Apc BE450G-LM Handleiding

Apc UPS BE450G-LM

Lees hieronder de 📖 handleiding in het Nederlandse voor Apc BE450G-LM (6 pagina's) in de categorie UPS. Deze handleiding was nuttig voor 26 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/6
Back-UPS® ES 450/550G
User Guide
1
2
3
Connect Battery
Equipment
Turn the Unit On
Surge Protection
These outlets provide full-time protection from surges even if the
Back-UPS ES is switched OFF. Plug your printer, fax machine,
scanner, or other peripherals that do not need battery power into these
outlets.
Battery Back-up +Surge Protection
These outlets are powered whenever the Back-UPS ES is
switched ON. During a power outage or other utility problems
(brownouts, over-voltages), these outlets will be powered for a
limited time by the Back-UPS ES. Plug your computer,
monitor, and other peripheral devices into the outlets.
Press the ON/OFF switch turn the unit ON.
A single short beep and the green “Power On” indicator confirms
the Back-UPS ES is on and ready to provide protection.
The Back-UPS ES should charge for at least 16 hours to ensure
sufficient runtime. The unit is being charged whenever it is
connected to utility power, whether the unit is turned ON or OFF.
If the red Building Wiring Fault indicator (located on the end near
the power cord) is lit, your building wiring presents a shock hazard
that should be corrected by a qualified electrician.
Install the PowerChute Personal Edition software.
Place the PowerChute CD into the computer and following the
installation instructions on the screen.
w
w
w
.apc.com
®
The Back-UPS ES indicates operating status using a combination of visual and audible
indicators. Use the following table to identify the status of the Back-UPS ES.
Status
Visual Indications
(Power On - Green)
(Replace Battery -
Red)
Audible Indication Alarm Terminates When
Power On - UPS is supplying
conditioned utility power to the load.
Power On pushbutton
- ON (lit)
None Not applicable.
On Battery - UPS is supplying
battery power to the load connected
to the Battery outlets.
Power On pushbutton
- ON (off during beep)
Beeping 4 times every
30 seconds
UPS transfers back to
Power On operation, or
when UPS is turned off.
Low Battery Warning - UPS is
supplying battery power to the load
connected to the battery outlets, and
the battery is near exhaustion.
Power On indicator is
flashing
Rapid beeping (every
1/2 second)
UPS transfers back to
normal operation, or when
UPS is turned off.
Replace Battery - The battery is
disconnected.
The battery is in need of charging, or
is at the end of its usual life and must
be replaced.
Replace Battery
indicator is Flashing
Power On and
Replace Battery
indicators - flashing
(alternating)
Constant tone
Constant tone
UPS is turned off with the
power switch.
Overload Shutdown - During On
Battery operation a battery power
supplied outlet overload was
detected.
None Constant tone UPS is turned off with the
power switch.
Sleep Mode - During On Battery
operation the battery power has
been completely exhausted and the
UPS is waiting for utility power to
return to normal.
None Beeping once every 4
seconds
Utility power is restored,
or if utility power is not
restored within 32
seconds, or the UPS is
turned off.
Building Wiring Fault - Your
building wiring presents a shock
hazard that should be corrected by a
licensed electrician.
Building Wiring Fault
LED (red) - ON
None UPS is unplugged, or
UPS is plugged into a
properly wired outlet.
Status Indicators
For safety, the Back-UPS ES is shipped with one battery wire disconnected. The UPS will not operate until the wire is connected to the touch-safe battery terminal.
NOTE: Small sparks may occur during battery connection. This is normal.
Turn the Back-UPS ES over and press in the
release tab. Slide the plastic battery cover off of the
Back-UPS.
Insert the battery back into the compartment.
Slide the plastic battery cover until the release tab
locks into place.
Connect the battery wire firmly to the
battery terminal.
Connect
Connect Modem / Phone / DSL / Fax
The Back-UPS protects a single line (2-wire) phone (including Digital Subscriber Line - DSL),
Home Phoneline Networking Association (HPNA) type equipment, modem, or fax machines
from surges when connected through the UPS as shown in the drawing below.
Place the Back-UPS ES to avoid:
- Direct sunlight
- Excessive heat
- Excessive humidity or contact with fluids
Plug the Back-UPS ES power cord directly into a wall outlet; not into a surge protector
or power strip.
Connect Computer Cable
The supplied cable and software provide automatic file saving and shutdown of the operating
system in the case of a sustained power outage.
Connect the cable to the Data Port of the Back-UPS ES. Connect the other end of the cable to
the USB port on your computer. The software will automatically find the computer’s USB Port.
and Install the Software
Transfer Voltage and
Sensitivity Adjustment
(Optional)
To adjust the transfer voltage:
1. Plug the Back-UPS into the utility power source. The Back-UPS
will be in Standby mode” (no indicators are lit).
2. Press the ON/OFF push button fully in for 10 seconds. The
Online LED will begin glowing in a cyclical order: GREEN-
AMBER-RED, indicating it is going into “Program mode”.
3. The Back-UPS will then indicate the current
sensitivity, as shown in the Transfer Voltage and Sensitivity
Adjustment table below.
4. To select the LOW sensitivity setting, press the ON/OFF push
button until the LED begins
flashing GREEN.
5. To select the MEDIUM sensitivity setting, press the ON/OFF
push button until the LED begins flashing RED.
6. To select the HIGH sensitivity setting, press the ON/OFF push
button until the LED begins
flashing AMBER.
7. To exit Programming mode, once sensitivity is set, wait
approximately 5 seconds, and all of the LED indicators will be
off (unlit).
4
Indicators
Flashing Sensitivity Setting Input Voltage Range
(For Utility Operation) When to Use
Green
Flashing
LOW 88-142 Input voltage is extremely low or
high.
Not recommended for computer
loads.
Red Flashing MEDIUM
(factory default)
92-139 Back-UPS frequently goes on
battery.
Amber
Flashing
HIGH 96-136 Connected equipment is
sensitive to voltage
fluctuations.
Troubleshooting
Problem Probable Cause Solution
Back-UPS ES will not turn
on.
The battery is disconnected, and either power is
unavailable at the wall outlet, or utility power is
having a “brownout” or an “over voltage”
condition.
Connect the battery (see Connect Battery) and ensure power is available at the wall outlet. If
battery is connected and power is unavailable, the unit can be “cold started” (operated on
battery power) by holding the power button down until two beeps are heard.
No power available at the
Surge Protection outlets.
Surge Protection outlets were overloaded. Reduce the amount of equipment plugged into the Surge Protection outlets.
Utility power not available at the wall outlet. Ensure the fuse or circuit breaker for the outlet is not tripped, and that the wall switch
controlling the outlet (if any) is in the ON position.
Back-UPS is on, but
Replace Battery indicator
flashes, and unit emits a
constant tone.
Battery is disconnected. Connect the battery (see Connect Battery diagram).
Connected equipment
loses power.
Equipment is connected to the “Surge Protection”
outlets.
Ensure the equipment you want to stay powered during a power failure is plugged into the
“Battery Backup plus Surge Protection” outlets and NOT the “Surge Protection Onlyoutlets.
The Back-UPS ES is overloaded. Make sure the equipment plugged into the outlets of the unit are not overloading its capacity. Try
removing some of the equipment and see if the problem continues.
PowerChute Personal Edition software has
performed a shutdown due to a power failure.
The Back-UPS ES is operating normally.
The Back-UPS ES has exhausted its available
battery power.
The Back-UPS ES can only operate on battery power for a limited amount of time. The unit
will eventually turn off when the available battery power has been used. Allow the unit to
recharge for 16 hours before expecting maximum runtime.
Connected equipment does not accept the step-
approximated sine waveform from the Back-UPS
ES.
The output waveform is designed for computers and computer-related equipment. It is not
designed for use with motor-type equipment.
The Back-UPS ES may require service. Contact APC Technical Support for further troubleshooting.
The Power On indicator is
lit and the Back-UPS ES
beeps four times every 30
seconds.
The Back-UPS ES is On Battery. The Back-UPS ES is operating normally, and using battery power. Once On Battery, you may
want to save your current work, power down your equipment, and turn the unit OFF. Once
normal power is restored, you may turn the unit back ON, and power your equipment.
The Power On indicator
flashes and the Back-UPS
beeps twice per second at
the same time.
Battery capacity is low (about 2 minutes of use
remaining).
The Back-UPS ES is about to shut off due to a low battery charge condition! When the unit
beeps twice every second, the battery has about 2 minutes of power remaining. Immediately
power down your computer ,and turn the unit OFF. When normal power returns, the unit will
recharge the battery.
Building Wiring Fault
indicator is lit.
Your building wiring presents a shock hazard.
Using the Back-UPS with this condition will void
the warranty.
Call a qualified electrician for service.
Inadequate runtime. The battery is not fully charged. Allow the unit to charge by leaving it plugged into the wall at least 16 hours.
Battery is near the end of useful life. As a battery ages, the amount of runtime available will decrease. You can replace the battery
by ordering one at www.apc.com. Batteries also age prematurely if the Back-UPS ES is
placed near excessive heat.
No phone/fax/DSL signal
from the Back-UPS.
Data line from the ISP or wall outlet is connected
to the wrong jack on the Back-UPS. Make sure the data line from the wall outlet is connected to the jack labeled “Wall Outlet”.
Internet connection lost
during power outage.
Modem lost AC power. Plug the modem’s AC power cord into one of the “Battery Back-up Plus Surge Protection
outlets”.
APC Contact Information
Online Technical Support: http://support.apc.com
http://www.apc.com/support
esupport@apcc.com
Web Site: www.apc.com
USA/Canada: 1.800.800.4272
Mexico: +52.292.0253 / 52.292.0255
Brazil: +0800.12.72.1
Worldwide: +1.401.789.5735
Service
Please DO NOT RETURN Back-UPS ES to the place of purchase under any
circumstances.
1. Consult the Troubleshooting section to eliminate common problems.
2. Verify the battery is connected (see Connect Battery) and that the Circuit Breaker is
not tripped (see Troubleshooting section).
If you still have problems or questions, please contact APC via the internet or at one of
the phone numbers listed below.
3. Before contacting APC, please be sure to record the date purchased, UPS model,
and serial number (on bottom of unit).
4. Be prepared to troubleshoot the problem over the telephone with a Technical
Support Representative. If this is not successful, the representative will issue a Return
Material Authorization Number (RMA#) and a shipping address.
5. Pack the unit in its original packaging. If the original packaging is not available, ask
APC Technical Support about obtaining a new set. Pack the unit properly to avoid
damage in transit. Never use foam beads for packaging. Damage sustained in transit is
not covered under warranty (insuring the package for full value is recommended).
6. Write the RMA# on the outside of the package.
7. Return the unit by insured carrier to the address given to you by APC Technical
Support.
Warranty
The standard warranty is 3 years from the date of purchase. APC’s standard
procedure is to replace the original unit with a factory reconditioned unit. Customers
who must have the original unit back due to assigned asset tags and set depreciation
schedules must declare such a need at first contact with APC Technical Support. APC
will ship the replacement unit once the defective unit is received by the repair
department or cross-ship upon the provision of a valid credit card number. The
customer pays for shipping to APC, and APC pays ground freight transportation costs
back to the customer.
Order Replacement Battery
Replace with an APC qualified battery. Replacement batteries can be ordered from
www.apc.com (valid credit card required). The replacement battery part number for
this Back-UPS 450 is RBC 114, and for Back-UPS 550 is RBC 110.
Specifications
Model BE450/550G
Input Voltage 120 Vrms nominal
Frequency 60 Hz + 3
Brownout Transfer 92 Vrms, typical
Over-voltage Transfer 139 Vrms, typical
Output UPS Capacity (4 outlets) 450 VA/550 VA ; 257 W/330 W
Total Amperage (8 outlets) 12 Amps (including UPS output)
Voltage - On Battery 115 Vrms + 8% (step-approximated sine wave)
Frequency - On Battery 60 Hz + 1 Hz
Transfer Time 6 ms typical, 10 ms maximum
Protection and
Filter
AC Surge Protection Full time, 340 joules
Phone/fax/DSL Surge
Protection
Single line (2-wire)
EMI/RFI Filter Full time
AC Input Resettable circuit breaker
Battery Type Sealed, maintenance-free lead acid
Average Life 3 - 5 years depending on the number of discharge cycles
and environmental temperature
Physical Net Weight Back-UPS 450: 10 lb ( 4.5 kg)
Back-UPS 550: 12.4 lb (5.6 kg)
Size 11.2 in (H) x 7.1 in (W) x 3.4 in (D)
(28.2 cm x 18 cm x 8.7cm)
Operating Temperature +32oF to 104oF (0oC to 40oC)
Storage Temperature +5oF to 113oF (-15
oC to 45o
C)
Operating Relative Humidity 0 to 95% non-condensing
Operating Elevation 0 to 10,000 ft (0 to 3,000m)
Safety and
Regulatory
Safety Approvals TUV C-US certified; UL 1778 standard per CSA
standard C22.2 No. 107.3, FCC part 68 &
FCC part 15 Class B, NOM certified
EMC Compliance Notice: This device complies with part 68 and part 15 of
the FCC rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful
interference, and (2) This device must accept any
interference received, including interference that may
cause undesired operation.
“On the bottom of this equipment is a label that contains,
among other information, the FCC registration number
and ringer equivalence number (REN) for this equipment.
If requested, this information must be provided to the
telephone company.
990-3313A Copyright © 2008 American Power Conversion Corp.
All other trademarks are property of their respective owners.
APC, Back-UPS and PowerChute are registered trademarks of American Power Conversion Corp.
Back-UPS® ES
450/550G
Guía de usuario
Conexión de la batería
Encendido de la unidad e
Protección contra sobrevoltajes
Estos tomacorrientes proporcionan una protección completa contra
sobrevoltajes incluso si el Back-UPS ES se encuentra apagado.
Enchufe en estos tomacorrientes la impresora, máquina de fax,
escáner u otros periféricos que no necesiten energía de la batería.
Energía de la batería +Protección contra
sobretensiones
Estos tomacorrientes estarán alimentados siempre que el Back-
UPS ES se encuentre encendido. Durante un corte de energía u
otros problemas relacionados con la alimentación eléctrica
(bajas de tensión, sobrevoltajes, etc.), el Back-UPS ES
proporcionará energía a los tomacorrientes durante un tiempo
limitado. Enchufe en estos tomacorrientes el ordenador, monitor
y otros periféricos.
Presione el botón de ENCENDIDO/APAGADO para encender
la unidad.
Un solo pitido corto y el indicador verde “Power On” confirman
que el Back-UPS ES se encuentra encendido y listo para
proporcionar protección.
Se deberá cargar el Back-UPS ES durante al menos 16 horas
para asegurar un tiempo de funcionamiento adecuado. La unidad
realizará la carga de la batería siempre que se encuentre
enchufada a la energía eléctrica, independientemente de si se
encuentra encendida o apagada.
Si se enciende el indicador “Building Wiring Fault” (ubicado en el
extremo que está cerca del cable de alimentación), la edificación
presenta un peligro de descarga eléctrica que deberá ser resuelto
por un electricista matriculado.
Instale el software PowerChute Personal Edition.
Coloque el CD de PowerChute CD en el ordenador y siga las
instrucciones de instalación que aparecen en la pantalla.
w
w
w
.apc.com
®
El Back-UPS ES indica el estado de funcionamiento utilizando una combinación de
indicadores visuales y sonoros. Utilice la siguiente tabla para identificar el estado del Back-
UPS ES.
Estado
Indicaciones visuales
(Power On (Encendido) - Verde)
(Replace Battery (Reemplazar
batería) - Rojo)
Indicación
sonora
La alarma se detiene
cuando
En línea - El UPS es
suministrando energía eléctrica
adaptada a la carga.
Indicador “Power On” –
ENCENDIDO (iluminado) Ninguno. No corresponde.
Funcionando con la batería -
El UPS está suministrando
energía de la batería a la
cargas que se encuentra
enchufada en los
tomacorrientes de la batería.
Indicador “Power On” -
ENCENDIDO (apagado durante
los pitidos)
4 pitidos cada
30 segundos. El UPS regresa al
funcionamiento con energía
eléctrica o cuando el UPS se
apaga.
Advertencia de batea baja -
El UPS está suministrando
energía de la batería a la carga
enchufada a los tomacorrientes
de la batería y la batería está a
punto de agotarse.
Parpadeo del indicador “Power
On”. Pitidos rápidos
(cada medio
segundo).
El UPS regresa al
funcionamiento normal o
cuando el UPS se apaga.
Reemplazar batería - La
batería está desconectada.
Se debe cargar la batería o ésta
llegó al final de su vida útil y
deberá ser reemplazada.
Parpadeo de indicador “Replace
Battery”.
Indicadores “Power On” y
“Replace Battery” - parpadeando
(de forma alternada)
Tono constante.
Tono constante.
Se apagó el UPS con el
interruptor de encendido/
apagado.
Apagado por sobrecarga -
Durante el funcionamiento con
la batería, se detectó una
sobrecarga en un tomacorriente
al que se le está proporcionado
energía de la batería.
Ninguno. Tono constante. Se apagó el UPS con el
interruptor de encendido/
apagado.
Modo de espera - Durante el
funcionamiento con la batería,
la carga de la batería se agotó
por completo y el UPS está
esperando que le energía
eléctrica regrese a la
normalidad.
Ninguno. Pitidos cada 4
segundos. Regrese la energía eléctrica,
cuando la enera eléctrica
no haya regresado al cabo
de 32 segundos o cuando se
apague el UPS.
Falla en el cableado de la
edificación - El cableado de la
edificación presenta un peligro
de descarga eléctrica que
deberá ser resuelto por un
electricista matriculado.
Indicador LED “Building Wiring
Fault” (Falla en el cableado de la
edificación) (rojo) - ENCENDIDO.
Ninguno. Se desenchufe el UPS o
cuando se enchufe el UPS a
un tomacorriente de pared
con un cableado correcto.
Indicadores de estado
Por razones de seguridad, se envía el Back-UPS ES con un cable de la batería desconectado. La UPS no funcionará hasta que se conecte el cable al terminal de
la batería seguro al tacto. NOTA: Es posible que se produzcan algunas chispas durante la conexión de la batería. Esto es normal.
Voltee el Back-UPS ES y presione el pestillo de
liberación. Deslice hacia fuera la tapa de
plástico de compartimiento de la batería.
Coloque nuevamente la batería en el
compartimiento. Deslice la tapa de plástico del
compartimiento de la batería hasta que el pestillo
de liberación quede asegurado en su lugar.
Conecte el cable de la batería de
forma firme al terminal de la batería.
Conexión de dispositivos
Conexión de módem / teléfono / DSL / fax
El Back-UPS ES brinda protección contra sobrevoltajes a teléfonos de una sola línea (2
alambres) (incluida la Línea de Suscripción Digital – DSL, por sus siglas en inglés), equipos
HPNA (Alianza de Redes de Líneas Telefónicas Domésticas), módems o máquinas de fax
cuando se encuentran enchufados a través del UPS como se muestra en la ilustración que
aparece abajo.
No exponga el Back-UPS ES a las siguientes condiciones:
- Luz solar directa
- Calor excesivo
- Humedad excesiva o contacto con fluidos
Enchufe el Back-UPS ES directamente en un tomacorriente de pared y no en un
protector contra sobretensiones ni múltiple.
Conexión del cable del ordenador
El cable suministrado y el software proporcionan un almacenamiento automático de archivos
y apagado del sistema operativo en caso de un corte de energía ininterrumpido.
Conecte el cable al puerto Data Port (Puerto de datos) del Back-UPS ES. Conecte el otro
extremo del cable al puerto USB del ordenador. El software buscará automáticamente el
puerto USB del ordenador.
Ajuste de voltaje y
sensibilidad de la
transferencia (opcional)
Para ajustar el voltaje de transferencia:
1. Enchufe el Back-UPS ES a la fuente de energía eléctrica. El
Back-UPS ES ingresará en el “modo de espera” (no se
encenderá ningún indicador).
2. Mantenga presionado el botón de ENCENDIDO/APAGADO
durante 10 segundos. El indicador LED comenzará a parpadear en
un orden cíclico: VERDE-ÁMBAR-ROJO, lo que indica que el
Back-UPS ES ingresará en el “modo de programación”.
3. El Back-UPS ES indicará la sensibilidad actual, como muestra la
tabla Ajuste de voltaje y sensibilidad de la transferencia que
aparece más adelante.
4. Para seleccionar la configuración de sensibilidad BAJA, presione
el botón de ENCENDIDO/APAGADO hasta que el indicador LED
comience a parpadear de color VERDE.
5. Para seleccionar la configuración de sensibilidad MEDIA,
presione el botón de ENCENDIDO/APAGADO hasta que el
indicador LED comience a parpadear de color ROJO.
6. Para seleccionar la configuración de sensibilidad ALTA, presione
el botón de ENCENDIDO/APAGADO hasta que el indicador LED
comience a parpadear de color ÁMBAR.
7. Para salir de modo de programación, una vez que se haya
establecido la sensibilidad, espere aproximadamente 5 segundos
y todos los indicadores LED se apagarán.
Indicadores
LED
parpadeando de
color
Configuración de
sensibilidad
Rango del voltaje de
entrada (para el
funcionamiento con
energía eléctrica)
Se recomienda utilizar esta
configuración cuando
Verde
parpadeando
BAJA 88-142 El voltaje de entrada es
extremadamente bajo o alto. No
recomendado para cargas
pertenecientes a computadoras.
Rojo
parpadeando
MEDIA
(configuración por
defecto de fábrica)
92-139 El Back-UPS ES funciona de forma
frecuente con la batería.
Ámbar
parpadeando
ALTA 96-136 Los equipos conectados son sensibles
a las fluctuaciones en el voltaje.
instalación del software
1 2 3


Product specificaties

Merk: Apc
Categorie: UPS
Model: BE450G-LM
Kleur van het product: Zwart
Gewicht: 5910 g
Breedte: 305 mm
Diepte: 178 mm
Hoogte: 84 mm
Snoerlengte: 1.52 m
Geluidsniveau: 45 dB
Gewicht verpakking: 6500 g
LED-indicatoren: Ja
Vormfactor: Compact
Afmetingen verpakking (BxDxH): 438 x 140 x 241 mm
Aantal USB 2.0-poorten: 1
Certificering: cUL, FCC p15 B, FCC p68, NOM, UL 1778, UL 497A, UL 497B
Geluidsalarm(en): Ja
Duurzaamheidscertificaten: RoHS
Uitgangsvermogen: 257 W
Temperatuur bij opslag: -15 - 45 °C
Frequentie: 50/60 Hz
Luchtvochtigheid bij opslag: 5 - 95 procent
Hoogte, in bedrijf: 0 - 3000 m
Hoogte bij opslag: 0 - 15000 m
Modem (RJ-11) poort: 1
Bedrijfstemperatuur (T-T): 0 - 40 °C
Relatieve vochtigheid in bedrijf (V-V): 5 - 95 procent
Batterijtechnologie: Sealed Lead Acid (VRLA)
Type beeldscherm: LED
Aantal AC uitgangen: 8 AC-uitgang(en)
Nominale input voltage: 120 V
Stopcontacttypes: NEMA 5–15R
Output power capacity: 0.45 kVA
Ingang operation voltage (min): - V
Ingang operation voltage (max): - V
Uitgang operation voltage (min): - V
Uitgang operation voltage (max): - V
Netspanning, in bedrijf: 120 V

Heb je hulp nodig?

Als je hulp nodig hebt met Apc BE450G-LM stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding UPS Apc

Handleiding UPS

Nieuwste handleidingen voor UPS