Apc BE750G Handleiding
Lees hieronder de đź“– handleiding in het Nederlandse voor Apc BE750G (2 pagina's) in de categorie UPS. Deze handleiding was nuttig voor 42 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/2
Back-UPS ES 750
User’s Guide
1
2
3
Connect Battery
Power On and Install
Software
Surge Protection
These outlets provide full-time protection from surges even if the Back-UPS ES
is switched OFF. Plug your printer, fax machine, scanner, or other peripherals
that do not need battery power into these outlets.
Place the Back-UPS ES to avoid:
- Direct sunlight
- Excessive heat
- Excessive humidity or contact with fluids
Plug the Back-UPS ES power cord directly into a wall outlet;
not a surge protector or power strip.
Connect Computer Cable
The supplied cable and software provide automatic file saving and shutdown of
the operating system in the case of a sustained power outage.
Connect the cable to the Data Port of the Back-UPS ES. Connect the other end
of the cable to the USB port on your computer. The software will automatically
find the USB Port of your computer.
Battery Back-up + Surge Protection
These outlets are powered whenever the Back-UPS ES is switched ON. During
a power outage or other utility problems (brownouts, over-voltages), these
outlets will be powered for a limited time by the Back-UPS ES. Plug your
computer, monitor, CD-ROM drive and one other data-sensitive device such as
an external disk or tape drive, or Home Phoneline Networking Association
(HPNA) device into these outlets.
Press the ON/OFF switch to power the unit ON.
A single short beep and the green “Power On” indicator
confirms the Back-UPS ES is on and ready to provide
protection.
The Back-UPS ES should charge for at least 16 hours to ensure
sufficient runtime. The unit is being charged whenever it is
connected to utility power, whether the unit is turned ON or
OFF.
If the red Building Wiring Fault indicator (located on the end
near the power cord) is lit, your building wiring presents a shock
hazard that should be corrected by a qualified electrician.
Install the PowerChute® Personal Edition
software
Place the PowerChute Personal Edition CD-ROM into your
computer and follow the installation instructions on the screen.
w
w
w
.apc.com
®
The Back-UPS ES indicates operating status using a combination
of visual and audible indicators. Use the following table to identify
the status of the Back-UPS ES.
Status
Visual Indications
(Power On - Green)
(Replace Battery - Red) Audible Indication
Alarm Terminates
When
Power On - UPS is supplying conditioned utility
power to the load. Power On LED - ON None Not applicable.
On Battery - UPS is supplying battery power to
load connected to Battery outlets. Power On LED - ON (off
during beep) Beeping 4 times
every 30 seconds UPS transfers back to
Power On operation, or
when UPS is turned off.
Low Battery Warning - UPS is supplying battery
power to the load connected to the Battery outlets
and the battery is near exhaustion.
Power On LED - flashing
(every 1/2 second) Rapid beeping
(every 1/2 second) UPS transfers back to
normal operation, or
when UPS is turned off.
Replace Battery - The battery is disconnected.
The battery is in need of charging or is at the end
of its usual life and must be replaced.
Power On and Replace
Battery LEDs- Flashing
(alternating)
Replace Battery LED -
flashing
Constant tone
Constant tone
UPS is turned off with
the power switch.
Overload Shutdown - During On Battery
operation a battery power supplied outlet
overload was detected.
None Constant tone UPS turned off with the
power switch.
Overload Alarm - Online power exceeded
Back-UPS capacity. Power On LED - ON Constant tone Equipment power plugs
are moved from Battery
Backup outlets to
Surge or Client outlets.
Sleep Mode - During On Battery operation the
battery power has been completely exhausted,
and the UPS is waiting for utility power to return
to normal.
None Beeping once every
4 seconds Utility power is
restored, or if utility
power is not restored
within 32 seconds, or
the UPS is turned off.
Building Wiring Fault - Your building wiring
presents a shock hazard that should be corrected
by a licensed electrician.
Building Wiring Fault LED
(red) - ON None UPS is unplugged, or is
plugged into a properly
wired outlet.
Status Indicators
®
See the Troubleshooting section for additional assistance.
For safety, the Back-UPS ES is shipped with one battery wire disconnected. The UPS will not operate until the wire is connected to the touch-safe battery terminal.
NOTE: Small sparks may occur during battery connection. This is normal.
Turn the Back-UPS ES over and press in the release tab.
Slide the plastic battery cover off the unit. Insert the battery back into the compartment. Slide the
plastic battery cover back in place until the tab locks.
1
2
3
Connect Equipment
BatteryCover
Release Tab
Battery
Terminals
Connect the battery wire firmly to the battery terminal.
Idle peripheral devices (printer/scanners, speakers) continue to draw power when not in use. To conserve
power, the Back-UPS uses “master controlled outlets”. The Master outlet senses when the master device
(computer) that is plugged into the Master outlet is no longer drawing current, and automatically shuts off
power to the Controlled outlets. Pressing the MASTER ENABLE button for one second enables and disables
this feature. When enabled, the green MASTER ENABLE LED is lit (on). When it is disabled, the LED is not
lit (off). The Back-UPS ships with MASTER ENABLE activated. Note: Do not connect peripherals to the
Controlled Outlets if you want them to continue to run when your computer is turned off.
Threshold Programming
When the computer is turned off, the Master outlet shuts off power to the Controlled outlets. However, when
the computer goes into “hibernation (sleep) mode” the Master outlet may not properly recognize the reduced
power level. To ensure the Master outlet shuts off power to the Controlled outlets properly, the threshold set-
ting may need to be adjusted from the “default value”. If the peripherals plugged into the Controlled outlets
do not turn off when the computer goes into hibernation mode, first ensure the MASTER ENABLE LED is lit,
and if so, then perform the procedure provided below to switch the threshold setting to High. Conversely, if
the computer has an extremely low power level, it may require that the threshold setting be set to Low if the
Controlled outlets automatically shut off, even when the computer is running. The Back-UPS automatically
exits this mode in five seconds if no buttons are pushed, or no operations are run. The three threshold set-
tings that can be selected are summarized in the table below.
Perform the following steps to change the threshold settings:
1. Plug the Back-UPS into the utility power source; do not turn power on. The unit will be in standby mode
(no LEDs are lit).
2. Press and hold down the MASTER ENABLE button for 10 seconds, until all indicators flash to show it has
entered threshold programming mode.
3. When the MASTER ENABLE button is released, the LEDs that are illuminated indicate the current thresh-
old setting (Low, Medium or High).
4. Press the MASTER ENABLE button to select a different threshold setting.
Indicators Flashing Threshold Setting
Input Wattage Range
(Hibernation Mode)
1. Master Enable LED Low 10 Watts
2. Master Enable LED, On Line LED Medium (default) 25 Watts
3. Master Enable, On Line, Replace Battery LEDs High 60 Watts
Master/Controlled Outlets
Battery Wires
Connect Modem / Phone / DSL / Fax / 10/100Base-T / HPNA /
Cable Modem / CATV or DSS to Surge Protection
The Back-UPS protects a single line (2-wire) phone (including Digital Subscriber
Line - DSL), Home Phoneline Networking Association (HPNA) type equipment,
modem, 10/100Base-T Ethernet, or fax machines from surges when connected
through the UPS as shown in the drawing. The UPS also protects a cable
modem, CATV converter, or DSS receiver from surges when it is connected
through the UPS coaxial connectors as shown in the drawing.
Master
Controlled by Master
Battery Backup+
Surge Protection
Surge Protection
From Wall Jack
Dataline Output to
DSL Modem, Phone
Building Wiring
Fault Indicator
Cable Input
from Internet
Service
Cable Output
to Cable,
Modem, CATV
Converter,
or DSS Input
Circuit
Breaker
Troubleshooting
Use the table below to solve minor Back-UPS ES installation or operation problems. Consult APC Online Technical Support or call APC
Technical Support for assistance with problems that cannot be resolved using the table below:
Back-UPS ES will not turn on.
No power available at the Surge Protection
outlets.
Back-UPS turns on, but LED flashes and unit
emits a constant tone.
Connected equipment loses power.
The Power On indicator is lit and the Back-
UPS ES is beeping four times every 30
seconds.
The Power On indicator flashes and beeps
twice per second at the same time.
Building Wiring Fault indicator is lit.
Inadequate runtime.
No phone/fax/DSL/cable or network signal
from the Back-UPS.
Connect the battery (see Connect Battery) and ensure power is available at the wall
outlet. If battery is connected and power is unavailable, the unit can be “cold started”
(operated on battery power) by holding the power button down until two beeps are
heard.
Reduce the amount of equipment plugged into Surge Protection outlets.
Ensure the fuse or circuit breaker for the outlet is not tripped, and that the wall switch
controlling the outlet (if any) is in the ON position.
Connect the battery (see Connect Battery diagram).
Ensure the equipment you want to stay powered during a power failure is plugged
into the “Battery Backup plus Surge Protection” outlets and NOT the “Surge
Protection” outlets.
Make sure the equipment plugged into the outlets of the unit are not overloading its
capacity. Try removing some of the equipment and see if the problem continues.
The Back-UPS ES is operating normally.
The Back-UPS ES can only operate on battery power for a limited amount of time.
The unit will eventually turn off when the available battery power has been used.
Allow the unit to recharge for 16 hours before expecting maximum runtime.
The output waveform is designed for computers and computer-related equipment. It
is not designed for use with motor-type equipment.
Contact APC Technical Support for further troubleshooting.
The Back-UPS ES is operating normally and using battery power. Once On Battery,
you should save your current work, power down your equipment, and turn the unit
OFF. Once normal power is restored, you may turn the unit back ON and power your
equipment.
The Back-UPS ES is about to shut off due to a low battery charge condition! When
the unit beeps twice every second, the battery has about 2 minutes of power
remaining. Immediately power down your computer and turn the unit OFF. When
normal power returns, the unit will recharge the battery.
Call a qualified electrician for service.
Allow the unit to charge by leaving it plugged into the wall for at least 16 hours.
As a battery ages, the amount of runtime available will decrease. You can replace the
battery by ordering one at www.apc.com. Batteries also age prematurely if the Back-
UPS ES is placed near excessive heat.
Make sure the data line from the wall outlet is connected to the jack labeled “Wall
Outlet (Phone/Fax/DSL), or “Cable In” (Cable/DSS/CATV).
Problem Probable Cause Solution
Specifications
Warranty
Service
APC Contact Information
Input Voltage 120 Vrms Nominal
Frequency 50 - 60 Hz (auto-sensing)
Brownout Transfer 88 Vrms, typical
Over-voltage Transfer 142 Vrms, typical
Output UPS Capacity (5 outlets) 750 VA / 450 W
Total Amperage (10 outlets) 12 Amps (including UPS output)
Voltage
On Battery 115 Vrms + 8%
(step-approximated sine wave)
Frequency - On Battery 50-60 Hz + 1 Hz
Transfer Time 6 ms typical, 10 ms maximum
Protection and Filter AC Surge Protection Full time, 354 joules
Phone/Fax/DSL Surge
Protection Single line (2-wire)
Cable/CATV/DSS Surge
Protection One Coax Input/Output
Network Surge Protection 10/100Base-T Ethernet
EMI/RFI Filter Full time
AC Input Resettable circuit breaker
Battery Model RBC17
Type Sealed, maintenance-free lead acid
Average Life 3 - 5 years depending on the number of discharge
cycles and environmental temperature
Physical Net Weight 10.36 lb. (4.70 kg.)
Size 3.5" (H) x 13.5" (W) x 7.1" (D)
(88.3 x 342.7 x 180.0 mm)
Operating Temperature +32oF to 104oF (0oC to 40oC)
Storage Temperature +5oF to 113oF (-15oC to 45oC)
Operating Relative Humidity 0 to 95% non-condensing
Operating Elevation 0 to 10,000 ft (0 to 3,000m)
Safety/Regulatory Safety Approvals TUV C-US certified per UL Std. 1778 and CSA 22.2
No. 107.1, NOM-001
EMC Compliance Notice: This device complies with part 68 and
part 15 of the FCC rules. Operation is subject to
the following two conditions: (1) This device may
not cause harmful interference, and (2) This
device must accept any interference received,
including interference that may cause undesired
operation.
On the bottom of this equipment is a label that
contains, among other information, the FCC
registration number and ringer equivalence
number (REN) for this equipment.
If requested, this information must be provided
to the telephone company.
Model BE750G
The standard warranty is 3 years from the date of purchase. APC’s standard procedure
is to replace the original unit with a factory reconditioned unit. Customers who must
have the original unit back due to assigned asset tags and set depreciation schedules
must declare such a need at first contact with APC Technical Support. APC will ship the
replacement unit once the defective unit is received by the repair department or cross-
ship upon the provision of a valid credit card number. The customer pays for shipping
to APC, and APC pays ground freight transportation costs back to the customer.
Please DO NOT RETURN Back-UPS ES to the place of purchase under any
circumstances.
1. Consult the Troubleshooting section to eliminate common problems.
2. Verify the battery is connected (see Connect Battery) and that the Circuit Breaker is
not tripped (see Troubleshooting section).
If you still have problems or questions, please contact APC via the internet or at one of
the phone numbers listed below.
3. Before contacting APC, please be sure to record the date purchased, UPS model,
and serial number (on bottom of unit).
4. Be prepared to troubleshoot the problem over the telephone with a Technical
Support Representative. If this is not successful, the representative will issue a Return
Material Authorization Number (RMA#) and a shipping address.
5. Pack the unit in its original packaging. If the original packaging is not available, ask
APC Technical Support about obtaining a new set. Pack the unit properly to avoid
damage in transit. Never use foam beads for packaging. Damage sustained in transit is
not covered under warranty (insuring the package for full value is recommended).
6. Write the RMA# on the outside of the package.
7. Return the unit by insured carrier to you by APC Technical the address given to
Support.
Online Technical Support: http://support.apc.com
http://www.apc.com/support
esupport@apcc.com
Web Site: www.apc.com
USA/Canada: 1.800.800.4272
Mexico: +52.292.0253 / 52.292.0255
Brazil: +0800.12.72.1
Worldwide: +1.401.789.5735
Order Replacement Battery
Replace with an APC qualified battery. Replacement batteries can be ordered from
www.apc.com (valid credit card required). Have your Back-UPS ES model number
available when ordering. Your model number can be found on the bottom of the unit.
The battery is disconnected, and either power is
unavailable at the wall outlet, or utility power is having a
“brownout” or an “over voltage” condition.
Surge Protection outlets have been overloaded.
Utility power not available at the wall outlet.
Battery is disconnected.
Equipment is connected to the “Surge Protection” outlets.
The Back-UPS ES is overloaded.
PowerChute Personal Edition software has performed a
shutdown due to a power failure.
The Back-UPS ES has exhausted its available battery
power.
Connected equipment does not accept the step-
approximated sine waveform the Back-UPS ES.
The Back-UPS ES may require service.
The Back-UPS ES is using battery.
Battery capacity is low (about 2 minutes of use remaining).
Your building wiring presents a shock hazard. Using the
Back-UPS with this condition will void the warranty.
The battery is not fully charged.
Battery is near the end of useful life.
Data line from the ISP or wall outlet is connected to the
wrong jack on the Back-UPS.
Internet connection lost during power outage. Modem lost AC power. Plug the modem’s AC power cord into one of the “Battery Back-up plus Surge
Protection” outlets.
APC, Back-UPS and PowerChute are registered trademarks of American Power Conversion Corp.
Copyright © 2007 American Power Conversion Corp.
All other trademarks are property of their respective owners.
990-3153A 9/07
Product specificaties
Merk: | Apc |
Categorie: | UPS |
Model: | BE750G |
Kleur van het product: | Zwart |
Gewicht: | 4700 g |
Snoerlengte: | 1.8 m |
Gewicht verpakking: | 5700 g |
LED-indicatoren: | Ja |
Afmetingen verpakking (BxDxH): | 258 x 452 x 151 mm |
Certificering: | FCC Part 15 Class B/FCC Part 68/NOM/UL 1778 |
Uitgangsvermogen: | 450 W |
Accu/Batterij oplaadtijd: | 16 uur |
Temperatuur bij opslag: | -15 - 45 °C |
Frequentie: | 50/60 Hz |
Luchtvochtigheid bij opslag: | 5 - 95 procent |
Gewicht (imperiaal): | 10.34 lbs |
Bedrijfstemperatuur, bereik: | 0 - 40 °F |
Hoogte, in bedrijf: | 0 - 3000 m |
Relatieve luchtvochtigheid bij opslag (geen condensering): | 0 - 95 procent |
Afmetingen (B x D x H): | 180 x 343 x 88 mm |
Producten per pallet: | 72 stuk(s) |
Bedrijfstemperatuur (T-T): | 0 - 40 °C |
Relatieve vochtigheid in bedrijf (V-V): | 5 - 95 procent |
Surge energy rating: | 365 J |
Nominale input voltage: | 120 V |
Input-connectietype: | NEMA 5-15P |
Output power capacity: | 0.75 kVA |
Typische backup tijd op halve lading: | 11.3 min |
Typische backup tijd op volledige lading: | 2.3 min |
Hot-swap batterij: | Ja |
Netspanning, in bedrijf: | 120 V |
Output-aansluitingen: | 10 x NEMA 5-15R |
Heb je hulp nodig?
Als je hulp nodig hebt met Apc BE750G stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding UPS Apc
2 December 2024
2 December 2024
2 December 2024
2 December 2024
16 November 2024
12 November 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
12 Oktober 2024
Handleiding UPS
- UPS HP
- UPS IKEA
- UPS AEG
- UPS Siemens
- UPS Dell
- UPS Digitus
- UPS Eaton
- UPS Emerson
- UPS Furman
- UPS Gembird
- UPS Gys
- UPS Lenovo
- UPS LevelOne
- UPS Riello
- UPS Schneider
- UPS Voltcraft
- UPS Jung
- UPS Steren
- UPS Conceptronic
- UPS Tripp Lite
- UPS Approx
- UPS Block
- UPS LC-Power
- UPS Energenie
- UPS CyberPower
- UPS Adj
- UPS East
- UPS Equip
- UPS Liebert
- UPS Avocent
- UPS Minute Man
- UPS Minuteman
- UPS Maruson
- UPS V7
- UPS Phoenix Contact
- UPS Puls Dimension
- UPS Vanson
- UPS Salicru
- UPS SurgeX
- UPS Murr Elektronik
- UPS Altronix
- UPS Ditek
- UPS Bxterra
- UPS Middle Atlantic
- UPS FSP
- UPS Atlantis Land
- UPS PowerWalker
- UPS FSP/Fortron
- UPS Online USV
Nieuwste handleidingen voor UPS
14 December 2024
14 December 2024
10 December 2024
10 December 2024
8 December 2024
8 December 2024
18 November 2024
17 November 2024
17 November 2024
17 November 2024