as printers, FAX machines,
scanners, or other peripherals that do not need battery
backup power to the Surge Protection Only outlets.
These outlets provide full time protection from surges
even if the Back-UPS is switched off.
Master and Controlled outlets
To conserve electricity, when the device connected to
the Master outlet goes into Sleep or Standby mode, or
turns off, the Controlled by Master device(s) will shut
down as well, saving electricity.
Connect a master device, such as a desktop computer
or audio/visual receiver to the Master outlet. Connect
peripheral devices such as a printer, speakers, or a
scanner to the Controlled by Master outlets.
1USB and Serial Data port
PowerChute port
To use PowerChute Personal Edition, connect the supplied USB software cable or serial cable
(not supplied).
2Ground screw Connect the ground wire from another surge suppression device such as a network or data line
surge protector to the ground screw on the Back-UPS.
3Building Wiring Fault LED When the LED illuminates, a building wiring fault has occurred. Contact a qualified electrician to
correct the fault.
4Surge Protection outlets,
Controlled by Master outlets
These outlets provide surge protection during a power outage. These outlets will disconnect from
AC power during a power outage, or in the event that the Master outlet goes into Sleep mode.
5Surge Protection outlets These outlets provide full-time surge protection, when the unit is turned on or off. Connect a
printer, scanner or other devices that do not require battery backup protection.
6AC Power Cable Connect the Back-UPS to utility power.
7Battery Backup outlets with
Surge Protection
During a power outage or other utility problems, these outlets provide power from the
Back-UPS battery. Connect critical equipment such as desktop computer, computer monitor,
modem or other data sensitive devices to these outlets.
8Battery Backup, Controlled by
Master outlet with Surge
Protection
During a power outage or other utility problems, these outlets provide power from the
Back-UPS battery.
These outlets will disconnect from AC power during a power outage, or in the event that the
Master outlet goes into Sleep mode.
Connect critical equipment such as desktop computer, computer monitor, modem or other data
sensitive devices to these outlets.
9Master outlet Connect the master device to this outlet, in most scenarios, this will be the main computer.
:Gigabit Ethernet
surge-protected ports
Use an Ethernet cable to connect a modem to the IN port, and a computer to the OUT port.
;External Battery Pack connector Connect an external battery pack to provide additional battery backup runtime.
<Coaxial ports with
Surge Protection
Connect a modem or other devices with coaxial connectors to the coaxial ports.
bu220a
Battery
Backup
Surge
Only
Circuit Breaker
Push to Reset
BR1500G-BR
PowerChute
Port
USB & Serial
Cable In
Cable out
Product specificaties
Merk: | Apc |
Categorie: | UPS |
Model: | BR1500G-BR |
Kleur van het product: | Zwart |
Gewicht: | 13000 g |
Breedte: | 112 mm |
Diepte: | 382 mm |
Hoogte: | 301 mm |
Snoerlengte: | 1.83 m |
Geluidsniveau: | 45 dB |
Gewicht verpakking: | 13800 g |
LED-indicatoren: | Ja |
Vormfactor: | Tower |
Afmetingen verpakking (BxDxH): | 235 x 490 x 390 mm |
Aantal USB 2.0-poorten: | 1 |
Aantal Ethernet LAN (RJ-45)-poorten: | 1 |
Geluidsalarm(en): | Ja |
Duurzaamheidscertificaten: | RoHS |
Uitgangsvermogen: | 865 W |
Temperatuur bij opslag: | -5 - 45 °C |
Stroomspanning bescherming: | Overbelasting |
Frequentie: | 50/60 Hz |
Luchtvochtigheid bij opslag: | 0 - 95 procent |
Netwerkfuncties: | Gigabit Ethernet |
Hoogte, in bedrijf: | 0 - 3000 m |
Hoogte bij opslag: | 0 - 15000 m |
Overbelastingsprotectie: | Ja |
Bedrijfstemperatuur (T-T): | 0 - 40 °C |
Relatieve vochtigheid in bedrijf (V-V): | 0 - 95 procent |
Batterijtechnologie: | Sealed Lead Acid (VRLA) |
Type beeldscherm: | LCD |
Surge energy rating: | 355 J |
Aantal AC uitgangen: | 8 AC-uitgang(en) |
Nominale input voltage: | 115 V |
Input-connectietype: | NBR 14136 |
Output power capacity: | 1.5 kVA |
Ingang operation voltage (min): | - V |
Ingang operation voltage (max): | - V |
Uitgang operation voltage (min): | - V |
Uitgang operation voltage (max): | - V |
Typische backup tijd op halve lading: | - min |
Typische backup tijd op volledige lading: | - min |
Netspanning, in bedrijf: | 115 V |
Hoorbare alarmstanden: | Batterijvervanging |
Spanningsbeveiliging: | Ja |
Heb je hulp nodig?
Als je hulp nodig hebt met Apc BR1500G-BR stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding UPS Apc
16 November 2024
12 November 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
Handleiding UPS
- UPS HP
- UPS IKEA
- UPS AEG
- UPS Siemens
- UPS Dell
- UPS Digitus
- UPS Eaton
- UPS Emerson
- UPS Furman
- UPS Gembird
- UPS Gys
- UPS Lenovo
- UPS LevelOne
- UPS Riello
- UPS Schneider
- UPS Voltcraft
- UPS Jung
- UPS Steren
- UPS Conceptronic
- UPS Tripp Lite
- UPS Approx
- UPS Block
- UPS LC-Power
- UPS Energenie
- UPS CyberPower
- UPS Adj
- UPS East
- UPS Equip
- UPS Liebert
- UPS Avocent
- UPS Minute Man
- UPS Minuteman
- UPS Maruson
- UPS V7
- UPS Phoenix Contact
- UPS Puls Dimension
- UPS Vanson
- UPS Salicru
- UPS SurgeX
- UPS Murr Elektronik
- UPS Altronix
- UPS Ditek
- UPS Bxterra
- UPS Middle Atlantic
- UPS FSP
- UPS Atlantis Land
- UPS PowerWalker
- UPS FSP/Fortron
- UPS Online USV
Nieuwste handleidingen voor UPS
18 November 2024
17 November 2024
17 November 2024
17 November 2024
15 November 2024
15 November 2024
14 November 2024
14 November 2024
7 November 2024
7 November 2024