Apc Back-UPS Pro BR1500G Handleiding

Apc UPS Back-UPS Pro BR1500G

Lees hieronder de 📖 handleiding in het Nederlandse voor Apc Back-UPS Pro BR1500G (8 pagina's) in de categorie UPS. Deze handleiding was nuttig voor 47 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/8
Installation and Operation
Back-UPS Pro 1300G/1500G
Connect the Battery
Install PowerChute Personal Edition Software
APC PowerChute Personal Edition software provides automatic file saving and shutdown of your
computer in the event of a power failure. Use the cable supplied with the Back-UPS to connect the
data port on the Back-UPS to the USB port on your comput er.
To download, go to www.apc.com/pcpe. Select the appropriate operating system and follow
directions to download the software.
APC PowerChute is compatible with a window operating system only. Visit.
http://www.apc.com/wp/?um=300. for OS compatibility list.
Inventory Safety and General Information
Inspect the package contents upon receipt. Notify the
carrier and dealer if there is any damage.
Read the Safety Guide supplied with this unit before
installing the UPS.
This UPS is intended for indoor use only.
Do not operate this UPS in direct sunlight, in contact with fluids, or where there is
excessive dust or humidity.
Be sure the air vents on the UPS are not blocked. Allow adequate space for proper
ventilation.
The battery typically lasts for three to five years. Environmental factors impact
battery life. Elevated ambient temperatures, poor quality AC power, and frequent
short duration discharges will shorten battery life
Connect the UPS power cable directly to a wall outlet. Do not use surge protectors
or extension cords.
bu001b
bu055a
bu 05 7 a
bu059a
bu058a
bu060a
Back-UPS Pro BR1300G / BR1500G2
Connect the Equipment
Battery Backup and Surge Protected outlets
When the Back-UPS is receiving input power, the Battery
Backup with Surge Protection outlets will supply power to
connected equipment. During a power outage or other
utility problems, the Battery Backup outlets receive power
for a limited time from the Back-UPS.
Connect equipment such as printers, FAX machines,
scanners, or other peripherals that do not need battery
backup power to the Surge Protection Only outlets. These
outlets provide Full Time protection from surges even if
the Back-UPS is switched OFF.
Master and Controlled outlets
To conserve electricity, when the device connected to
Master Outlet goes into Sleep or Standby mode, or turns
Off, the Controlled device(s) will shut down as well,
saving electricity.
Connect a master device, such as a desktop computer or
audio/visual receiver to the Master outlet. Connect
peripheral devices such as a printer, speakers, or a scanner
to the Controlled outlets.
USB and Serial Data port To use PowerChute Personal Edition, connect the supplied USB software cable or an optional
serial cable (not supplied).
Ground screw Connect the ground lead of additional surge suppression devices such as network and data line
surge protectors.
Building Wiring Fault
indicator
If this indicator is illuminated, there is a problem with the wiring in the building. Contact an
electrician immediately and do not use the Back-UPS.
Surge Protected outlets,
controlled by the Master
outlet
These outlets are protected from electrical surges, and will disconnect from utility power during
a power outage, or if the Master device goes into Sleep or Standby mode.
Surge Protected outlets These outlets provide Full Time protection from surges, even if the Back-UPS is off. Connect
equipment such as printers and scanners that do not require battery backup protection.
Battery Backup outlets with
Surge Protection
During a power outage or other utility problems, the Battery Backup outlets receive power for a
limited time from the Back-UPS. Connect critical equipment such as desktop computer,
computer monitor, modem or other data sensitive devices into these outlets.
Battery Backup outlets with
Surge Protection, controlled
by the Master outlet
These outlets will supply battery power to the connected equipment during a power outage.
Power will be disconnected to these outlets if the Master device goes into Sleep or Standby
mode. Connect equipment such as a computer monitor to these outlets.
Master outlet Connect the master device to this outlet, in most scenarios, this will be the main computer.
External Battery Pack
connector
Connect an external battery pack to provide additional battery backup runtime (Back-UPS RS
1500 only).
Coaxial ports with surge
protection
Connect a cable modem or other equipment with coaxial jacks.
In/Out Ethernet
surge-protected ports
Use an ethernet cable to connect a cable modem to the IN port, and connect a computer to the
OUT port.
bu103 a
Back-UPS Pro BR1300G / BR1500G 3
Operation
Power Saving Function
To conserve electricity, configure the Back-UPS to recognize a Master device, such as a desktop computer or an A/V
receiver, and Controlled peripheral devices, such as a printer, speakers, or a scanner. When the Master device goes
into Sleep or Standby mode, or is switched OFF, the Controlled device(s) will be switched off as well, saving
electricity.
NOTE: Devices that provide network services such as routers, modems or wireless printers should not be plugged into the
Controlled outlets. This product ships with the Power Saving feature Disabled. To enable this feature follow the instructions
below.
Enable the Power Saving function. Press and hold and MUTE DISPLAY simultaneously for two seconds.
The Back-UPS will beep to indicate that the feature is enabled. The leaf icon on the display will illuminate.
Disable the Power Saving function. Press and hold and simultaneously for two seconds. The Back-UPS MUTE DISPLAY
will beep to indicate that the feature is disabled. The leaf icon on the display will darken.
Setting the threshold. The amount of power used by a device in Sleep or Standby mode varies between devices. It may be
necessary to adjust the threshold at which the Master outlet signals the Controlled outlets to shut down.
1.Ensure a master device is connected to the Master outlet. Put that device into Sleep or Standby mode, or turn it OFF.
2.Press and simultaneously and hold for six seconds, until the leaf icon flashes three times and the Back-UPS DISPLAY MUTE
beeps three times.
3.The Back-UPS will now recognize the threshold level of the Master device and save it as the new threshold setting.
Power Saving Display
The display interface can be configured to be continuously illuminated, or to save energy, it can be configured to darken after a
period of inactivity.
1.Full Time Mode: Press and hold DISPLAY for two seconds. The display will illuminate and the Back-UPS will beep to confirm
the Full Time mode.
2.Power Saving Mode: Press and hold DISPLAY for two seconds. The display will darken and the Back-UPS will beep to confirm
the Power Saving mode. While in Power Saving Mode, the display will illuminate if a button is pressed, it then darkens after 60
seconds of no activity.
Unit Sensitivity
Adjust the sensitivity of the Back-UPS to control when it will switch to battery power; the higher the sensitivity, the more often
the Back-UPS will switch to battery power.
1.Ensure the Back-UPS is connected to utility power, but is OFF.
2.Press and hold the POWER button for six seconds. The bar will flash on and off, indicating that the Back-UPS L COAD APACITY
is in programming mode.
3.Press POWER again to rotate through the menu options. Stop at selected sensitivity. The Back-UPS will beep to conrm the
selection.
Generator Sensitivity Default Sensitive Loads
Low sensitivity Medium sensitivity (Default) High sensitivity
78-150Vac 88-147 Vac 88-144 Vac
Input voltage is extremely low or high.
(Not recommended for computer loads.)
The Back-UPS frequently switches to
battery power.
The connected equipment is
sensitive to voltage fluctuations.


Product specificaties

Merk: Apc
Categorie: UPS
Model: Back-UPS Pro BR1500G

Heb je hulp nodig?

Als je hulp nodig hebt met Apc Back-UPS Pro BR1500G stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding UPS Apc

Handleiding UPS

Nieuwste handleidingen voor UPS